3D打印经皮注射喉成形术模拟器的验证:一项随机对照试验
本研究通过单盲随机对照试验评估3D打印喉模拟器对耳鼻咽喉科住院医师经皮注射喉成形术(PIL)操作能力的迁移效度。20名PIL操作少于10例的住院医师按毕业后年资区组随机分为常规教材组和常规教材加模拟器训练组。高年资住院医师中,模拟器训练组在经甲状舌骨入路中对组织尊重度显著优于对照组(p<0.0005);低年资住院医师间无显著差异。
要点
- 高年资住院医师经模拟器训练后经甲状舌骨入路组织尊重度显著优于对照组(p<0.0005)。
- 低年资住院医师接受模拟器训练后各项表现与对照组无显著差异。
- 两组基线置信水平和PIL经验无显著差异。
核心结论
- 在此首个用于耳鼻咽喉科诊室清醒操作的模拟器迁移效度研究中,低成本高保真3D打印PIL模拟器改善了高年资耳鼻咽喉科住院医师的PIL操作表现,提示该模型可能是有价值的高级受训者练习PIL的教育辅助工具。
研究设计与样本
- 单盲随机对照试验,纳入PIL操作例数少于10例的耳鼻咽喉科住院医师,按毕业后年资进行区组随机分组。
- 共20名住院医师完成测试,在解剖学不同的喉模型上经甲状舌骨和环甲膜入路实施PIL。
- 由两名设盲的喉科医师使用客观结构化技术技能评估量表和PIL专用检查表对去标识化的内镜和外部操作录像进行评估。
主要发现
- 高年资住院医师中,接受模拟器训练组在经甲状舌骨入路中的组织尊重度显著优于对照组(p < 0.0005)。
- 低年资住院医师中,接受模拟器训练组与对照组的表现无显著差异。
- 基线特征显示两组置信水平或PIL经验无显著差异。
临床怎么用
- 作者认为该易获得的模型可能是有价值的教育辅助工具,供高级受训者练习PIL。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Simulation may be a valuable tool in training laryngology office procedures on unsedated patients. However, no studies have examined whether existing awake procedure simulators improve trainee performance in laryngology. Our objective was to evaluate the transfer validity of a previously published 3D-printed laryngeal simulator in improving percutaneous injection laryngoplasty (PIL) competency compared with conventional educational materials with a single-blinded randomized controlled trial. METHODS: Otolaryngology residents with fewer than 10 PIL procedures in their case logs were recruited. A pretraining survey was administered to participants to evaluate baseline procedure-specific knowledge and confidence. The participants underwent block randomization by postgraduate year to receive conventional educational materials either with or without additional training with a 3D-printed laryngeal simulator. Participants performed PIL on an anatomically distinct laryngeal model via trans-thyrohyoid and trans-cricothyroid approaches. Endoscopic and external performance recordings were de-identified and evaluated by two blinded laryngologists using an objective structured assessment of technical skill scale and PIL-specific checklist. RESULTS: Twenty residents completed testing. Baseline characteristics demonstrate no significant differences in confidence level or PIL experience between groups. Senior residents receiving simulator training had significantly better respect for tissue during the trans-thyrohyoid approach compared with control (p < 0.0005). There were no significant differences in performance for junior residents. CONCLUSIONS: In this first transfer validity study of a simulator for office awake procedure in laryngology, we found that a previously described low-cost, high-fidelity 3D-printed PIL simulator improved performance of PIL amongst senior otolaryngology residents, suggesting this accessible model may be a valuable educational adjunct for advanced trainees to practice PIL. LEVEL OF EVIDENCE: NA Laryngoscope, 134:318-323, 2024.
引用
- Kostas JC, Lee AS, Arunkumar A, et al. Validation of a 3D-Printed Percutaneous Injection Laryngoplasty Simulator: A Randomized Controlled Trial. Laryngoscope. 2023. PMID: 37466294. doi:10.1002/lary.30878
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。