文献速递睡眠呼吸障碍咽喉与嗓音

阻塞性睡眠呼吸暂停手术评估中使用的患者报告结局测量工具:一项系统综述

Patient Reported Outcome Measures used in Surgical Evaluation of Obstructive Sleep Apnea: A Systematic Review.
PubMed 文献 · Laryngoscope · 2024-07-10

本系统综述检索PubMed、Web of Science、Embase、PsychINFO和CINAHL,纳入用于睡眠手术研究并在睡眠障碍患者中验证的疾病特异性睡眠相关生活质量量表,采用COSMIN标准评价其方法学质量。共初筛2494篇摘要、216篇全文,最终识别7个患者报告结局测量工具(PROM);仅SAQLI(14%)同时基于患者与医生意见开发,无一个内容效度达到「充分」,6个(86%)内部一致性分析为「很好」。

要点

  • 共识别7个用于睡眠手术的睡眠相关生活质量PROM,仅SAQLI(14%)同时采纳患者与医生意见开发。
  • 按COSMIN标准无一个PROM的内容效度被评为「充分」。
  • 6个(86%)PROM内部一致性分析为「很好」,6个(86%)报告了重测信度数据。

核心结论

  • 用于OSA手术患者睡眠相关生活质量评估的PROM有多种,但其测量性能质量不一,且无一个PROM的内容效度达到充分质量。
  • 作者认为,新的和更新的OSA相关生活质量PROM应考虑纳入睡眠手术患者和提供者的意见。

研究设计与样本

  • 系统综述,按PRISMA指南实施,检索PubMed、Web of Science、Embase、PsychINFO和CINAHL。
  • 纳入标准为用于睡眠手术研究、并在睡眠障碍患者中验证的疾病特异性睡眠相关生活质量量表。
  • 采用COSMIN标准评价方法学质量;共检索到2494篇摘要,216篇进入全文审查。

主要发现

  • 共识别7个评估睡眠相关生活质量的PROM。
  • 仅1个(14%)PROM(SAQLI)在开发中同时采用患者与医生意见,无一个PROM的内容效度被评为「充分」。
  • 2个PROM在内容开发阶段使用了睡眠呼吸障碍患者,无一个PROM专门询问考虑手术的患者。
  • 6个(86%)PROM按COSMIN标准内部一致性分析为「很好」,6个(86%)包含重测信度数据。

关键数值与推荐

  • 内容效度:7个PROM中0个(0%)被评为「充分」,仅SAQLI(14%)同时采用患者与医生意见开发。
  • 内部一致性:6个(86%)PROM按COSMIN标准为「很好」。
  • 重测信度:6个(86%)PROM包含重测信度数据。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To identify patient-reported outcome measures (PROMs) used to measure adult obstructive sleep apnea (OSA)-related quality of life in sleep surgery and analyze key psychometric properties in the original design and development of each PROM. DATA SOURCES: PubMed, Web of Science, Embase, PsychINFO, and CINAHL. REVIEW METHODS: A systematic review was performed using Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. Disease-specific instruments assessing sleep-related quality of life that were used in sleep surgery studies and validated in patients with sleep disorders were included. The Consensus-based Standards for the Selection of Health Status Measurement Instruments (COSMIN) criteria were used to evaluate methodological quality. RESULTS: A total of 2494 abstracts were retrieved, and 216 underwent full-text review. Seven PROMs assessing sleep-related quality of life were identified. Only one (14%) PROM (SAQLI) was developed using both patient and physician input, and none were rated as "adequate" for content validity. Two PROMs utilized patients with sleep-disordered breathing during content development and none specifically queried patients considering surgery. Six (86%) PROMs demonstrated "very good" analysis of internal consistency per COSMIN criteria, and six (86%) included data on test-retest reliability. CONCLUSION: Several PROMs are utilized in sleep-related quality-of-life assessments for patients treated with OSA surgery. The measurement properties of these PROMs are of variable quality, and notably, no PROMs meet adequate quality measurements for content validity. New and updated PROMs for OSA-related quality of life should consider input from sleep surgery patients and providers. Laryngoscope, 134:4838-4846, 2024.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. Bhat A, Singh A, Durr ML, et al. Patient Reported Outcome Measures used in Surgical Evaluation of Obstructive Sleep Apnea: A Systematic Review. Laryngoscope. 2024. PMID: 38982930. doi:10.1002/lary.31603

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。