文献速递耳科与耳神经

用宽频吸光度回归模型自动诊断中耳与内耳机械性病变

Toward Automating Diagnosis of Middle- and Inner-ear Mechanical Pathologies With a Wideband Absorbance Regression Model.
PubMed 文献 · Ear Hear · 2024-05-27

研究开发多元逻辑回归分类模型,以宽频鼓室压测量获得的吸光度及气骨导差为特征,区分上半规管裂(SCD)、镫骨固定(SF)与正常耳。吸光度联合气骨导差时,SCD与SF鉴别敏感度达96%和97%,三分类中SCD、SF、正常耳敏感度分别为82%、97%、98%。

要点

  • 吸光度联合气骨导差可提高机械性耳病诊断敏感度。
  • 鼓室压峰压处吸光度分类性能优于0 daPa处。
  • 该模型或可在初诊时辅助快速分诊。

核心结论

  • 宽频吸光度与气骨导差联合作为多元逻辑回归模型特征,可在初诊时对机械性耳病提供良好诊断估计。

研究设计与样本

  • 研究测量SCD、SF及正常耳的吸光度,分别在鼓室压峰压和0 daPa处,并比较常规法与surge法估计耳道面积。
  • 采用多元逻辑回归分类模型,特征包括仅吸光度、仅气骨导差及吸光度+气骨导差。
  • 吸光度经主成分变换降维,引入正则化参数lambda控制过拟合,气骨导差为多频率平均值。
  • 通过调整主成分数、lambda大小及气骨导差平均所包含频率优化模型性能。
  • 模型在70%数据上训练、30%数据上验证,随机拆分交叉验证重复1000次。

主要发现

  • SCD与SF鉴别:仅吸光度时敏感度SCD为77%、SF为82%;吸光度+气骨导差时敏感度SCD为96%、SF为97%。
  • SCD与正常鉴别:仅吸光度时SCD敏感度为40%;吸光度+气骨导差时SCD敏感度为89%。
  • 三分类模型:仅吸光度时正确分类SCD 31%、SF 20%、正常耳81%;吸光度+气骨导差时敏感度SCD为82%、SF为97%、正常耳为98%。
  • 总体上,鼓室压峰压处吸光度分类性能优于0 daPa处。

临床怎么用

  • 作者认为,该诊断自动化可加快检查流程并提高资源效率。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: During an initial diagnostic assessment of an ear with normal otoscopic exam, it can be difficult to determine the specific pathology if there is a mechanical lesion. The audiogram can inform of a conductive hearing loss but not the underlying cause. For example, audiograms can be similar between the inner-ear condition superior canal dehiscence (SCD) and the middle-ear lesion stapes fixation (SF), despite differences in pathologies and sites of lesion. To gain mechanical information, wideband tympanometry (WBT) can be easily performed noninvasively. Absorbance , the most common WBT metric, is related to the absorbed sound energy and can provide information about specific mechanical pathologies. However, absorbance measurements are challenging to analyze and interpret. This study develops a prototype classification method to automate diagnostic estimates. Three predictive models are considered: one to identify ears with SCD versus SF, another to identify SCD versus normal, and finally, a three-way classification model to differentiate among SCD, SF, and normal ears. DESIGN: Absorbance was measured in ears with SCD and SF as well as normal ears at both tympanometric peak pressure (TPP) and 0 daPa. Characteristic impedance was estimated by two methods: the conventional method (based on a constant ear-canal area) and the surge method, which estimates ear-canal area acoustically.Classification models using multivariate logistic regression predicted the probability of each condition. To quantify expected performance, the condition with the highest probability was selected as the likely diagnosis. Model features included: absorbance-only, air-bone gap (ABG)-only, and absorbance+ABG. Absorbance was transformed into principal components of absorbance to reduce the dimensionality of the data and avoid collinearity. To minimize overfitting, regularization, controlled by a parameter lambda, was introduced into the regression. Average ABG across multiple frequencies was a single feature.Model performance was optimized by adjusting the number of principal components, the magnitude of lambda, and the frequencies included in the ABG average. Finally, model performances using absorbance at TPP versus 0 daPa, and using the surge method versus constant ear-canal area were compared. To estimate model performance on a population unknown by the model, the regression model was repeatedly trained on 70% of the data and validated on the remaining 30%. Cross-validation with randomized training/validation splits was repeated 1000 times. RESULTS: The model differentiating between SCD and SF based on absorbance-only feature resulted in sensitivities of 77% for SCD and 82% for SF. Combining absorbance+ABG improved sensitivities to 96% and 97%. Differentiating between SCD and normal using absorbance-only provided SCD sensitivity of 40%, which improved to 89% by absorbance+ABG. A three-way model using absorbance-only correctly classified 31% of SCD, 20% of SF and 81% of normal ears. Absorbance+ABG improved sensitivities to 82% for SCD, 97% for SF and 98% for normal. In general, classification performance was better using absorbance at TPP than at 0 daPa. CONCLUSION: The combination of wideband absorbance and ABG as features for a multivariate logistic regression model can provide good diagnostic estimates for mechanical ear pathologies at initial assessment. Such diagnostic automation can enable faster workup and increase efficiency of resources.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Eberhard KE, Merchant GR, Nakajima HH, et al. Toward Automating Diagnosis of Middle- and Inner-ear Mechanical Pathologies With a Wideband Absorbance Regression Model. Ear Hear. 2024. PMID: 38797886. doi:10.1097/AUD.0000000000001516

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。