听力正常年轻工人中噪声暴露水平、噪声峭度与畸变产物耳声发射的关联
在中国浙江省制造业年轻工人中开展横断面研究,测量个体噪声暴露水平、累积噪声暴露(CNE)、峭度及峭度调整CNE(CNE-K),并检测畸变产物耳声发射(DPOAE)。多因素回归显示,调整年龄、性别和听力保护装置使用后,CNE-K在3、4、5 kHz频率对DPOAE水平有显著影响,4 kHz效应最大。
要点
- 噪声暴露水平和峭度均与DPOAE水平下降相关。
- 含CNE-K的模型R²较含CNE的模型增高。
- 调整年龄、性别和听力保护装置使用后,CNE-K在3、4、5 kHz对DPOAE水平有显著影响,4 kHz效应最大。
核心结论
- DPOAE是可检测常规听力计无法发现的局限区域耳蜗损伤的敏感检查。
- 本研究提示CNE-K是评估复杂噪声相关DPOAE水平的有效指标。
研究设计与样本
- 在中国浙江省制造业年轻工人中开展的横断面研究。
- 对参与者进行个体噪声暴露测量,获得A计权8小时归一化噪声暴露水平(LAeq,8hr)、累积噪声暴露(CNE)、峭度和峭度调整CNE(CNE-K)。
- 对参与者进行DPOAE检测并获得DPOAE水平。
- 采用单因素分析探讨噪声暴露水平、峭度与DPOAE水平的关系,并采用多因素回归模型评估调整年龄、性别和听力保护装置使用后的联合效应。
主要发现
- 各频带总体DPOAE曲线随频率增加呈波动下降趋势。
- 噪声暴露水平和峭度均与DPOAE水平下降相关。
- 含CNE-K作为复杂噪声联合指标的多元回归模型R²较含CNE的模型增高。
- 调整年龄、性别和听力保护装置使用后,CNE-K在3、4、5 kHz频率对DPOAE水平有显著影响,4 kHz效应最大。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Growing evidence has suggested that, in addition to noise exposure level, noise temporal structure (i.e., kurtosis) plays an important role in the development of noise-induced hearing loss, while most of the relevant research has been on the results of pure-tone audiometry. This study focuses on the combined effect of noise exposure level and noise kurtosis on distortion product otoacoustic emissions (DPOAEs) in young workers with normal hearing. DESIGN: A cross-sectional study among young workers in manufacturing industries was conducted in Zhejiang Province, China. Individual noise exposure measurements were performed on participants to obtain an A-weighted noise exposure level normalized to 8 hr ( LAeq, 8hr ), cumulative noise exposure (CNE), kurtosis, and kurtosis-adjusted CNE (CNE-K). The DPOAE test was performed on the participants and DPOAE levels were obtained. The relationships between noise exposure level, kurtosis, and DPOAE levels were explored by univariate analyses. Furthermore, multivariate regression models were conducted to estimate the combined effects of exposure level and kurtosis after adjusting for age, gender, and use of hearing protection devices. RESULTS: The overall DPOAE curves across frequency bands presented a fluctuating downward trend with increasing frequency. Both exposure level and kurtosis were found to be associated with decreases in DPOAE levels. The multivariate regression model including CNE-K as a joint indicator of complex noise showed an increased R2 compared with the model including CNE. After adjustment for age, gender, and the use of hearing protection devices, significant effects of CNE-K on DPOAE levels were observed at 3, 4, and 5 kHz frequencies, with maximum effect presented at 4 kHz. CONCLUSIONS: DPOAE is a sensitive test that can detect cochlear damage in limited areas that cannot be detected by conventional audiometry. The present study provided a more comprehensive understanding of the impact of complex noise on the DPOAE levels. It also suggested that CNE-K was an effective metric in assessing DPOAE levels associated with complex noise.
引用
- Wei F, Zhao W, Gao X, et al. Associations Between Noise Exposure Level, Noise Kurtosis, and Distortion Product Otoacoustic Emissions in Young Workers With Normal Hearing. Ear Hear. 2024. PMID: 39402715. doi:10.1097/AUD.0000000000001600
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。