双侧与单侧聋人工耳蜗植入者在新型噪声下言语与定位任务中的比较
这项非随机前瞻性人体研究在三级学术医疗中心比较了双侧人工耳蜗植入者(BiCI)、单侧聋人工耳蜗使用者(SSDCI)和正常听力对照者在变信噪比下的噪声下言语(SIN)与声源定位表现,并用电磁头动追踪监测头部运动。结果显示BiCI定位准确性低于对照但高于SSDCI,SSDCI的SIN表现持续优于BiCI,且SSDCI与对照在任何噪声条件下均无统计学显著差异。
要点
- BiCI定位准确性低于正常听力对照,但高于SSDCI。
- SSDCI的SIN表现持续优于BiCI,与对照在任何噪声条件下均无统计学显著差异。
- BiCI较SSDCI更早启动头动,所有人工耳蜗使用者的绝对位移均大于对照。
核心结论
- 在定位与SIN两组双耳任务中,表现最差的并非同一组:SSDCI噪声下言语理解更好,而BiCI空间定位表现更好。
- 单耳保留的声学听力并未在所有任务上带来优势,研究凸显人工耳蜗使用者适应性行为的复杂交互。
研究设计与样本
- 非随机、前瞻性人体研究,在三级学术医疗中心开展。
- 受试者在暗室半消声室中听取不同信噪比的哈佛IEEE句子,并用电磁头动追踪系统监测头部运动。
- 结局包括头部运动模式、定位准确性和SIN表现;分组为BiCI、SSDCI和正常听力对照。
主要发现
- BiCI定位目标不如对照准确且随信噪比变化更大,但比SSDCI更准确。
- SIN方面SSDCI持续优于BiCI,SSDCI与对照在任何噪声条件下均无统计学显著差异。
- 跨信噪比BiCI均比SSDCI更早启动头动,对照的可预测延迟最小。
- 所有人工耳蜗使用者的总体绝对位移均大于对照。
- BiCI位移大于SSDCI,但其模式与对照相似,信噪比越有利所需运动越少。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: This study investigated how individuals who have undergone bilateral cochlear implantations (BiCIs) use compensatory head movements to optimize sound localization and speech-in-noise (SIN) performance compared with single-sided deaf users of cochlear implant (SSDCI) and normal hearing controls. STUDY DESIGN: Nonrandomized, prospective human-subject study. SETTING: Tertiary academic medical center. METHODS: Subjects were presented with Harvard IEEE sentences at varying signal-to-noise ratios (SNRs) in a darkened, semianechoic chamber. An electromagnetic head-tracking system monitored head movement. Outcomes included head movement patterns, localization accuracy, and SIN performance. RESULTS: BiCI localized targets less accurately with higher SNR-dependent variability than controls, but with greater accuracy than SSDCI. For SIN, SSDCI consistently showed superior performance to the BiCI, with no statistical significance found at any noise condition between SSDCI and controls. Across SNR, BiCI consistently initiated head movements more promptly compared to SSDCI, with controls predictably exhibiting the least delay. All CI recipients exhibited greater absolute displacement overall compared to controls. Although BiCI showed greater displacement compared to SSDCI, their pattern resembled controls, with decreased movement necessary as SNR became more favorable. CONCLUSION: When comparing performance for localization and SIN across groups, the same impaired group does not perform most poorly at both binaural tasks; although SSDCI users maintain better speech understanding in noise, BiCIs tend to perform better on locating stimuli in space. Preserved acoustic hearing in one ear does not provide a performance advantage across all tasks. The study underscores the intricate interplay of adaptive behaviors in CI users, showcasing successes and challenges in optimizing binaural hearing performance.
引用
- Abdulrazzak O, Ibrahim NI, Jones G, et al. Comparing Bilateral and Single-Sided Deaf Cochlear Implant Recipients in a Novel Speech-in-Noise and Localization Task. Otolaryngol Head Neck Surg. 2025. PMID: 40062650. doi:10.1002/ohn.1187