文献速递耳科与耳神经

人工耳蜗电极阵列设计对术后言语感知的影响

Impact of Cochlear Implant Electrode Array Design on Post-Op Speech Perception.
PubMed 文献 · Otolaryngol Head Neck Surg · 2024-10-06

回顾性病历回顾纳入129例接受9种电极阵列中1种的人工耳蜗植入患者,按设计分为侧壁电极36例、中阶电极16例和蜗轴周电极77例。蜗轴周电极在术后6个月和24个月的辅音-元音-辅音(CNC)评分显著高于侧壁电极,在12个月时优于中阶电极;电极长度与CNC评分在6、12和24个月呈负相关。作者认为蜗轴周电极可能具有优化听力结果的潜在优势。

要点

  • 蜗轴周电极在6个月和24个月的CNC评分显著高于侧壁电极。
  • 蜗轴周电极在12个月时CNC评分优于中阶电极。
  • 电极长度与6、12和24个月的CNC评分呈负相关。

核心结论

  • 蜗轴周电极阵列(往往较短)在某些时间点相比较长的侧壁和中阶阵列表现出更好的言语感知结果,作者认为这些发现提示蜗轴周电极可能具有优化听力结果的潜在优势。

研究设计与样本

  • 回顾性病历回顾,共纳入129例患者,接受9种电极阵列中的1种。
  • 侧壁电极组36例,包括CI522、CI622、Flex24和Flex28。
  • 中阶电极组16例,包括HiRes Ultra 3D。
  • 蜗轴周电极组77例,包括CI512、CI532、CI612和CI632。

主要发现

  • 蜗轴周电极在术后6个月和24个月的CNC评分显著高于侧壁电极。
  • 蜗轴周电极在术后12个月的CNC评分优于中阶电极。
  • 电极长度与CNC评分在术后6、12和24个月呈负相关。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Electrode array design may impact hearing outcomes in patients who receive cochlear implants. The goal of this work was to assess differences in post operative speech perception among patients who received cochlear implants of differing designs and lengths. STUDY DESIGN: Retrospective chart review. SETTING: Tertiary Care Hospital. METHODS: Patients (n = 129) received 1 of 9 electrode arrays, which were categorized by design: Lateral wall electrodes (n = 36) included CI522, CI622 (Cochlear Americas), Flex24, and Flex28 (Med El). Midscala electrodes (n = 16) included HiRes Ultra 3D (Advanced Bionics). Perimodiolar electrodes (n = 77) included CI512, CI532, CI612, and CI632 (Cochlear Americas). Speech perception was evaluated using consonant-nucleus-consonant (CNC) tests and at 3, 6, 12, and 24 months postimplantation. RESULTS: Perimodiolar electrodes showed significantly higher CNC scores compared to lateral wall electrodes at 6 and 24 months. Perimodiolar electrodes also outperformed midscala electrodes at 12 months. An inverse relationship was observed between electrode length and CNC scores noted at 6, 12, and 24 months. CONCLUSION: Perimodiolar electrode arrays, which tend to be shorter, demonstrated better speech perception outcomes compared to the longer lateral wall and midscala arrays at some timepoints. These findings suggest a potential advantages of perimodiolar electrodes for optimizing hearing outcomes.

来源:Otolaryngol Head Neck Surg,查看原文。版权归原作者所有。

引用

  1. Pennington-FitzGerald W, Waring NA, Hamiter M, et al. Impact of Cochlear Implant Electrode Array Design on Post-Op Speech Perception. Otolaryngol Head Neck Surg. 2024. PMID: 39369438. doi:10.1002/ohn.995

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。