共聚焦激光显微内镜在鼻内镜鼻窦手术中行光学活检的可行性:一项先导研究

Feasibility of Optical Biopsy During Endoscopic Sinus Surgery With Confocal Laser Endomicroscopy: A Pilot Study.
PubMed 文献 · Laryngoscope · 2024-05-18

该先导研究在6例鼻腔/鼻窦病变患者中实施共聚焦激光显微内镜(CLE)检查,获取42个序列共3792张图像,并以组织病理学为参考,由3名对病理结果设盲的独立评估者判读。健康与炎性黏膜同恶性病变鉴别的准确率84.1%、敏感度85.4%、特异度83.1%、阳性预测值72.5%、阴性预测值92.1%,评估者间一致性Fleiss κ=0.62。作者认为该技术虽有局限,但有望作为鼻窦手术中的辅助影像手段,需在更大、更多样人群中建立评分系统以进一步研究。

要点

  • 6例患者获42个序列3792张图像,以组织病理学为标准参照。
  • 健康/炎性黏膜与恶性病变鉴别的准确率84.1%、敏感度85.4%。
  • 评估者间一致性Fleiss κ=0.62,作者提出需在更大样本人群中建立评分系统。

核心结论

  • 作者认为该技术尽管存在局限,仍有望作为鼻窦手术中的辅助影像技术;需在更大、更多样人群中建立基于可重复且明确特征的评分系统,以改善其诊断价值和临床实用性。

研究设计与样本

  • 单组病例系列先导研究,纳入6例鼻腔各种病变患者(3例慢性鼻窦炎、腺癌、脑膜脑膨出、嗅神经母细胞瘤)。
  • 对鼻腔和/或鼻窦不同结构采集42个序列共3792张图像,在相应部位取活检行苏木精-伊红染色作为标准参照。
  • 由3名对组织病理学设盲的独立评估者判读序列;证据等级NA。

主要发现

  • 健康与炎性黏膜同恶性病变鉴别的准确率84.1%、敏感度85.4%、特异度83.1%、阳性预测值72.5%、阴性预测值92.1%。
  • 评估者间一致性为Fleiss κ=0.62。
  • 鼻腔和鼻窦良恶性病变常频繁并存且种类繁多,可能给CLE光学活检带来更大挑战。

关键数值与推荐

  • 准确率84.1%,敏感度85.4%,特异度83.1%,阳性预测值72.5%,阴性预测值92.1%(均为健康/炎性黏膜与恶性病变的鉴别)。
  • 评估者间一致性Fleiss κ=0.62。

临床怎么用

  • 作者认为该技术有望作为鼻窦手术中的辅助影像技术,并建议进一步研究在更大、更多样人群中建立基于可重复且明确特征的评分系统。

局限性

  • 原文在结论中自述该技术存在局限但未具体列出;作者提出需在更大、更多样人群中建立评分系统以进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Confocal laser endomicroscopy (CLE) is an optical imaging technique that allows in vivo, real-time, microscope-like assessment of superficial lesions. Although there is substantial data on CLE use in the upper GI tract, there is limited information regarding its application in the nasal cavity and paranasal sinuses. This study aims to assess the feasibility and diagnostic metrics of CLE in the nasal cavity and paranasal sinuses regarding differentiation between healthy/benign and malignant tissue. These structures show, however, a wider variety of frequent and concomitant benign and malignant pathologies, which could pose an increased challenge for optical biopsy by CLE. METHODS: We performed CLE on a case series of six patients with various findings in the nose (three chronic rhinosinusitis, adenocarcinoma, meningoenzephalozele, esthesionneuroblastoma). Forty-two sequences (3792 images) from various structures in the nasal cavity and/or paranasal sinuses were acquired. Biopsies were taken at corresponding locations and analyzed in hematoxylin and eosin staining as a standard of reference. Three independent examiners blinded to the histopathology assessed the sequences. RESULTS: Healthy and inflamed mucosa could be distinguished from malignant lesions with an accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of 84.1%, 85.4%, 83.1%, 72.5%, and 92.1%, respectively, with a substantial agreement between raters (Fleiss κ = 0.62). CONCLUSION: This technique shows, despite its limitations, potential as an adjunctive imaging technique during sinus surgery; however, the creation of a scoring system based on reproducible and defined characteristics in a larger more diverse population should be the focus of further research to improve its diagnostic value and clinical utility. LEVEL OF EVIDENCE: NA Laryngoscope, 134:4217-4224, 2024.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. Frenken AK, Sievert M, Panuganti B, et al. Feasibility of Optical Biopsy During Endoscopic Sinus Surgery With Confocal Laser Endomicroscopy: A Pilot Study. Laryngoscope. 2024. PMID: 38761157. doi:10.1002/lary.31503

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。