大鼠模型中精准靶向注射喉成形术及生物材料长期效果的高分辨率超声评估
本研究在大鼠单侧声带麻痹模型中建立超声引导下透明质酸注射喉成形术,利用超高频超声在注射前、注射后即刻、第2天、第7天及此后每周共4周进行纵向评估。结果显示注射侧声带宽度比显著增加并持续4周,而声门气道面积不变,超声、喉镜及组织学均证实注射成功。该方法可为声门功能不全治疗药物的筛选提供益处。
要点
- 建立大鼠超声引导下注射喉成形术新型手术模型
- 超声可精准定位注射并纵向记录填充与内移效果
- 注射后声带宽度比显著增加4周,声门气道面积不变
核心结论
- 在大鼠中建立了利用超声进行喉部注射的新型手术模型,除提供精准定位的视觉引导外,也展示了对治疗效果的可靠记录,该方法可为声门功能不全治疗药物的筛选提供益处。
研究设计与样本
- 在体动物研究,学术机构中进行,对诱导单侧声带麻痹一周后的Sprague-Dawley大鼠行超声引导下透明质酸注射喉成形术。
主要发现
- 超声、喉镜及组织学研究证实对麻痹声带的单侧注射均成功完成。
- 注射后4周内宽度比显著增加,而声门气道面积保持不变。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Current laryngeal injection models rely on the transoral route and are suboptimal due to limited view, narrowed working space, and the need to sacrifice animals for investigation of the injectables. In the present study, a novel surgical model for laryngeal intervention therapy utilizing an ultra-high frequency ultrasound imaging system was proposed. Based on this system, we developed a systemic evaluation approach, from guidance of the injection process, documentation of the injection site of the material, to in vivo longitudinal follow-up on the augmentation and medialization effect by analyzing the ultrasonography data. STUDY DESIGN: In vivo animal study. SETTING: Academic institution. METHODS: Injection laryngoplasty with hyaluronic acid under ultrasonography guidance was performed on Sprague-Dawley rats one week after induced unilateral vocal paralysis. Ultrasonography was performed at preinjection, immediately postinjection, on Day 2, Day 7 and then weekly for 4 weeks to obtain measurements, including the glottic area, angle between bilateral folds, and vocal fold width ratio. Laryngoscopic and histologic studies were also performed. RESULTS: Unilateral injections to the paralyzed fold were successfully performed as demonstrated by ultrasonographic, laryngoscopic, and histologic studies. The width ratio was significantly increased after injection for 4 weeks, while the glottic airway area was unchanged. CONCLUSION: Here, a novel surgical model for laryngeal injection utilizing ultrasonography in rats was established. In addition to providing visual guidance for precise localization of the injection, robust documentation of the treatment effect was also demonstrated. This methodology could be beneficial for screening therapeutic agents for treatment of glottic insufficiency.
引用
- Tseng WH, Hsiao TY, Yang TL, et al. Precision-Targeted Injection Laryngoplasty and Longitudinal Biomaterial Effects Evaluation Using High-resolution Ultrasonography in a Rat Model. Otolaryngol Head Neck Surg. 2024. PMID: 39033350. doi:10.1002/ohn.906
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。