头颈部重建静脉吻合中的微血管耦合器:系统综述与Meta分析
该系统综述与Meta分析比较了头颈部重建中静脉吻合使用耦合器与手工缝合技术的效果,纳入52项研究的14,053例患者、14,270例游离皮瓣。耦合器组静脉血栓率(OR 1.06,95%CI 0.65-1.72)和再手术率(OR 0.93,95%CI 0.51-1.70)与手工缝合组无显著差异,但失败率显著更低(OR 0.34,95%CI 0.20-0.58)。静脉吻合时间(MD -20.5,95%CI -51.7至10.7)和总手术时间(MD -23.7,95%CI -344.3至296.8)在耦合器组呈非显著降低。
要点
- 耦合器组与手工缝合组静脉血栓率无显著差异(OR 1.06,95%CI 0.65-1.72)。
- 耦合器组失败率显著低于手工缝合组(OR 0.34,95%CI 0.20-0.58)。
- 两种技术总体结局均优良,吻合技术选择应基于外科医生偏好。
核心结论
- 尽管静脉耦合器观察到轻微优势,但两种技术的总体结局均优良,吻合技术的选择应以外科医生偏好为指导。
研究设计与样本
- 系统综述与Meta分析,纳入回顾性和前瞻性队列研究,检索PubMed/MEDLINE和Scopus,并手动检索Google Scholar和参考文献列表。
- 共纳入52项研究,14,053例患者接受14,270例头颈部游离皮瓣重建。
主要发现
- 耦合器组静脉血栓率与手工缝合组无显著差异(OR 1.06,95%CI 0.65-1.72)。
- 耦合器组再手术率与手工缝合组无显著差异(OR 0.93,95%CI 0.51-1.70)。
- 耦合器组失败率显著低于手工缝合组(OR 0.34,95%CI 0.20-0.58)。
- 耦合器组静脉吻合时间呈非显著降低(MD -20.5,95%CI -51.7至10.7)。
- 耦合器组总手术时间呈非显著降低(MD -23.7,95%CI -344.3至296.8)。
关键数值与推荐
- 6080例皮瓣采用耦合器进行静脉吻合,8190例皮瓣采用手工缝合技术。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: We conducted a systematic review and meta-analysis to compare venous couplers and hand-sewn techniques for venous anastomosis in head and neck reconstruction. DATA SOURCES: PubMed/MEDLINE and Scopus, databases were searched for relevant publications. Additionally, a manual search was performed in Google Scholar and through reference lists. REVIEW METHODS: Retrospective and prospective cohort studies were included. Odds ratios (ORs) and mean differences (MD) were calculated with their 95% confidence intervals (CIs) for each study comparing the 2 groups (coupler vs hand). The inverse variance method was used to combine the effect sizes from the individual studies. RESULTS: A total of 14,053 patients undergoing 14,270 head and neck free flap reconstructions were included from 52 studies. A total of 6080 flaps were performed using a coupling device for the venous anastomoses, while 8190 flaps were performed with the hand-sewn technique. No significant difference was found for the venous thrombosis rate (OR: 1.06, 95% CI: 0.65-1.72), and reoperation rate (OR: 0.93, 95% CI: 0.51-1.70), but a significantly lower failure rate was measured for the coupler group (OR = 0.34, 95% CI: 0.20-0.58). A nonsignificant lower operative time was found for venous anastomoses (MD: -20.5, 95% CI: -51.7 to 10.7) and total surgery (MD: -23.7, 95% CI: -344.3 to 296.8) for the coupler group. CONCLUSION: Despite the slight advantages observed with venous couplers, the overall outcomes of both techniques are excellent, and the choice of anastomotic technique should be guided by surgeon preference.
引用
- Costantino A, Uralov D, Festa BM, et al. Microvascular Coupling in Venous Anastomoses for Head and Neck Reconstruction: A Systematic Review and Meta-Analysis. Otolaryngol Head Neck Surg. 2025. PMID: 39981870. doi:10.1002/ohn.1167
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。