切换乐器如何影响人工耳蜗使用者的音高辨别
研究纳入15名成人人工耳蜗使用者和15名已知听力正常的同龄人,在A2、A3、A4、A5四个音域测量钢琴与次中音萨克斯管的音高辨别,包括跨乐器切换条件。两组切换乐器后辨别阈值均约差2倍,组间切换附加困难无显著差异;但人工耳蜗使用者倾向把萨克斯管判为更高音,且在A5附近受切换影响显著更大。
要点
- 两组切换乐器后音高辨别阈值均约差2倍,切换所致附加困难组间无显著差异。
- 人工耳蜗使用者倾向把次中音萨克斯管判为比钢琴音高更高,听力正常组无此偏向。
- 人工耳蜗使用者在A5音域受乐器切换影响显著更大,作者认为可能反映人工耳蜗对基频时间编码较差。
核心结论
- 乐器切换对音高分辨率的影响幅度在人工耳蜗使用者与已知听力正常同龄人间相似,但人工耳蜗使用者存在把次中音萨克斯管判为更高音高的偏向,且在A5附近受切换影响显著更大,作者认为这可能反映人工耳蜗对基频时间编码较差。
研究设计与样本
- 研究为成人对照研究,纳入15名人工耳蜗使用者和15名已知听力正常的同龄人,在钢琴与次中音萨克斯管上测量音高辨别,包括跨乐器音高比较条件。
- 音高辨别在A2(110 Hz)、A3(220 Hz)、A4(440 Hz)、A5(880 Hz)为中心的4个音域测量;乐器切换效应以有无切换时辨别阈值的变化量化。
- 采用方差分析和Spearman秩相关分别检验组间差异与相关结局。
主要发现
- 人工耳蜗使用者音高辨别较差,但乐器切换带来的附加困难在两组间无显著差异。
- 两组在切换乐器时的辨别阈值均约为不切换时的2倍。
- 人工耳蜗使用者倾向把次中音萨克斯管判为比钢琴音高更高,已知听力正常者无此偏向。
- 人工耳蜗使用者在A5音域受乐器切换影响显著更大。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Cochlear implant (CI) users struggle with music perception. Generally, they have poorer pitch discrimination and timbre identification than peers with normal hearing, which reduces their overall music appreciation and quality of life. This study's primary aim was to characterize how the increased difficulty of comparing pitch changes across musical instruments affects CI users and their peers with no known hearing loss. The motivation is to better understand the challenges that CI users face with polyphonic music listening. The primary hypothesis was that CI users would be more affected by instrument switching than those with no known hearing loss. The rationale was that poorer pitch and timbre perception through a CI hinders the disassociation between pitch and timbre changes needed for this demanding task. DESIGN: Pitch discrimination was measured for piano and tenor saxophone including conditions with pitch comparisons across instruments. Adult participants included 15 CI users and 15 peers with no known hearing loss. Pitch discrimination was measured for 4 note ranges centered on A2 (110 Hz), A3 (220 Hz), A4 (440 Hz), and A5 (880 Hz). The effect of instrument switching was quantified as the change in discrimination thresholds with and without instrument switching. Analysis of variance and Spearman's rank correlation were used to test group differences and relational outcomes, respectively. RESULTS: Although CI users had worse pitch discrimination, the additional difficulty of instrument switching did not significantly differ between groups. Discrimination thresholds in both groups were about two times worse with instrument switching than without. Further analyses, however, revealed that CI users were biased toward ranking tenor saxophone higher in pitch compared with piano, whereas those with no known hearing loss were not so biased. In addition, CI users were significantly more affected by instrument switching for the A5 note range. CONCLUSIONS: The magnitude of the effect of instrument switching on pitch resolution was similar for CI users and their peers with no known hearing loss. However, CI users were biased toward ranking tenor saxophone as higher in pitch and were significantly more affected by instrument switching for pitches near A5. These findings might reflect poorer temporal coding of fundamental frequency by CIs.
引用
- O'Connell SR, Bissmeyer SRS, Gan H, et al. How Switching Musical Instruments Affects Pitch Discrimination for Cochlear Implant Users. Ear Hear. 2025. PMID: 40325511. doi:10.1097/AUD.0000000000001640
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。