文献速递耳科与耳神经

人工耳蜗使用者对时频谱处理的测量:刺激强度的影响及在线版本的验证

Measurement of Spectro-Temporal Processing by Cochlear Implant Users: Effects of Stimulus Level and Validation of an Online Implementation.
PubMed 文献 · Ear Hear · 2025-06-06

本研究为前瞻性、单盲、两阶段重复测量设计,纳入10例人工耳蜗使用者,评估STRIPES测试在不同扬声器给声强度(50、65、75 dB SPL)下的表现及其与英国CRM测试的关系,并将STRIPES及其在线版本webSTRIPES扩展至Med-El人工耳蜗系统。结果显示给声强度对STRIPES波纹密度阈值及CRM语句SRT70无显著影响,扬声器STRIPES与webSTRIPES阈值显著相关,webSTRIPES重测信度良好至优秀;CRM SRT70与STRIPES阈值的相关方向符合预期但未达统计学显著,可能因样本量小(n=7)限制了检验效能。

要点

  • 给声强度(50、65、75 dB SPL)对STRIPES波纹密度阈值及CRM语句SRT70无显著影响。
  • 扬声器STRIPES与webSTRIPES阈值显著相关,webSTRIPES重测信度良好至优秀。
  • STRIPES和webSTRIPES可在Med-El人工耳蜗系统中可靠测量波纹密度阈值。

核心结论

  • STRIPES和webSTRIPES波纹密度阈值评分可在Med-El人工耳蜗系统中可靠测量,且不受给声强度影响。
  • STRIPES测试是评估成人人工耳蜗使用者结局的有前景工具,无需对调机改变进行长时间适应。

研究设计与样本

  • 前瞻性、单盲、两阶段重复测量研究,纳入10例人工耳蜗使用者。
  • 第一阶包括三个模块:测试前webSTRIPES、三种扬声器给声强度(50、65、75 dB SPL)下的STRIPES、测试后webSTRIPES。
  • 第二阶在与第一阶相同的三种给声强度下测量CRM语句(以时间反转言语为掩蔽)的言语接收阈(SRT70)。

主要发现

  • 给声强度对STRIPES波纹密度阈值或CRM语句SRT70均无显著影响。
  • 扬声器STRIPES与webSTRIPES阈值之间呈显著相关。
  • webSTRIPES显示良好至优秀的重测信度。
  • CRM SRT70与STRIPES阈值的相关方向符合预期,但未达统计学显著,可能因样本量小(n=7)限制了检测有意义关系的效能。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • CRM SRT70与STRIPES阈值的相关未达统计学显著,可能因样本量小(n=7)限制了检测有意义关系的效能。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Evaluating adjustments to cochlear implant (CI) settings is challenging as recipients need time to adapt for optimal speech test performance. The Spectro-Temporal Ripple for Investigating Processor EffectivenesS (STRIPES) test, a language-independent measure of spectro-temporal resolution, has been validated with Advanced Bionics and Cochlear CI systems. This study investigates if performance on the STRIPES test varies with presentation level in a loudspeaker setup and its relationship with outcomes on the British Coordinate Response Measure (CRM) test. In addition, it extends the use of STRIPES and its online version "webSTRIPES" to Med-El CI systems. DESIGN: A prospective, single-blind, two-session repeated-measures study was conducted with 10 CI users. The first session included three blocks: pre-test webSTRIPES, STRIPES at three loudspeaker presentation levels (50, 65, and 75 dB SPL), and post-test webSTRIPES. The second session measured the speech reception threshold (SRT70) for CRM sentences with a time-reversed speech masker, presented at the same three levels. RESULTS: Presentation level did not significantly affect STRIPES ripple density thresholds or SRT70 for CRM sentences. A significant correlation was found between STRIPES loudspeaker and webSTRIPES thresholds. WebSTRIPES showed good-to-excellent test-retest reliability. The correlation between CRM SRT70 and STRIPES thresholds, while in the predicted direction, was not statistically significant, likely due to the small sample size (n = 7), which may have limited the power to detect a meaningful relationship. CONCLUSIONS: STRIPES and webSTRIPES ripple density threshold scores can be reliably measured with Med-El CI systems, unaffected by presentation level. The STRIPES test is a promising tool for assessing adult CI listener outcomes without requiring prolonged acclimatization to programming changes.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Bysouth-Young D, Guérit F, Shahidi L, et al. Measurement of Spectro-Temporal Processing by Cochlear Implant Users: Effects of Stimulus Level and Validation of an Online Implementation. Ear Hear. 2025. PMID: 40474344. doi:10.1097/AUD.0000000000001676

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。