副神经的解剖变异性:对IIB区清扫的启示
该研究测量了150例接受颈清扫术患者的IIB区边界,其中184侧进行了测量,37.7%的II区淋巴结位于IIB区。副神经在II区内的平均长度为2.5厘米,每增加1厘米与IIB区淋巴结多2枚相关。副神经长度及其他因素与颈清扫损伤量表评分无相关性。
要点
- IIB区淋巴结占II区淋巴结的37.7%,副神经平均长度2.5厘米。
- 副神经长度每增加1厘米,IIB区淋巴结增加2枚。
- 副神经长度与术后颈部症状无相关性。
核心结论
- 副神经在IIB区内的长度越长,与IIB区淋巴结获取数量越多相关。
- 数据未提示存在可避免IIB区清扫的副神经长度截止值。
- IIB区的尺寸与术后颈部症状无相关性。
研究设计与样本
- 测量了150例接受颈清扫术患者的IIB区边界,共184侧。
- 术中分离IIA区和IIB区,使用颈清扫损伤量表评估50例患者的术后症状。
- 计算描述性统计量,分析IIB区尺寸与淋巴结数量、比例及转移淋巴结数量的相关性,并将IIB区尺寸作为术后症状的预测因素进行分析。
主要发现
- 184侧中,37.7%的II区淋巴结位于IIB区。
- 副神经在II区内的平均长度为2.5厘米。
- 副神经长度每增加1厘米,与IIB区淋巴结多2枚相关。
- 在所有副神经长度下,IIB区均存在有意义的淋巴结数量。
- 副神经长度及其他因素与颈清扫损伤量表评分无相关性。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: During neck dissection, level IIB lymphadenectomy necessitates manipulation of the spinal accessory nerve that might be avoided and might cause postoperative disability. Current literature does not describe the effect of variation in the spinal accessory nerve in the upper neck. We sought to measure the effect of the dimensions of level IIB on nodal yield in level IIB and on patient reported neck symptoms. METHODS: We measured the boundaries of level IIB of 150 patients undergoing neck dissection. Level II was dissected and separated into levels IIA and IIB intraoperatively. Patient-reported symptoms were assessed in 50 patients using the Neck Dissection Impairment Inventory. We computed descriptive statistics, and sought to identify correlation with the number and proportion of level IIB nodes and the number of metastatic nodes. Level IIB dimensions were analyzed as predictors of postoperative symptoms. RESULTS: We measured 184 sides, with 37.7% of level II nodes found in level IIB. Mean accessory nerve length across level II was 2.5 cm. Every additional 1 cm in accessory nerve length was associated with two more level IIB nodes. At all accessory nerve lengths, meaningful numbers of nodes were present in level IIB. Accessory nerve length and other factors did not correlate with NDII scores. CONCLUSIONS: Longer lengths of accessory nerve across level IIB correlated with greater nodal yield. However, data did not point to an accessory nerve length cutoff below which level IIB dissection could be avoided. In addition, the dimensions of level IIB did not correlate with postoperative neck symptoms. LEVEL OF EVIDENCE: 2 Laryngoscope, 134:154-159, 2024.
引用
- Pagedar NA, Hoffman HT. Anatomic Variability of the Accessory Nerve: Implications for Dissection of Level IIB. Laryngoscope. 2023. PMID: 37289066. doi:10.1002/lary.30758
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。