文献速递耳科与耳神经

评估不同纯音平均值对人工耳蜗候选资格筛查的影响

Evaluating the Effect of Various Pure Tone Averages on Cochlear Implant Candidacy Screening.
PubMed 文献 · Laryngoscope · 2025-01-21

本研究基于三级医疗中心2014至2024年完成助听后言语测试的成人数据,比较低频、高低频、高频及扩展频率纯音平均值预测人工耳蜗候选者的准确性。结果显示高低频纯音平均值在AzBio和CNC结局下灵敏度最高,显著优于低频纯音平均值;低频纯音平均值特异度最佳。结论认为扩展频率纯音测听较传统低频纯音平均值筛查灵敏度更高。

要点

  • 高低频纯音平均值预测人工耳蜗候选者的灵敏度最高,AzBio结局为96.3%,CNC结局为95.6%。
  • 低频纯音平均值特异度最佳,AzBio结局为63.6%,CNC结局为76.9%。
  • 高低频纯音平均值灵敏度显著优于低频纯音平均值(p < 0.001)。

核心结论

  • 扩展频率纯音测听在预测人工耳蜗候选者方面较传统低频纯音平均值灵敏度更高。
  • 采用更宽频率范围的纯音平均值筛查将使更多患者被识别为需进行人工耳蜗评估。

研究设计与样本

  • 研究纳入2014年至2024年间在三级医疗中心完成人工耳蜗评估中助听后言语测试的成人。
  • 以个体耳的助听后AzBio或助听后CNC得分为结局,评估低频、高频、高低频及扩展频率纯音平均值,采用配对研究设计比较灵敏度、特异度、阴性预测值和阳性预测值。
  • 以AzBio为结局变量共675例观察来自363例患者,以CNC为结局变量共665例观察来自364例患者。

主要发现

  • 高低频纯音平均值在AzBio结局下灵敏度为96.3%,在CNC结局下为95.6%,均显著优于低频纯音平均值(p < 0.001)。
  • 低频纯音平均值在AzBio结局下特异度为63.6%,在CNC结局下为76.9%,为各纯音平均值中最佳。

关键数值与推荐

  • 高低频纯音平均值灵敏度:AzBio结局96.3%,CNC结局95.6%。
  • 低频纯音平均值特异度:AzBio结局63.6%,CNC结局76.9%。
  • 高低频纯音平均值灵敏度显著优于低频纯音平均值(p < 0.001)。

临床怎么用

  • 原文结论指出,采用扩展频率纯音测听筛查可提高识别需人工耳蜗评估患者的灵敏度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To provide evidence to use an extended frequency pure tone average to screen for cochlear implant evaluation candidates as recommended by the American Cochlear Implant Alliance. Additionally, to determine whether traditional low frequency, high or low frequency, high frequency, or extended frequency pure tone average most accurately predicts cochlear implant candidates based on speech perception scores from aided AzBio sentence testing or aided consonant-nucleus-consonant (CNC) testing. METHOD: Adults from a tertiary care center who completed aided sentence testing during cochlear implant evaluation between 2014 and 2024 were assessed. Pure tone averages at low, high, low or high, and extended frequency ranges were evaluated with individual ear's aided AzBio or aided CNC scores as an outcome. Sensitivity, specificity, negative predictive value, and positive predictive value were assessed and compared using a paired study design. RESULTS: There were 675 observations from 363 patients with AzBio as an outcome variable and 665 observations from 364 patients with CNC scores as an outcome variable. High or low frequency achieved the highest sensitivity at 96.3% AzBio as an outcome and 95.6% with CNC as an outcome, which was significantly better than low frequency (p < 0.001). Low frequency achieved the best specificity at 63.6% with AzBio as an outcome 76.9% with CNC as an outcome. CONCLUSION: Extended frequency pure tones resulted in greater sensitivity in predicting CI candidates compared with the traditionally used low frequency pure tone average. Screening with wider frequency values will lead to a greater number of patients being identified for a cochlear implant evaluation. LEVEL OF EVIDENCE: 3 Laryngoscope, 135:2100-2106, 2025.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. Greiner RC, Raghavan AM, Lipschitz N, et al. Evaluating the Effect of Various Pure Tone Averages on Cochlear Implant Candidacy Screening. Laryngoscope. 2025. PMID: 39835656. doi:10.1002/lary.32018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。