屈光不正对视频头脉冲试验结果的影响
研究纳入82例患者,按屈光状态分为近视、近视散光、散光及正视对照组,均行视频头脉冲试验。结果显示近视和近视散光患者左右侧向、前、后半规管增益值均显著高于对照组,且增益值与近视度数呈显著相关;作者认为年龄可能影响增益值,评估结果时应考虑该因素并在必要时校正。
要点
- 近视和近视散光患者视频头脉冲试验增益值高于正视对照组。
- 左右侧向、前、后半规管增益值与近视度数呈显著相关。
- 年龄可能影响增益值,评估视频头脉冲试验结果时应考虑并必要时校正。
核心结论
- 近视患者的视频头脉冲试验增益值高于无屈光不正患者,年龄可能对增益值有影响。
- 评估视频头脉冲试验结果时考虑屈光因素并在必要时校正很重要。
研究设计与样本
- 研究纳入82例患者,所有患者均接受视频头脉冲试验。
- 按屈光不正分为近视、近视散光、散光及正视对照组四组。
主要发现
- 近视患者比散光患者和对照组年轻,近视散光患者比散光患者年轻。
- 对照组左右侧向、前、后半规管增益值均显著低于近视和近视散光患者(p < 0.05)。
- 左右侧向、前、后半规管增益值与近视度数之间存在显著关系(p < 0.05)。
临床怎么用
- 作者认为评估视频头脉冲试验结果时应考虑屈光不正和年龄因素,必要时进行校正。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The objective of this study is to investigate the potential influence of refractive error on Video Head Impulse Test outcomes. MATERIAL AND METHODS: Eighty-two patients were included in the study, and all patients underwent video head impulse testing. Patients were divided into four groups according to their refractive error: myopia, myopia-astigmatism, astigmatism, and emmetropia as control. RESULTS: Patients with myopia are younger than patients with astigmatism and controls; similarly, patients with myopia-astigmatism are younger than patients with astigmatism. The right and left lateral, anterior, and posterior gain values were statistically significantly lower in the control group compared with myopia and myopia-astigmatism patients (p < 0.05). There was a statistically significant relationship between the right and left lateral, anterior, and posterior gain values and the degree of myopia in the patients (p < 0.05). CONCLUSION: The results of the Video Head Impulse Test gain in myopia patients are higher than that in patients without refractive error. In addition, age may have an effect on gain values. It is important to consider this factor when evaluating the results of the Video Head Impulse Test in patients, and corrections should be made if necessary. LEVEL OF EVIDENCE: 3 Laryngoscope, 135:345-351, 2025.
引用
- Dikici O, Aslanci ME, Ekim B, et al. Refractive Error Impact on Video Head Impulse Test Outcomes. Laryngoscope. 2024. PMID: 39158011. doi:10.1002/lary.31715