特纳综合征患者咽鼓管特征的CT影像学分析
本研究比较特纳综合征(TS)患者与年龄匹配对照儿童的咽鼓管(ET)角度、长度及骨段、骨-软骨交界、咽口的直径,并分析TS患者发生咽鼓管功能障碍(ETD)的潜在危险因素。结果显示TS组ET角度更小,骨段、骨-软骨交界及咽口直径均显著更窄;TS患者中ET角度<33.25°、骨段直径<0.355 cm、咽口直径<0.15 cm与ETD风险增加显著相关。结论认为更水平的ET角度及更窄的各段直径可能促发TS患者的ETD,建议对TS儿童加强听力学监测并早期干预。
要点
- TS组咽鼓管角度为31.57°(95%CI 30.05-33.09),小于对照组33.72°(95%CI 32.68-34.75),p=0.019。
- TS组咽鼓管骨段直径0.30 cm、骨-软骨交界0.15 cm、咽口0.14 cm,均较对照组显著更窄(p=0.001)。
- TS患者中ET角度<33.25°、骨段直径<0.355 cm、咽口直径<0.15 cm与ETD风险增加显著相关。
核心结论
- 更水平的咽鼓管角度及各段更窄的直径可能促发特纳综合征患者的咽鼓管功能障碍。
- 建议对特纳综合征儿童加强听力学监测并采取早期干预策略。
研究设计与样本
- 本研究比较特纳综合征患者与对照儿童的咽鼓管角度、长度及骨段、骨-软骨交界、咽口直径,并对TS患者进行亚组分析以探索ETD的潜在危险因素。
- 研究注册号为ChiCTR2300068063(https://www.chictr.org.cn/)。
主要发现
- TS组咽鼓管角度为31.57°(95%CI 30.05-33.09),显著小于对照组33.72°(95%CI 32.68-34.75),p=0.019。
- 两组咽鼓管长度无显著差异。
- TS组咽鼓管骨段直径为0.30 cm(95%CI 0.29-0.32),较对照组显著更窄,p=0.001。
- TS组骨-软骨交界直径为0.15 cm(95%CI 0.13-0.16),较对照组显著更窄,p=0.001。
- TS组咽口直径为0.14 cm(95%CI 0.13-0.16),较对照组显著更窄,p=0.001。
关键数值与推荐
- TS患者中咽鼓管角度<33.25°与ETD风险增加显著相关。
- TS患者中骨段直径<0.355 cm与ETD风险增加显著相关。
- TS患者中咽口直径<0.15 cm与ETD风险增加显著相关。
临床怎么用
- 作者建议对特纳综合征儿童加强听力学监测并采取早期干预策略。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Patients with Turner syndrome (TS) commonly experience acute otitis media and Eustachian tube dysfunction (ETD). Comparison of the anatomical features of the Eustachian tube (ET) between TS patients and age-matched controls may provide insights into the high prevalence of ETD in TS. METHODS: This study compared the ET angle, length, and diameters of the bone segment, bone-cartilage (BC) junction, and pharyngeal opening between TS patients and control children. A subgroup analysis was also conducted to explore potential risk factors for ETD in TS patients. RESULTS: The ET angle in the TS group was significantly smaller (31.57°; 95% confidence interval [95% CI]: 30.05-33.09) compared with the control group (33.72°; 95% CI: 32.68-34.75; p = 0.019). No significant difference in ET length was observed between the two groups. However, the TS group exhibited significantly narrower diameters at the bony segment of the ET (0.30 cm; 95% CI: 0.29-0.32; p = 0.001), the BC junction (0.15 cm; 95% CI: 0.13-0.16; p = 0.001), and the pharyngeal orifice (0.14 cm; 95% CI: 0.13-0.16; p = 0.001) compared with the control group. Correlation analysis revealed a significant positive correlation between ET length and angle in the control group, whereas a non-significant negative correlation was observed in the TS group. In patients with TS, ET angles < 33.25°, bone segment diameters < 0.355 cm, and pharyngeal diameters < 0.15 cm were significantly associated with an increased risk of ETD. CONCLUSION: A more horizontal ET angle, along with narrower diameters at various ET segments, may contribute to the development of ETD in patients with TS. Consequently, heightened vigilance in monitoring hearing and early intervention strategies is recommended for children with TS (https://www.chictr.org.cn/, ChiCTR2300068063).
引用
- Huang Y, Liang L, Zhang L, et al. Eustachian Tube Characteristics in Patients With Turner Syndrome: A CT-Based Radiological Analysis. Laryngoscope. 2025. PMID: 39976358. doi:10.1002/lary.32086
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。