文献速递耳科与耳神经

基于不同峰度调整算法的调整暴露水平分析及其在噪声性听力损失评估中的性能比较

Analysis of Adjusted Exposure Levels Based on Different Kurtosis Adjustment Algorithms and Their Performance Comparison in Evaluating Noise-Induced Hearing Loss.
PubMed 文献 · Ear Hear · 2025-05-08

本研究分析中国制造业4276名工人的个体日噪声记录,比较算术平均、几何平均和分段调整三种峰度调整方案。几何平均(调整系数6.5)与分段调整(调整系数5.4)性能相当且优于算术平均。分段调整更灵活但易受极端值影响,需进一步研究提高准确性和可靠性。

要点

  • 几何平均峰度调整系数为6.5,分段调整系数为5.4,算术平均系数为6.5。
  • 几何平均与分段调整预测NIPTS346性能相当,均优于算术平均。
  • 分段调整更灵活但易受极端值影响,需进一步研究提高准确性和可靠性。

核心结论

  • 使用几何平均(调整系数6.5)或分段调整(调整系数5.4)的峰度调整LAeq,8hr比算术平均更准确评估噪声性听力损失。
  • 分段调整提供更灵活的峰度调整方案,具有更广泛潜在应用前景。
  • 分段调整结果可能受极端值严重影响,需进一步研究提高准确性和可靠性。

研究设计与样本

  • 研究分析中国制造业4276名工人的个体日噪声记录。
  • 以60秒为计算窗口长度,无重叠计算每个窗口的噪声峰度。
  • 采用算术平均(方案1)和几何平均(方案2)算法计算班次长时间噪声的峰度。
  • 方案3(分段调整算法)每60秒同时确定峰度和A计权声压级(LAeq,60sec),对每个LAeq,60sec进行峰度调整,再对480个一分钟调整后的LAeq,60sec值进行对数平均得到峰度调整LAeq,8hr。
  • 队列按峰度水平分为三组,分组取决于计算班次长时间噪声峰度的方法(算术或几何平均)。

主要发现

  • 多元线性回归分析算术平均和几何平均分类的噪声峰度数据,计算出的调整系数分别为6.5和7.6。
  • 多层感知机回归确定分段调整中的最优系数,系数值为5.4。
  • 使用Lempert模型评估NIPTS346预测性能,基于几何平均算法(方案2)和分段调整(方案3)的峰度调整性能相当,且远优于算术平均算法。

局限性

  • 分段调整的结果可能受极端值严重影响。
  • 需要进一步研究以提高分段调整的准确性和可靠性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Kurtosis is an essential metric in evaluating hearing loss caused by complex noise, which is calculated from the fourth central moment and the SD of the noise signal. Previous studies have shown that kurtosis-adjusted noise exposure levels can more accurately predict hearing loss caused by various types of noise. There are three potential kurtosis adjustment schemes: arithmetic averaging, geometric averaging, and segmented adjustment. This study evaluates which kurtosis adjustment scheme is most practical based on the data collected from industrial settings. DESIGN: This study analyzed individual daily noise recordings collected from 4276 workers in manufacturing industries in China. Using 60 sec as the calculation window length, each window's noise kurtosis was calculated without overlap. Then, the arithmetic averaging (Scheme 1) and geometric averaging (Scheme 2) algorithms were used to calculate the kurtosis of the shift-long noise. Eventually, the kurtosis-adjusted 8 h working day exposure level ( LAeq,8hr ) was obtained using the kurtosis-adjusted formula. In Scheme 3 (i.e., segmented adjustment algorithm), kurtosis was determined per 60 sec simultaneously with A-weighted sound pressure level ( LAeq,60sec ). Kurtosis adjustment was applied on LAeq,60sec every 60 sec. Then, the kurtosis-adjusted LAeq,8hr was calculated by log-averaging of 480 one-minute-adjusted LAeq,60sec values. The cohort was divided into three groups according to the level of kurtosis. Which group the participants belonged to depended on the method used to calculate the shift-long noise kurtosis (i.e., arithmetic or geometric averaging). Noise-induced hearing loss was defined as noise-induced permanent threshold shift at frequencies 3, 4, and 6 kHz (NIPTS 346 ). Predicted NIPTS 346 was calculated using the ISO 1999 model or Lempert's model for each participant, and the actual NIPTS 346 was determined by correcting for age and sex using non-noise-exposed Chinese workers (n = 1297). A dose-effect relationship for three kurtosis groups was established using the NIPTS 346 and kurtosis-adjusted LAeq,8hr . The performance of three kurtosis adjustment algorithms was evaluated by comparing the estimated marginal mean of the difference between estimated NIPTS 346 by ISO 1999 or estimated NIPTS 346 by Lempert's model and actual NIPTS 346 in three kurtosis groups. RESULTS: Multiple linear regression was used to analyze the noise kurtosis classified data obtained by arithmetic and geometric averaging, and the calculated adjustment coefficients were 6.5 and 7.6, respectively. Multilayer perceptron regression was used to identify the optimal coefficients in the segmented adjustment, resulting in a coefficient value of 5.4. These three adjustment schemes were used to evaluate the performance of NIPTS 346 prediction using Lempert's model. The kurtosis adjustment based on the geometric averaging algorithm (Scheme 2) and on the segmented adjustment (Scheme 3) demonstrated comparable performance and was much better than the arithmetic averaging algorithm. CONCLUSIONS: Evidence in this study indicated that using the kurtosis-adjusted LAeq,8hr by geometric averaging with an adjustment coefficient of 6.5 or by segmented adjustment with an adjustment coefficient of 5.4 could more accurately evaluate noise-induced hearing loss than by arithmetic averaging. The segmented adjustment provided a more flexible kurtosis adjustment scheme with a broader potential application prospect. However, the results of segmented adjustment can be severely affected by extreme values, and further research is needed to improve the accuracy and reliability of the segmented adjustment.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Liu H, Zhang M, Sun X, et al. Analysis of Adjusted Exposure Levels Based on Different Kurtosis Adjustment Algorithms and Their Performance Comparison in Evaluating Noise-Induced Hearing Loss. Ear Hear. 2025. PMID: 40336150. doi:10.1097/AUD.0000000000001674

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。