文献速递耳科与耳神经

比较鼓室内电极Click刺激SP/AP面积比与 Tone Burst刺激SP波幅诊断梅尼埃病

Click SP/AP Area Ratio Vesrus Tone Burst SP Amplitude to Diagnose Ménière's Disease Using Electrocochleography.
PubMed 文献 · Otolaryngol Head Neck Surg · 2024-02-28

回顾性比较研究纳入95例接受耳蜗电图检查的患者,比较经鼓膜电极Click刺激SP/AP面积比、经鼓膜外电极Click刺激SP/AP面积比及经鼓膜电极Tone Burst刺激SP波幅诊断梅尼埃病的敏感度和特异度。经鼓膜电极Click刺激SP/AP面积比敏感度88.5%、特异度70.0%,优于Tone Burst刺激SP波幅(敏感度60.0%、特异度55.6%,P=.016)。

要点

  • 经鼓膜电极Click刺激SP/AP面积比诊断MD敏感度88.5%、特异度70.0%。
  • 经鼓膜电极Tone Burst刺激SP波幅敏感度60.0%、特异度55.6%。
  • 前者检测MD优于后者(P=.016),经鼓膜外电极Click刺激SP/AP面积比与后者无差异(P=.573)。

核心结论

  • Click刺激SP/AP面积比检测MD的敏感度和特异度高于Tone Burst刺激SP波幅。
  • 使用SP/AP面积比(敏感度88.5%)时耳蜗电图对MD诊断极为有用,改变了SP/AP波幅比(敏感度51.7%)敏感度不佳的声誉。

研究设计与样本

  • 回顾性比较研究,在三级医疗中心纳入95例符合耳蜗电图检查纳入标准的患者。
  • 比较经鼓膜电极Click刺激SP/AP面积比、经鼓膜外电极Click刺激SP/AP面积比及经鼓膜电极Tone Burst刺激SP波幅诊断MD的敏感度和特异度。
  • 首次比较经鼓膜电极Tone Burst刺激SP波幅与经鼓膜电极Click刺激SP/AP面积比。

主要发现

  • 患者平均年龄54岁,女性为主。
  • 经鼓膜电极Click刺激SP/AP面积比敏感度88.5%、特异度70.0%。
  • 经鼓膜电极Tone Burst刺激SP波幅敏感度60.0%、特异度55.6%。
  • 经鼓膜电极Click刺激SP/AP面积比检测MD优于经鼓膜电极Tone Burst刺激SP波幅(P=.016)。
  • 经鼓膜外电极Click刺激SP/AP面积比与经鼓膜电极Tone Burst刺激SP波幅之间无差异(P=.573)。

临床怎么用

  • 原文结论认为使用SP/AP面积比(敏感度88.5%)时耳蜗电图对MD诊断极为有用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To evaluate the sensitivity and the specificity of summating potential (SP)/action potential (AP) area under the curve (AUC) ratio by a transtympanic electrode and a click stimulus (TT-CS), SP/AP AUC ratio by an extratympanic electrode and a click stimulus (ET-CS) and SP amplitude value by a transtympanic electrode and tone burst stimulus (TT-TBS) in regard of Ménière's disease (MD) diagnosis. This is the first study that compares SP amplitude value performed by a TT-TBS and the SP/AP AUC ratio performed by a TT-CS. STUDY DESIGN: Retrospective comparative study. SETTINGS: Ninety-five patients met the inclusion criteria for electrocochleography (ECochG) testing in a tertiary care center. METHODS: The sensitivity and specificity of our different ECochG protocols were calculated in regard of the diagnosis of MD. RESULTS: The patients' mean age was 54 years old (female predominance). The sensitivity and the specificity of SP/AP area ratio by a TT-CS were 88.5% and 70.0%, respectively. On the other hand, the sensitivity and specificity for the SP amplitude value by a TT-TBS were 60.0% and 55.6%, respectively. SP/AP area ratio by TT-CS was statistically better than SP amplitude value by TT-TBS to detect MD disease (P = .016). However, no difference was identified between SP/AP area ratio by ET-CS and SP amplitude value by a TT-TBS (P = .573). CONCLUSION: SP/AP area ratio by click stimulation has higher sensitivity and specificity to detect MD compared to SP amplitude value by tone burst stimulation. ECochG would be extremely useful in the diagnosis of MD if we use the SP/AP area ratio (sensitivity: 88.5%); therefore, it changes the bad reputation of ECochG sensitivity using SP/AP amplitude ratio (sensitivity: 51.7%) for the diagnosis of MD.

来源:Otolaryngol Head Neck Surg,查看原文。版权归原作者所有。

引用

  1. Bawazeer N, Gagnon C, Maheu M, et al. Click SP/AP Area Ratio Vesrus Tone Burst SP Amplitude to Diagnose Ménière's Disease Using Electrocochleography. Otolaryngol Head Neck Surg. 2024. PMID: 38415882. doi:10.1002/ohn.693

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。