Bow and Lean 试验对垂直半规管良性阵发性位置性眩晕罕见变异型的诊断价值
研究纳入567例垂直半规管良性阵发性位置性眩晕(BPPV)患者,评估Bow and Lean试验(BLT)对不同变异型的诊断意义。BLT阳性155例,后半规管BPPV亚型间眼震方向差异有统计学意义。BLT诊断敏感性在低头位为0.93、仰头位为1,特异性分别为0.93和0.82;前半规管BPPV占1.4%,目前尚无特异特征将其与后半规管BPPV区分。
要点
- 567例垂直半规管BPPV中前半规管BPPV占1.4%。
- BLT低头位诊断敏感性0.93、特异性0.93;仰头位敏感性1、特异性0.82。
- 后半规管BPPV亚型间BLT诱发眼震方向差异有统计学意义。
核心结论
- BLT的应用已从水平半规管扩展至其他垂直半规管变异型,但研究结果因患者特征和试验执行差异而不同。
- 目前尚未发现前半规管BPPV区别于后半规管BPPV的特异特征,限制了BLT对该变异型的应用。
研究设计与样本
- 研究纳入567例垂直半规管BPPV患者,对前半规管或后半规管BPPV患者每周复查直至BPPV转阴,分析BLT期间的眼震特征。
主要发现
- 567例垂直半规管BPPV中,1.4%为前半规管BPPV。
- BLT阳性155例,其中低头位出现下跳性眼震而仰头位无眼震者占15.52%,低头位下跳性眼震而仰头位上跳性眼震者占6.17%,后者主要见于后半规管管石症。
- 后半规管BPPV各亚型间BLT诱发眼震方向差异有统计学意义。
- BLT各体位间眼震潜伏期和持续时间无显著差异。
- BPPV各亚型间眼震持续时间和潜伏期差异有统计学意义,尤其见于壶腹嵴顶结石症与其他变异型之间。
关键数值与推荐
- BLT诊断敏感性:低头位0.93,仰头位1。
- BLT诊断特异性:低头位0.93,仰头位0.82。
- 证据等级:3级(据牛津循证医学中心)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文指出研究结果因患者特征和试验执行差异而不同。
- 原文指出目前尚未发现前半规管BPPV区别于后半规管BPPV的特异特征,限制了BLT对该变异型的应用。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The objective of this study was to assess the clinical significance of the Bow and Lean Test (BLT) for the diagnosis of different variants of vertical canal Benign Paroxysmal Positional Vertigo (BPPV). BLT is commonly used for diagnoses of lateral semicircular canal (LSC) BPPV. However, vertical nystagmus in the BLT may indicate the presence of other variants such as PSC-BPPV. METHODS: 567 patients with vertical canal BPPV were recruited. Patients with anterior semicircular canal (ASC) or PSC-BPPV were weekly examined until the negativization of BPPV. Nystagmus characteristics during BLT were analyzed. RESULTS: Of 567 patients with vertical canal BPPV, 1.4% had ASC-BPPV. BLT was positive in 155 patients, showing patterns like down-beating nystagmus in bowing and no nystagmus in leaning (15.52% of patients), and down-beating in bowing and up-beating in leaning (6.17%), which was predominantly present in PSC-canalolithiasis. Statistically significant differences were observed in the direction of nystagmus provoked by BLT in PSC-BPPV subtypes. No significant differences were found in nystagmus latency or duration during BLT positions. Among BPPV subtypes, there was a significant difference in nystagmus duration and latency, especially between cupulolithiasis and other variants. BLT's sensitivity was 0.93 in bowing and 1 in a leaning position, while specificity was 0.93 and 0.82 respectively. CONCLUSION: Beyond the LSC, the BLT has expanded to other variants. However, study results differ likely due to variations in patient characteristics and test execution. Currently, no specific features for ASC have been found to differentiate it from PSC-BPPV limiting the test's use for this variant. LEVEL OF EVIDENCE: 3, according to Oxford Center for Evidence-Based Medicine Laryngoscope, 134:2405-2410, 2024.
引用
- Martin-Sanz E, Chaure-Cordero M, Riestra-Ayora J, et al. Bow and Lean Test for Rare Variants of Vertical Semicircular Canal BPPV. Laryngoscope. 2023. PMID: 38087849. doi:10.1002/lary.31218
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。