超声在药物诱导睡眠内镜下量化舌骨运动的应用
本研究为前瞻性队列的横断面分析,对20例接受药物诱导睡眠内镜及持续气道正压滴定的患者行舌骨超声,量化梗阻性与非梗阻性呼吸时的舌骨位移。梗阻性呼吸时平均舌骨位移为5.81 mm(±3.48),给予持续气道正压后所有患者舌骨位移均减小(-3.94 mm,95%CI:-5.10,-2.78;p<0.0001),基线舌骨位移与较高AHI相关(β=0.18,95%CI:0.03,0.33;p=0.020)。
要点
- 药物诱导睡眠内镜下,梗阻性呼吸时舌骨位移较非梗阻性呼吸增大,且患者间变异明显。
- 舌骨超声测量舌骨位移的评定者间信度优良。
- 基线舌骨位移与较高AHI相关(β=0.18,95%CI:0.03,0.33;p=0.020)。
核心结论
- 药物诱导睡眠内镜期间,梗阻性呼吸时舌骨位移更大,且患者间存在显著变异。
- 这些超声测量具有优良的评定者内和评定者间信度。
- 需要更多更大规模的研究来了解舌骨活动性的影响因素。
研究设计与样本
- 前瞻性队列的横断面分析,患者接受药物诱导睡眠内镜联合持续气道正压滴定及舌骨聚焦超声。
- 共20例患者符合纳入标准。
- 队列平均为男性(75%)、老年(65.9±10岁)、超重(29.3±3.99 kg/m2)、中度至重度OSA(29.3±12.5事件/小时)。
- 通过基于回声追踪舌骨运动生成位移曲线来量化运动,图像分析方案由两名研究者独立执行并评估测量信度。
- 对多种临床数据与梗阻性呼吸时舌骨位移进行单变量和多变量回归。
主要发现
- 梗阻性呼吸时平均舌骨位移为5.81 mm(±3.48)。
- 所有患者给予持续气道正压后舌骨位移均减小(-3.94 mm,95%CI:-5.10,-2.78;p<0.0001)。
- 舌骨位移测量的评定者间信度优良。
- 多变量回归后,基线舌骨位移与较高AHI相关(β=0.18,95%CI:0.03,0.33;p=0.020)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 需要更多更大规模的研究来了解舌骨活动性的影响因素。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The significance of hyoid dynamics in OSA pathophysiology remains unclear. Drug-induced sleep endoscopy (DISE) is often used for evaluating patients intolerant to positive airway pressure (PAP) therapy. We performed DISE with concurrent hyoid-focused ultrasonography to quantify hyoid dynamics during obstructive and non-obstructive breathing. METHODS: A cross-sectional analysis from a prospective cohort of patients undergoing DISE with PAP titration (DISE-PAP) and hyoid-focused ultrasound was conducted. Hyoid ultrasound was performed during obstructive breathing, and non-obstructive breathing after PAP administration. Motion was quantified by generating displacement curves based on echo-tracking hyoid movement. The image analysis protocol for quantifying hyoid displacement was performed independently by two researchers, and reliability of measures was assessed. Univariate and multivariate regressions were performed for various clinical data and hyoid displacement during obstructive breathing. RESULTS: Twenty patients met inclusion criteria. On average, the cohort was male (75%), elderly (65.9 ± 10 years), overweight (29.3 ± 3.99 kg/m2 ), and with moderate-to-severe OSA (29.3 ± 12.5 events/h). Mean hyoid displacement during obstructive breathing was 5.81 mm (±3.48). In all patients, hyoid displacement decreased after PAP administration (-3.94 mm [95% CI: -5.10, -2.78]; p < 0.0001). Inter-rater reliability for measures of hyoid displacement was excellent. After multivariate regression, hyoid displacement at baseline was associated with higher AHI (β [95% CI] = 0.18 [0.03, 0.33], p = 0.020). CONCLUSION: During DISE, hyoid displacement is greater during obstructive breathing with significant variability amongst patients. Further, these ultrasonographic measurements had excellent intra- and inter-rater reliability. Additional, larger studies are needed to understand contributors to hyoid mobility. LEVEL OF EVIDENCE: 4 Laryngoscope, 133:3221-3227, 2023.
引用
- Parekh MH, Thuler E, Triantafillou V, et al. The Application of Ultrasound to Quantify Hyoid Motion During Drug-Induced Sleep Endoscopy. Laryngoscope. 2023. PMID: 37283467. doi:10.1002/lary.30805
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。