文献速递耳科与耳神经小儿耳鼻咽喉

噪声下与安静下人工耳蜗植入资格标准:患者术后获益是否相似?

Cochlear Implant Qualification in Noise Versus Quiet: Do Patients Demonstrate Similar Postoperative Benefits?
PubMed 文献 · Otolaryngol Head Neck Surg · 2024-02-14

回顾性图表综述纳入2012至2022年成人人工耳蜗植入者,比较需噪声下测试才符合标准的患者(NQ组,n=67)与安静下符合标准者(QQ组,n=771)的术后表现。NQ组术前及术后平均言语识别得分更高,但两组在最佳助听双耳聆听条件下开放集测试改善比例、SSQ评分、CIQOL评分及设备使用均相当,支持用噪声下测试判定临界候选者的植入资格。

要点

  • 仅安静下测试不合格、需噪声下测试才符合标准的患者(NQ组,n=67)术后最佳助听言语感知获益与安静下符合标准者(QQ组,n=771)相似。
  • 仅人工耳蜗 listening 条件下,QQ组在CNC和AzBio安静测试中显著改善的比例更高(如AzBio安静:88% vs 51%,P<.001)。
  • 两组术后SSQ评分、CIQOL评分及设备使用情况相当。

核心结论

  • 需要噪声下测试才能符合人工耳蜗植入资格的患者,在最佳助听言语感知和患者报告结局方面表现出与安静下符合标准者相似的改善,支持使用噪声下测试判定临界候选者的人工耳蜗植入资格。

研究设计与样本

  • 回顾性图表综述,纳入2012年至2022年间植入的成人人工耳蜗 recipient。
  • QQ组为安静下符合标准者(n=771),NQ组为植入耳术前AzBio安静测试>60%、需多说话者babble噪声测试才符合标准者(n=67)。

主要发现

  • QQ组(n=771)与NQ组(n=67)年龄和听力损失时长相似。
  • NQ组术前和术后平均言语识别得分更高。
  • 仅人工耳蜗 listening 条件下,QQ组在CNC和AzBio安静测试中显著改善的比例更大(如仅人工耳蜗AzBio安静:88% QQ vs 51% NQ,P<.001)。
  • 仅人工耳蜗AzBio +5 dB信噪比测试及最佳助听双耳聆听条件下所有开放集测试的改善在两组间相似(如双耳AzBio安静:73% QQ vs 59% NQ,P=.345)。
  • 术后SSQ评分、CIQOL评分和设备使用在两组间也相当。

临床怎么用

  • 作者认为,对于临界人工耳蜗候选者,可使用噪声下测试判定植入资格。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To assess patient factors, audiometric performance, and patient-reported outcomes in cochlear implant (CI) patients who would not have qualified with in-quiet testing alone. STUDY DESIGN: Retrospective chart review. SETTING: Tertiary referral center. METHODS: Adult CI recipients implanted between 2012 and 2022 were identified. Patients with preoperative AzBio Quiet > 60% in the implanted ear, requiring multitalker babble to qualify, comprised the in-noise qualifying (NQ) group. NQ postoperative performance was compared with the in-quiet qualifying (QQ) group using CNC, AzBio Quiet, and AzBio +5 dB signal-to-noise ratio. Speech, Spatial and Qualities of Hearing Scale (SSQ), Cochlear Implant Quality of Life scale (CIQOL-10), and daily device usage were also compared between the groups. RESULTS: The QQ group (n = 771) and NQ group (n = 67) were similar in age and hearing loss duration. NQ had higher average preoperative and postoperative speech recognition scores. A larger proportion of QQ saw significant improvement in CNC and AzBio Quiet scores in the CI-only listening condition (eg, CI-only AzBio Quiet: 88% QQ vs 51% NQ, P < .001). Improvement in CI-only AzBio +5 dB and in all open set testing in the best-aided binaural listening condition was similar between groups (eg, Binaural AzBio Quiet 73% QQ vs 59% NQ, P = .345). Postoperative SSQ ratings, CIQOL scores, and device usage were also equivalent between both groups. CONCLUSION: Patients who require in-noise testing to meet CI candidacy demonstrate similar improvements in best-aided speech perception and patient-reported outcomes as in-QQ, supporting the use of in-noise testing to determine CI qualification for borderline CI candidates.

来源:Otolaryngol Head Neck Surg,查看原文。版权归原作者所有。

引用

  1. Schauwecker N, Patro A, Holder JT, et al. Cochlear Implant Qualification in Noise Versus Quiet: Do Patients Demonstrate Similar Postoperative Benefits? Otolaryngol Head Neck Surg. 2024. PMID: 38353294. doi:10.1002/ohn.677

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。