文献速递耳科与耳神经

高频听力损失中LS CE-Chirp与Click刺激听性脑干反应比较

Comparison of LS CE-Chirp and Click Stimuli in Auditory Brainstem Responses in High-Frequency Hearing Loss.
PubMed 文献 · Ear Hear · 2024-11-25

本研究比较LS CE-Chirp与Click刺激在高频听力损失患者(n=30)和正常听力者(n=30)中诱发的听性脑干反应。结果显示,正常对照组中80 dB nHL下LS CE-Chirp潜伏期长于Click;高频听力损失组中两种刺激无显著差异;LS CE-Chirp较少受听力损失程度影响,但其诊断价值尚需进一步研究。

要点

  • 正常听力者80 dB nHL下LS CE-Chirp波潜伏期较Click延长。
  • 高频听力损失组中LS CE-Chirp与Click刺激无显著差异。
  • LS CE-Chirp潜伏期较少受高频听力损失程度影响。

核心结论

  • 高频听力损失组中LS CE-Chirp刺激所得波潜伏期较少受听力损失程度影响。
  • 该差异是否具有诊断价值尚需在不同病理和听力损失构型的患者中进一步研究。

研究设计与样本

  • 研究纳入高频听力损失患者30例和正常听力者30例。
  • 高频听力损失者选自狩猎经验至少5年者。
  • 正常听力者所有频率纯音听阈须≤20 dB HL,测试频率为250至8000 Hz。
  • 所有受试者在80和60 dB nHL下接受ABR测试,刺激率为11.1次/秒。
  • 比较组内和组间ABR波I、III、V峰潜伏期及I至V峰间潜伏期。

主要发现

  • 正常对照组中,80 dB nHL强度、11.1次/秒刺激频率下LS CE-Chirp潜伏期值较Click刺激更长。
  • 高频听力损失组中,80 dB nHL强度下LS CE-Chirp与Click刺激间未检出显著差异(p > 0.005)。
  • 按4000 Hz阈值对高频听力损失患者分类后,Click刺激与行为4000 Hz阈值更相符。

局限性

  • 原文指出,LS CE-Chirp与Click的差异若要具有诊断价值,尚需在不同病理和听力损失构型的患者中进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The auditory brainstem response (ABR) is an evoked potential used to estimate the hearing thresholds and identify potential auditory pathologies. Although a click stimulus is generally used as an auditory stimulus in diagnostics, recent reports show that the Level-Specific CE-Chirp (LS CE-Chirp) stimulus can also be used for clinical diagnosis. In this study, we compared the auditory brainstem test outcomes of the LS CE-Chirp stimulus and the click stimulus in individuals with high-frequency hearing loss (HFHL). DESIGN: Patients with HFHL (n = 30) and individuals with normal hearing (n = 30) were included in the study. Audiometric pure-tone thresholds were determined for all subjects at 250 to 8000 Hz. For individuals with normal hearing, the pure-tone thresholds were required to be ≤20 dB HL for all frequencies. HFHL cases were selected from people with at least 5 years of hunting experience. All subjects were tested with ABR at 80 and 60 dB nHL. The ABR test was performed using click and LS CE-Chirp stimuli at a rate of 11.1/sec. ABR wave I, III, and V peak latencies and I to V interpeak latency values were compared within and among the groups. RESULTS: Longer latency values were obtained with the LS CE-Chirp stimulus at 80 dB nHL intensity and 11.1/sec stimulus frequency than with the click stimulus in the control group. No significant difference was detected between the LS CE-Chirp and click stimuli at the 80 dB nHL intensity level in the HFHL group ( p > 0.005). When the HFHL patients were classified according to the 4000 Hz threshold, the click stimulus was found to be more compatible with the behavioral 4000 Hz threshold. CONCLUSIONS: The wave latency values obtained with the LS CE-Chirp stimulus in the HFHL group, unlike with the click stimulation, were less affected by the level of hearing loss in the HFHL group. For this difference to have a diagnostic value, further studies would be needed on patients with different pathologies and hearing loss configurations.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Belet U, Akşit AM, Kösemihal E, et al. Comparison of LS CE-Chirp and Click Stimuli in Auditory Brainstem Responses in High-Frequency Hearing Loss. Ear Hear. 2024. PMID: 39582114. doi:10.1097/AUD.0000000000001586

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。