声带黏膜波与振动的组织学检查
在犬半喉活体模型中低与高肌肉激活条件下发声,用高速视频捕捉振动并三维重建标记点轨迹,再对同一半喉行组织学检查。结果显示犬与离体人模型的振荡模式高度相似,前两个本征函数占总运动方差超过90%,分别代表开闭与收敛发散运动;组织学见犬声带固有层上层较厚且甲杓肌纤维束排列与人研究描述相似。
要点
- 犬半喉活体与离体人模型振荡模式高度相似,前两个本征函数占总运动方差超过90%。
- 声门周期中存在垂直相位差,低与高肌肉激活条件下声带下缘与上缘的时间延迟在开相均大于闭相。
- 犬声带组织学见固有层上层较厚及甲杓肌纤维束独特排列,提示多层固有层可能并非人样发声振动模式所必需。
核心结论
- 犬声带的组织学与振动检查显示其人声带振动模式,尽管存在某些微结构差异。
- 本研究提示多层固有层可能并非人样发声所需振动模式的基本要素。
研究设计与样本
- 活体犬半喉在低与高肌肉激活条件下对玻璃棱镜发声。
- 用高速视频捕捉振动,对声带内侧面纹身标记点轨迹行三维重建。
- 采用经验本征函数法捕捉振动运动的基本动力学,并对半喉行组织学检查。
主要发现
- 活体犬与既往离体人模型的振荡模式高度相似。
- 两个最主要本征函数占总运动方差超过90%,分别代表开闭与收敛发散运动模式。
- 声门周期中存在垂直相位差,低与高肌肉激活条件下声带下缘与上缘的时间延迟在开相均大于闭相。
- 犬声带组织学显示固有层上层较厚,且甲杓肌纤维与肌束排列与人研究描述相似。
关键数值与推荐
- 两个最主要本征函数占总运动方差超过90%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Despite gross anatomic and histologic differences between human and canine vocal folds, similar wave patterns have been described yet not fully characterized. We reconstructed vocal fold (VF) vibration in a canine hemilarynx and performed histologic examination of the same vocal fold. We demonstrate comparable wave patterns while exploring the importance of certain anatomic architectures. METHODS: An in vivo canine hemilarynx was phonated against a glass prism at low and high muscle activation conditions. Vibration was captured using high-speed video, and trajectories of VF medial surface tattooed landmarks were 3D-reconstructed. The method of empirical eigenfunctions was used to capture the essential dynamics of vibratory movement. Histologic examination of the hemilarynx was performed. RESULTS: Oscillation patterns were highly similar between the in vivo canine and previous reports of ex vivo human models. The two most dominant eigenfunctions comprised over 90% of total variance of movement, representing opening/closing and convergent/divergent movement patterns, respectively. We demonstrate a vertical phase difference during the glottal cycle. The time delay between the inferior and superior VF was greater during opening than closing for both activation conditions. Histological examination of canine VF showed not only a thicker lamina propria layer superiorly but also a distinct pattern of thyroarytenoid muscle fibers and fascicles as described in human studies. CONCLUSIONS: Histologic and vibratory examination of the canine vocal fold demonstrated human vocal fold vibratory patterns despite certain microstructural differences. This study suggests that the multilayered lamina propria may not be fundamental to vibratory patterns necessary for human-like voice production. LEVEL OF EVIDENCE: NA (Basic science study) Laryngoscope, 134:264-271, 2024.
引用
- Chung HR, Reddy NK, Manzoor D, et al. Histologic Examination of Vocal Fold Mucosal Wave and Vibration. Laryngoscope. 2023. PMID: 37522475. doi:10.1002/lary.30928
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。