文献速递耳科与耳神经小儿耳鼻咽喉

不同啁啾声刺激下的听觉电生理阈值及其与听力障碍儿童行为阈值的相关性

Auditory Electrophysiological Thresholds With Different Chirps and Their Correlation With Behavioral Thresholds in Hearing-Impaired Children.
PubMed 文献 · Ear Hear · 2024-05-30

该研究纳入20例6个月至12岁不同程度听力障碍儿童,比较窄带CE-Chirp Level Specific与窄带iChirp两种啁啾声刺激在500、1000、2000、4000 Hz获得听性脑干反应电生理阈值,并与行为阈值(纯音测听或视觉强化测听)做相关分析,同时比较检查时长。两种刺激所得阈值高度相关,1000、2000、4000 Hz电生理与行为阈值显著相关,平均差异小于6 dB nHL;检查时长分别为47.63(±19.41)分钟与52.42(±26)分钟,iChirp在极重度听力损失时检查时间显著更短。

要点

  • 两种窄带啁啾声刺激所得电生理阈值高度相关,1000、2000、4000 Hz与行为阈值显著相关。
  • 电生理与行为阈值平均差异小于6 dB nHL,检查时长分别为47.63(±19.41)分钟与52.42(±26)分钟。
  • 窄带iChirp在极重度听力损失时检查时间显著更短,窄带CE-Chirp Level Specific的检查时长与听力损失程度无关。

核心结论

  • 窄带CE-Chirp Level Specific与窄带iChirp对听力障碍儿童的电生理听觉阈值给出相似估计,能准确估计行为阈值,两者检查时长相当。
  • 窄带iChirp的检查时间受听力损失程度影响,极重度听力损失儿童检查更快。
  • 作者认为两种刺激在临床探索听力障碍儿童电生理阈值方面具有显著前景。

研究设计与样本

  • 研究纳入20例6个月至12岁、轻度至极重度听力障碍儿童,双侧测量500、1000、2000、4000 Hz听性脑干反应电生理阈值并记录确定阈值所需时间。
  • 行为阈值根据儿童年龄采用纯音测听或视觉强化测听获得。
  • 数据分析采用Pearson与Spearman相关系数;检查时间比较采用Student t检验与Kruskal-Wallis检验。

主要发现

  • 两种窄带啁啾声刺激所得阈值之间呈显著相关。
  • 电生理与行为阈值在1000、2000、4000 Hz呈显著相关,尤其与纯音测听比较时。
  • 电生理与行为阈值平均差异小于6 dB nHL。
  • 检查时长在两种设备间相对一致,窄带CE-Chirp Level Specific平均47.63(±19.41)分钟,窄带iChirp平均52.42(±26)分钟。
  • 使用窄带CE-Chirp Level Specific时检查时长与听力损失程度无关;窄带iChirp在极重度测量时显示显著更短时长,差异有统计学意义。

关键数值与推荐

  • 电生理阈值测量频率为500、1000、2000、4000 Hz。
  • 电生理与行为阈值平均差异小于6 dB nHL。
  • 窄带CE-Chirp Level Specific平均检查时长47.63(±19.41)分钟,窄带iChirp平均52.42(±26)分钟。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Research focusing on changes in the clinical practice of audiological diagnosis has become increasingly necessary, particularly in pediatric audiology. The pursuit of accurate and reliable examinations has intensified given the importance of early detection and intervention in cases of childhood hearing loss. Thus, this study aims to investigate the correlation between electrophysiological auditory thresholds, as obtained through frequency-specific auditory brainstem responses with two distinct chirp stimuli (narrow-band CE-Chirp Level Specific and narrow-band iChirp), in children with hearing impairments. In addition, this research set out to correlate these thresholds with behavioral responses while simultaneously comparing the examination durations relative to the type of stimuli and the degree of hearing loss. DESIGN: A cohort of 20 children (aged 6 months to 12 years) with varying degrees of hearing impairment (ranging from mild to profound) were recruited. The participants underwent bilateral measurement of their electrophysiological thresholds via auditory brainstem responses across different frequencies (500, 1000, 2000, and 4000 Hz), and the timeframe for determining these thresholds was carefully recorded. Subsequently, behavioral thresholds were ascertained using pure-tone audiometry or visual reinforcement audiometry based on the child's age. The data collected was subsequently analyzed using Pearson and Spearman correlation coefficients. To compare examination times, the Student t test and the Kruskal-Wallis test were used. RESULTS: There was a pronounced correlation between the thresholds obtained through both narrow-band chirp stimuli. Moreover, a substantial correlation was found between electrophysiological and behavioral thresholds at 1000, 2000, and 4000 Hz, especially when compared with pure-tone audiometry. The mean differences between the electrophysiological and behavioral thresholds were below 6 dB nHL, and the exam duration was relatively consistent across both devices, averaging 47.63 (±19.41) min for the narrow-band CE-Chirp Level Specific and 52.42 (±26) min for the narrow-band iChirp. Notably, variations in exam duration did not relate to varying degrees of hearing loss when using the narrow-band CE-Chirp Level Specific. Nevertheless, the narrow-band iChirp indicated significantly shorter durations in instances of profound degree measurements, demonstrating a statistically significant difference. CONCLUSIONS: The narrow-band CE-Chirp Level Specific and narrow-band iChirp stimuli provided similar estimates of electrophysiological auditory thresholds in children with hearing impairments, giving accurate estimations of behavioral thresholds. The time it took to complete the assessment is comparable between both stimuli. For the narrow-band iChirp, the degree of hearing loss was shown to impact the testing time, and children with profound hearing loss underwent faster exams. Ultimately, this study exhibits significant clinical implications as it reveals that the narrow-band CE-Chirp Level Specific and narrow-band iChirp stimuli could be remarkably promising for clinically exploring electrophysiological thresholds in children with hearing impairments.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Leusin Mattiazzi Â, Cóser PL, Endruweit Battisti ID, et al. Auditory Electrophysiological Thresholds With Different Chirps and Their Correlation With Behavioral Thresholds in Hearing-Impaired Children. Ear Hear. 2024. PMID: 38797884. doi:10.1097/AUD.0000000000001511

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。