双耳间潜伏期与频率失配对双模式人工耳蜗使用者言语识别的影响
研究纳入12名双模式使用至少1年的成人,评估潜伏期失配校正及频率失配对掩蔽句识别的影响。结果显示潜伏期小或匹配时表现显著更好,向助听器耳侧掩蔽配置约提升10%;频率失配每增加1个半音,表现下降2%;潜伏期与频率失配交互作用不显著。作者认为双模式使用者可能受益于个体化验配以匹配潜伏期并最小化频率失配。
要点
- 潜伏期失配小或匹配时言语识别显著更好,助听器耳侧掩蔽配置约提升10%。
- 频率失配每增加1个半音,言语识别表现下降2%。
- 潜伏期与频率失配的交互作用不显著,潜伏期匹配获益在频率失配范围内近似叠加。
核心结论
- 双耳间潜伏期和频率失配即使长期设备使用后仍可观察到不利影响。
- 这些初步结果提示双模式人工耳蜗使用者可能受益于个体化验配,即匹配设备间潜伏期并最小化人工耳蜗的频率失配。
研究设计与样本
- 研究纳入12名双模式使用至少1年的成人,评估潜伏期失配与匹配条件下的表现。
- 在10人掩蔽语下评估掩蔽句识别,测试三种空间配置:目标在前方且掩蔽声同向、掩蔽声向人工耳蜗耳侧90°、掩蔽声向助听器耳侧90°。
- 最顶端电极(E1)的频率失配由术后影像和熟悉人工耳蜗映射的滤波频率分配确定。
主要发现
- 当设备间潜伏期失配小或匹配时,受试者表现显著更好,在掩蔽声向助听器耳侧的配置中约提升10%。
- 频率失配幅度较大时表现显著更差,失配每增加1个半音偏差,表现下降2%。
- 潜伏期与频率失配的交互作用不显著,提示潜伏期匹配的获益在频率失配范围内近似叠加。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Bimodal cochlear implant (CI) users vary in speech recognition outcomes. This variability may be influenced partly by the CI and contralateral hearing aid (HA) programming procedures, which can result in mismatches in latency and frequency. We assessed the performance of bimodal listeners when latency mismatches were corrected and analyzed how frequency mismatches influenced outcomes. METHODS: Twelve adults with at least 1 year of bimodal use were evaluated in latency mismatched versus matched conditions. Masked sentence recognition was assessed in a 10-talker masker for three spatial configurations: target from the front and the masker either co-located, 90° toward the CI-ear, or 90° toward the HA-ear. Frequency mismatch for the most apical electrode (E1) was determined from postoperative imaging and the filter frequency assignment of their familiar CI map. RESULTS: Participants had significantly better performance when latency mismatches were small or matched between the devices, with an approximately 10% improvement in the configuration with the masker toward the HA-ear. Significantly, poorer performance was observed with larger magnitudes of frequency mismatch, with a 2% drop in performance for every one semitone deviation increase in mismatch. The interaction between latency and frequency mismatch was nonsignificant, suggesting that the benefit of latency matching was approximately additive across the range of frequency mismatches. CONCLUSIONS: Detrimental effects of interaural mismatches in latency and frequency were observed, even after long-term device use. These preliminary results suggest that bimodal CI users might benefit from individualized fitting procedures that match latency across devices and minimize frequency mismatch for the CI. LEVEL OF EVIDENCE: 3 Laryngoscope, 135:2139-2145, 2025.
引用
- Dillon MT, Buss E, Richter ME, et al. Effects of Interaural Latency and Frequency Mismatch on Speech Recognition for Bimodal Cochlear Implant Users. Laryngoscope. 2025. PMID: 39871523. doi:10.1002/lary.32026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。