文献速递耳科与耳神经小儿耳鼻咽喉

儿童耳鼻咽喉科手术室噪声暴露水平评估

Evaluation of Noise Exposure Levels in Pediatric ENT Operating Rooms.
PubMed 文献 · Otolaryngol Head Neck Surg · 2024-06-17

该横断面研究在单一三级医疗中心比较了常见儿童耳鼻咽喉科手术中手术器械在术者和患儿耳水平产生的噪声强度,并与环境噪声及Apple Watch噪声应用进行对比。共记录62例手术中的242次噪声,人工耳蜗植入术患儿耳水平最响(91.8 Lq峰值dB,P < .001),耳科钻为患儿最响器械(92.1 Lq峰值dB,P < .001),动力微型清创器为术者最响器械(90.7 Lq峰值dB,P = .036)。作者认为耳鼻咽喉科手术室噪声可超过正常安全阈值,应采取缓解策略。

要点

  • 儿童耳鼻咽喉科手术室噪声可超过正常安全阈值,可能使医务人员暴露于噪声相关听力损失。
  • 人工耳蜗植入术患儿耳水平噪声最响(91.8 Lq峰值dB,P < .001),耳科钻为患儿最响器械(92.1 Lq峰值dB,P < .001)。
  • 作者建议采取缓解策略,包括关注手术器械音量设置和定期用声音应用进行分贝测量。

核心结论

  • 耳鼻咽喉科手术室噪声可超过正常安全阈值,未意识到这一点可能使医务人员无意中暴露于噪声相关听力损失,应采取缓解策略。

研究设计与样本

  • 横断面研究,在单一三级医疗中心进行,使用RISEPRO声级计和SoundMeter X 10.0.4每5分钟在术者和患儿耳水平测量噪声,记录手术方式和器械类型,并与环境噪声水平及Apple Watch噪声应用比较。
  • 共记录62例手术中的242次噪声 occasions。

主要发现

  • 人工耳蜗植入术在患儿耳水平产生最响的噪声(91.8 Lq峰值dB;P < .001)。
  • 耳科钻是对患儿最响的器械(92.1 Lq峰值dB;P < .001),动力微型清创器是对术者最响的器械(90.7 Lq峰值dB;P = .036)。
  • 术者与患儿之间的噪声测量结果相似(P < .05)。
  • 噪声应用与声级计的整体一致性极好(组内相关系数0.8,95%CI 0.32-0.92)。

临床怎么用

  • 作者认为应采取缓解策略,包括关注手术器械音量设置和定期用声音应用进行分贝测量,以促进长期听力保护。
  • 原文讨论指出,噪声的持续时间、暴露频率和音量水平应进一步研究。

局限性

  • 原文讨论指出,噪声的持续时间、暴露频率和音量水平应进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Operating room (OR) sounds may surpass noise exposure thresholds and induce hearing loss. Noise intensity emitted by various surgical instruments during common pediatric otolaryngologic procedures were compared at the ear-level of the surgeon and patient to evaluate the need for quality improvement measures. STUDY DESIGN: Cross-sectional study. SETTING: Single tertiary care center. METHODS: Noise levels were measured using the RISEPRO Sound Level Meter and SoundMeter X 10.0.4 at the ear level of surgeon and patient every 5 minutes. Operative procedure and instrument type were recorded. Measured noise levels were compared against ambient noise levels and the Apple Watch Noise application. RESULTS: Two hundred forty-two total occasions of noise were recorded across 62 surgical cases. Cochlear implantation surgery produces the loudest case at the ear-level of the patient (91.8 Lq Peak dB; P < .001). The otologic drill was the loudest instrument for the patient (92.1 Lq Peak dB; P < .001), while the powered microdebrider was the loudest instrument for the surgeon (90.7 Lq Peak dB; P = .036). Noise measurements between surgeon and patient were similar (P < .05). Overall agreement between the Noise application and Sound Level Meter was excellent (intraclass correlation coefficient of 0.8, with a 95% confidence interval ranging from 0.32 to 0.92). CONCLUSION: Otolaryngology OR noises can surpass normal safe thresholds. Failure to be aware of this may unwittingly expose providers to noise-related hearing loss. Mitigation strategies should be employed. Quality improvement measures, including attention to surgical instrument volume settings and periodic decibel measurements with sound applications, can promote long-term hearing conservation. DISCUSSION: Otolaryngology OR noises can surpass normal safe thresholds. Failure to be aware of this may unwittingly expose providers to noise-related hearing loss. The duration, frequency of exposure, and volume levels of noise should be studied further. IMPLICATIONS FOR PRACTICE: Mitigation strategies should be employed. Quality improvement measures, including attention to surgical instrument volume settings and periodic decibel measurements with sound applications, can promote long-term hearing conservation.

来源:Otolaryngol Head Neck Surg,查看原文。版权归原作者所有。

引用

  1. Shakhtour L, Song S, Orobello NC, et al. Evaluation of Noise Exposure Levels in Pediatric ENT Operating Rooms. Otolaryngol Head Neck Surg. 2024. PMID: 38881393. doi:10.1002/ohn.857

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。