使用无线自动听力测试系统在儿童和青少年中与手动听力计比较进行扩展高频听力测试
横断面研究纳入28名典型发育儿童和青少年,比较声场内手动听力计与无线自动听力测试系统(WAHTS)Békésy样自动听力计(ABA)的阈值,以及声场内外ABA的阈值。结果显示ABA在常规频率阈值约好5 dB、扩展高频约好14 dB,声场外ABA与声场内ABA多数在±10 dB内一致。
要点
- 在儿童和青少年中,WAHTS ABA在常规频率的阈值比手动听力计约好5 dB。
- 在扩展高频(10-16 kHz),WAHTS ABA阈值比手动听力计约好14 dB。
- 声场外ABA与声场内ABA阈值多数在±10 dB内一致(常规频率86%;扩展高频80%)。
核心结论
- WAHTS ABA在儿童和青少年中常规频率阈值优于手动听力计,与既往成人研究一致。
- 扩展高频WAHTS ABA阈值优于手动听力计,可能由于不同换能器相关校准值未按年龄调整。
- 需要进一步研究纳入健康儿童参与者的WAHTS自动Békésy样扩展高频阈值,以建立适合年龄的常模阈值用于噪声性听力损失和/或耳毒性监测项目。
研究设计与样本
- 横断面研究,纳入28名典型发育儿童和青少年(平均14.5岁;范围10至18岁)。
- 在声场内使用Interacoustics Equinox手动听力计和改良Hughson-Westlake 5 dB阈值技术测量0.25至16 kHz听力阈值。
- 在声场内和声场外以平衡顺序使用WAHTS和Békésy样2 dB阈值技术测量自动听力阈值。
主要发现
- 声场内ABA阈值在常规频率(0.25至8 kHz)总体比手动阈值约好5 dB。
- 在扩展高频(10至16 kHz),声场内ABA阈值总体比手动阈值约好14 dB。
- 声场外ABA阈值多数在声场内ABA阈值±10 dB内(常规频率86%;扩展高频80%)。
- 声场内ABA阈值在常规频率仅69%在手动阈值±10 dB内,在扩展高频仅32%在手动阈值±10 dB内。
临床怎么用
- 原文未据此给出推荐。
局限性
- 需要进一步研究纳入健康儿童参与者的WAHTS自动Békésy样扩展高频阈值,以建立适合年龄的常模阈值用于临床监测项目。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Valid wireless automated Békésy-like audiometry (ABA) outside a sound booth that includes extended high frequencies (EHF) would increase access to monitoring programs for individuals at risk for hearing loss, particularly those at risk for ototoxicity. The purpose of the study was to compare thresholds obtained with (1) manual audiometry using an Interacoustics Equinox and modified Hughson-Westlake 5 dB threshold technique to automated audiometry using the Wireless Automated Hearing Test System (WAHTS) and a Békésy-like 2 dB threshold technique inside a sound booth, and (2) ABA measured in the sound booth to ABA measured outside the sound booth. DESIGN: Cross-sectional study including 28 typically developing children and adolescents (mean = 14.5 years; range = 10 to 18 years). Audiometric thresholds were measured from 0.25 to 16 kHz with manual audiometry inside the sound booth and with ABA measured both inside and outside the sound booth in counterbalanced order. RESULTS: ABA thresholds measured inside the sound booth were overall about 5 dB better compared with manual thresholds in the conventional frequencies (0.25 to 8 kHz). In the EHFs (10 to 16 kHz), a larger threshold difference was observed, where ABA thresholds were overall about 14 dB better compared with manual thresholds. The majority of ABA thresholds measured outside the sound booth were within ±10 dB of ABA thresholds measured inside the sound booth (conventional: 86%; EHF: 80%). However, only 69% of ABA thresholds measured inside the sound booth were within ±10 dB of manual thresholds in the conventional frequencies and only 32% of ABA thresholds measured inside the sound booth were within ±10 dB of manual thresholds in the EHFs. CONCLUSIONS: These results indicate that WAHTS ABA results in better thresholds in conventional frequencies than manual audiometry in children and adolescents, consistent with previous studies in adults. Hearing thresholds for the EHF were better when measured with WAHTS ABA compared with manual audiometry, likely due to different transducer-related calibration values that are not age-adjusted. Additional studies of WAHTS automated Békésy-like EHF thresholds that include healthy pediatric participants are needed to establish age-appropriate normative thresholds for clinical application in monitoring programs for noise-induced hearing loss and/or ototoxicity.
引用
- Blankenship CM, Hickson LM, Quigley T, et al. Extended High-Frequency Audiometry Using the Wireless Automated Hearing Test System Compared to Manual Audiometry in Children and Adolescents. Ear Hear. 2024. PMID: 39722183. doi:10.1097/AUD.0000000000001621
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。