文献速递咽喉与嗓音

声门图像采集的评分者间与评分者内可靠性:一种量化声带弓形变的移动应用

Inter-rater and Intra-rater Reliability of Glottal Image Capture: A Mobile Application to Quantify Vocal Fold Bowing.
PubMed 文献 · Laryngoscope · 2024-12-09

本研究评估移动应用GlottIC量化年龄相关声带萎缩所致声带弓形变的可靠性。10名评分者独立使用GlottIC对10例患者的声带动态图像计算弓形变指数(BI),评分者内可靠性强(r=0.822,p<0.001),评分者间ICC为0.720(95%CI: 0.579-0.852),专家ICC为0.808(95%CI: 0.678-0.906),新手ICC为0.651(95%CI: 0.468-0.816)。GlottIC与手动计算BI呈正相关(r=0.811,p<0.001)。

要点

  • GlottIC量化声带弓形变的评分者内可靠性强(r=0.822,p<0.001)。
  • 评分者间一致性良好(ICC=0.720;95%CI: 0.579-0.852)。
  • 专家ICC(0.808)高于新手ICC(0.651),GlottIC与手动BI正相关(r=0.811)。

核心结论

  • GlottIC是一种可靠的移动应用,可在年龄相关声带萎缩患者中以高的评分者内和评分者间可靠性量化声带弓形变。

研究设计与样本

  • 10名评分者独立使用GlottIC从10例年龄相关声带萎缩患者的声带动态图像中量化弓形变指数(BI)。
  • 图像100%重复以分析评分者内可靠性(Pearson相关),评分者间可靠性用组内相关系数(ICC)评估,并分析GlottIC与ImageJ手动计算的相关性。

主要发现

  • 总BI的评分者内可靠性强(r=0.822,p<0.001)。
  • BI的评分者间ICC为0.720(95%CI: 0.579-0.852),提示评分者间一致性良好。
  • 专家ICC为0.808(95%CI: 0.678-0.906),高于新手ICC的0.651(95%CI: 0.468-0.816)。
  • GlottIC与手动BI呈正相关(r=0.811,p<0.001)。
  • 随着BI增加,基于视觉感知评级的弓形变严重程度也增加(p<0.001)。

局限性

  • 通过更稳健的评分者培训和自动化技术可能进一步提高可靠性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Age-related vocal atrophy (ARVA) causes vocal fold bowing, impacting communication and quality of life. The assessment of vocal fold bowing is largely subjective. Glottal Image Capture (GlottIC) is a new mobile application that helps quantify vocal fold bowing. We aim through this study to assess its reliability, compare it to manual calculation method, and compare differences between visual-perceptual bowing severity ratings. METHODS: Ten raters independently quantified Bowing Index (BI) using GlottIC from 10 videostroboscopic images among individuals with ARVA. There was 100% duplication of images to facilitate intra-rater reliability analyses using Pearson's correlation. Inter-rater reliability was quantified using Intraclass Correlation Coefficient (ICC) for experienced and novice raters. The correlation between manual calculations using ImageJ and GlottIC was analyzed. RESULTS: The intra-rater reliability for total BI was strong (r = 0.822, p < 0.001). The inter-rater reliability for BI, calculated using ICC, was (ICC = 0.720; 95% CI: 0.579-0.852), indicating good consistency among the raters. Experts had higher ICC (ICC = 0.808; 95% CI: 0.678-0.906) compared to novice raters (ICC = 0.651; 95% CI: 0.468-0.816). There was a positive correlation between GlottIC and manual BI (r = 0.811, p < 0.001). As the BI increased, the bowing severity, based on visual-perceptual ratings, also increased (p < 0.001). CONCLUSION: GlottIC is a reliable mobile application that can quantify vocal fold bowing in patients with ARVA with high intra- and inter-rater reliability. GlottIC BI measurments are highly correlated with manual BI and visual-perceptual ratings of bowing severity. Further improvements in reliability may be achieved with more robust rater training and automated technologies. LEVEL OF EVIDENCE: 3 Laryngoscope, 135:1732-1736, 2025.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. Aboueisha M, Jaleel Z, Baertsch HC, et al. Inter-rater and Intra-rater Reliability of Glottal Image Capture: A Mobile Application to Quantify Vocal Fold Bowing. Laryngoscope. 2024. PMID: 39651659. doi:10.1002/lary.31942

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。