文献速递耳科与耳神经小儿耳鼻咽喉

儿童人工耳蜗植入术中前庭功能的保留

Vestibular Preservation in Pediatric Cochlear Implantation.
PubMed 文献 · Laryngoscope · 2023-08-16

这项回顾性病例复习比较了儿童人工耳蜗植入前后的前庭功能测试,纳入44名儿童共59只植入耳,中位年龄2.8岁。多数采用纤细无支撑环电极(86.4%)和圆窗入路(91.5%),术后旋转椅、颈性前庭诱发肌源性电位、眼性前庭诱发肌源性电位、视频头脉冲试验和计算机动态姿势描记的正常结果保留率分别为75%、75%、85.7%、100%和100%,62.5%的患者术后未出现任何新发前庭缺陷。作者认为本队列前庭功能保留率高于既往许多研究,现代低创伤电极和植入技术可能是重要因素。

要点

  • 儿童人工耳蜗植入术后前庭功能保留率较高,62.5%患者术后未出现新发前庭缺陷。
  • 旋转椅测试正常结果保留75%(21/28),颈性前庭诱发肌源性电位保留75%(30/40)。
  • 眼性前庭诱发肌源性电位保留85.7%(6/7),视频头脉冲和计算机动态姿势描记均保留100%。

核心结论

  • 本队列儿童人工耳蜗植入术后前庭功能保留率高于既往许多研究报道。
  • 现代低创伤电极和植入技术可能是前庭功能保留率较高的重要因素。
  • 导致新发严重双侧前庭丧失并产生长期功能影响的风险似乎较低。
  • 作者认为需进一步研究不同人工耳蜗电极设计和植入入路对术后前庭功能保留的影响。

研究设计与样本

  • 回顾性病例复习,比较儿童人工耳蜗植入前后的前庭功能测试。
  • 研究对象为在一家三级儿童医院4年期间接受人工耳蜗植入的儿童。
  • 纳入44名儿童共59只植入耳,初次测试中位年龄2.8岁(范围7个月至21岁),男女比例1:1。
  • 手术方式为单侧26例、双侧同期13例、双侧序贯5例。
  • 多数植入纤细无支撑环电极(86.4%),采用圆窗入路(91.5%)。

主要发现

  • 旋转椅测试术前正常结果术后保留75%(21/28例患者)。
  • 颈性前庭诱发肌源性电位测试术前正常结果术后保留75%(30/40只受测耳)。
  • 眼性前庭诱发肌源性电位测试术前正常结果术后保留85.7%(6/7只受测耳)。
  • 视频头脉冲测试术前正常结果术后保留100%(9/9只受测耳)。
  • 计算机动态姿势描记术前正常结果术后保留100%(5/5例受测患者);总体62.5%患者术后未出现任何新发前庭缺陷。

关键数值与推荐

  • 旋转椅测试正常结果保留75%(21/28例患者)。
  • 颈性前庭诱发肌源性电位测试正常结果保留75%(30/40只受测耳)。
  • 眼性前庭诱发肌源性电位测试正常结果保留85.7%(6/7只受测耳)。
  • 视频头脉冲测试正常结果保留100%(9/9只受测耳)。
  • 计算机动态姿势描记正常结果保留100%(5/5例受测患者)。

临床怎么用

  • 原文未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Evaluate the rate of preserved vestibular function in pediatric cochlear implant surgery. STUDY DESIGN: Retrospective case review. METHODS: Pre- and post-operative vestibular tests were compared in children who underwent cochlear implantation at a tertiary level pediatric hospital over a 4-year period. RESULTS: Data from 59 implanted ears in 44 children was included. Median age was 2.8 years at initial testing (range 7 months - 21 years) with 1:1 male/female ratio. Implant surgeries were 26 unilateral, 13 bilateral simultaneous, and 5 bilateral sequential. The majority were implanted with slim, non-styletted electrodes (86.4%) via a round window approach (91.5%). Normal pre-operative results were preserved post-operatively on rotary chair testing in 75% (21/28) of patients, cervical vestibular evoked myogenic potential testing in (75%) 30/40 of ears tested, ocular vestibular evoked myogenic potential testing in 85.7% (6/7) of ears tested, video head impulse testing in 100% (9/9) of ears tested, and computerized dynamic posturography in 100% (5/5) of patients tested. Overall, 62.5% of patients had no new deficits on any vestibular test performed post-operatively. CONCLUSIONS: Preservation rates of vestibular function following cochlear implant surgery were higher in this cohort than what has been reported in many earlier studies. Contemporary, less traumatic electrodes and insertion techniques may be a significant factor. The risk of causing a new, severe bilateral vestibular loss with long-term functional impacts appears to be low. Further study is warranted on the impacts of different cochlear implant electrode designs and insertion approaches on post-operative vestibular preservation. LEVEL OF EVIDENCE: 4, Case Series Laryngoscope, 134:1913-1918, 2024.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. Licameli GR, Wang A, Zhou G, et al. Vestibular Preservation in Pediatric Cochlear Implantation. Laryngoscope. 2023. PMID: 37584403. doi:10.1002/lary.30978

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。