使用Matrix测试时人工耳蜗植入者的瞳孔测量听力努力取决于声级而非信噪比
研究探讨人工耳蜗植入者在使用Matrix言语噪声测试时听力努力是否依赖任务难度,通过在广泛信噪比范围内测量峰值瞳孔扩张并与典型听力者比较。结果显示人工耳蜗植入组的峰值瞳孔扩张不显著依赖信噪比,而典型听力组依赖信噪比;主观努力评分两组均依赖信噪比。
要点
- 人工耳蜗植入者峰值瞳孔扩张不显著依赖信噪比,典型听力者则显著依赖。
- 两组主观努力评分均显著依赖信噪比。
- Matrix测试可能不适用于瞳孔测量法评估人工耳蜗植入者听力努力。
核心结论
- 信噪比变化对峰值瞳孔扩张无显著影响,提示Matrix测试可能不适用于瞳孔测量法评估人工耳蜗植入者听力努力。
- 主观评分测试在该人群中似乎更有前景,印证主观测量可能反映与瞳孔扩张不同的听力努力维度。
- 通过变化言语或噪声水平设定信噪比可对听力努力测量产生细微但显著的影响,且影响在典型听力者与人工耳蜗植入者间可能不同。
研究设计与样本
- 研究纳入一组多为老年的人工耳蜗植入者,在安静及多人babble噪声不同信噪比下进行荷兰/佛兰芒Matrix测试。
- 信噪比相对于言语识别阈设定,即0 dB、+5 dB和+10 dB re SRT;后2种条件通过固定噪声水平60 dBA变化言语水平或固定言语水平变化噪声水平获得。
- 将人工耳蜗植入组的峰值瞳孔扩张与一组典型听力者比较,并用Likert量表主观评分评估听力努力。
主要发现
- 人工耳蜗植入组峰值瞳孔扩张不显著依赖信噪比,而典型听力组信噪比显著影响峰值瞳孔扩张。
- 两组主观努力评分均显著依赖信噪比。
- 人工耳蜗植入者中,变化言语而固定噪声时峰值瞳孔扩张显著更大且努力评分更高。
- 典型听力者中,变化噪声而固定言语时努力评分显著更高且表现得分更低。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: We investigated whether listening effort is dependent on task difficulty for cochlear implant (CI) users when using the Matrix speech-in-noise test. To this end, we measured peak pupil dilation (PPD) at a wide range of signal to noise ratios (SNR) by systematically changing the noise level at a constant speech level, and vice versa. DESIGN: A group of mostly elderly CI users performed the Dutch/Flemish Matrix test in quiet and in multitalker babble at different SNRs. SNRs were set relative to the speech-recognition threshold (SRT), namely at SRT, and 5 and 10 dB above SRT (0 dB, +5 dB, and +10 dB re SRT). The latter 2 conditions were obtained by either varying speech level (at a fixed noise level of 60 dBA) or by varying noise level (with a fixed speech level). We compared these PPDs with those of a group of typical hearing (TH) listeners. In addition, listening effort was assessed with subjective ratings on a Likert scale. RESULTS: PPD for the CI group did not significantly depend on SNR, whereas SNR significantly affected PPDs for TH listeners. Subjective effort ratings depended significantly on SNR for both groups. For CI users, PPDs were significantly larger, and effort was rated higher when speech was varied, and noise was fixed for CI users. By contrast, for TH listeners effort ratings were significantly higher and performance scores lower when noise was varied, and speech was fixed. CONCLUSIONS: The lack of a significant effect of varying SNR on PPD suggests that the Matrix test may not be a feasible speech test for measuring listening effort with pupillometric measures for CI users. A rating test appeared more promising in this population, corroborating earlier reports that subjective measures may reflect different dimensions of listening effort than pupil dilation. Establishing the SNR by varying speech or noise level can have subtle, but significant effects on measures of listening effort, and these effects can differ between TH listeners and CI users.
引用
- Stronks HC, Tops AL, Quach KW, et al. Listening Effort Measured With Pupillometry in Cochlear Implant Users Depends on Sound Level, But Not on the Signal to Noise Ratio When Using the Matrix Test. Ear Hear. 2024. PMID: 38886888. doi:10.1097/AUD.0000000000001529
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。