改善人工耳蜗植入术中的实时反馈:听神经神经音/耳蜗微音电位比值
研究纳入28例植入术中已知耳蜗微音电位(CM)下降的成人人工耳蜗候选者,评估听神经神经音(ANN)与CM比值在CM下降时的变化能否区分真假阳性。结果显示ANN/CM比值升高的19例随访听力损失中位数13.3 dB,显著优于比值下降的9例29.0 dB(p=0.004)。
要点
- ANN/CM比值在CM下降时升高者术后听力损失中位数13.3 dB,比值下降者为29.0 dB(p=0.004)。
- 仅用ANN幅度变化分组时,ANN升高组听力保留中位数12.9 dB,优于ANN下降组25 dB(p=0.02)。
- ANN/CM比值下降组植入后即刻最大CM幅度为植入过程中最大幅度的98%,比值升高组为164%。
核心结论
- ANN/CM比值可区分导致残余听力损失的CM下降与不导致听力损失的CM下降。
- ANN/CM比值测量简便且在CM下降时快速响应,显示出改善术中监测的临床前景。
研究设计与样本
- 从更大数据集中选取28例植入术中已知CM下降的成人人工耳蜗候选者。
- 患者来自8个国际植入中心,计划接受Cochlear Nucleus人工耳蜗(slim-straight或slim-modiolar电极阵列)。
- 植入耳术前500、750、1000 Hz低频平均听阈≤80 dB HL。
- 术后及植入后4至6周行纯音测听,植入过程中及即刻行耳蜗电图检查,刺激为500 Hz、6毫秒纯音短声、110 dB HL。
主要发现
- 28例中19例CM下降期间ANN/CM比值升高,9例下降。
- 随访时ANN/CM比值下降组听力损失中位数29.0 dB,显著差于比值升高组的13.3 dB(p=0.004)。
- 仅按ANN幅度变化分组时,ANN下降组17例、ANN升高组6例,5例在CM下降期间ANN不可测。
- ANN升高组听力保留中位数12.9 dB,显著优于ANN下降组的25 dB(p=0.02)。
- ANN/CM比值下降组植入后即刻最大CM幅度为植入过程中最大幅度的98%(均值),比值升高组为164%(均值)。
临床怎么用
- 原文结论认为ANN/CM比值易于测量且在CM下降时快速响应,显示出改善当前及发展中术中监测方法的临床前景。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Real-time monitoring of cochlear function to predict the loss of residual hearing after cochlear implantation is now possible. Current approaches monitor the cochlear microphonic (CM) during implantation from the electrode at the tip of the implant. A drop in CM response of >30% is associated with poorer hearing outcomes. However, there is prior evidence that CM amplitude can fluctuate in a manner unrelated to hearing trauma, leading to false positives. By monitoring another cochlear response, the auditory nerve neurophonic (ANN), a differentiation between CM drops that result in reduced cochlear output from false positives may be possible. The hypothesis tested in the present work was that ANN/CM ratios measured during a CM drop will increase during drops not associated with postoperative hearing loss. DESIGN: Twenty-eight adult participants with known CM drops during implantation were taken from a larger data set. This contains adult cochlear implant candidates scheduled to receive a Cochlear Nucleus cochlear implant with either the slim-straight or slim-modiolar electrode array with preoperative audiometric low-frequency average thresholds of ≤80 dB HL at 500, 750, and 1000 Hz in the ear to be implanted. Patients were recruited from eight international implant sites. Pure-tone audiometry was measured postoperatively and 4 to 6 weeks after implantation. Electrocochleography was measured during and immediately after the implantation of the array in response to a 500-Hz, 6-msec pure-tone pip at 110 dB HL. RESULTS: The ANN/CM ratio rose during CM drops in 19 of these patients and decreased in 9. At the follow-up timepoint, patients with a decreasing ANN/CM ratio had a median hearing loss of 29.0 dB, significantly worse than the group with increasing ratio at 13.3 dB ( p = 0.004). Considering only the change in ANN amplitude during a CM drop led to smaller groups (ANN drop during CM drop N = 17, ANN increasing during CM drop N = 6) due to 5 patients having undetectable ANN during the CM drop. Using the ANN alone also led to as poorer prediction of hearing preservation, with median hearing preservation in the ANN increasing group of 12.9 dB, significantly better than the ANN decreasing group of 25 dB ( p = 0.02). The group with a decreasing ANN/CM ratio had maximum CM amplitude immediately after insertion lower than the maximum amplitude reached during insertion (mean maximum postinsertion amplitude of 98% of during-insertion amplitude). In comparison, the ANN/CM ratio increasing group tended to have a larger CM amplitude immediately after insertion (mean maximum CM amplitude postinsertion of 164% of the maximum during-insertion amplitude). CONCLUSIONS: These data show that the ANN/CM ratio is a measure that can differentiate between patients with CM drops that lead to a loss of residual hearing and those that do not. The ANN/CM ratio is easily measured and responds rapidly during a CM drop, showing clinical promise for improving current and developing approaches to intraoperative monitoring.
引用
- Bester C, O'Leary SJ, Venail F, et al. Improving Real-Time Feedback During Cochlear Implantation: The Auditory Nerve Neurophonic/Cochlear Microphonic Ratio. Ear Hear. 2025. PMID: 39789698. doi:10.1097/AUD.0000000000001613
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。