外骨骼扶手在内镜鼻窦与颅底手术中改善工效学的可行性
本研究开发并评估一种为术者提供工效学辅助的外骨骼系统,在硅胶鼻腔模型、新鲜冷冻尸体和真实手术中开展五项实验,25名志愿者参与。使用扶手时舒适度更高、疲劳和疼痛更少(3.3,SD 1.75 vs. 5.9,SD 1.49;p=0.02),参与者认为设备直观、舒适并改善内镜使用的准确性和稳定性。
要点
- 使用外骨骼扶手时志愿者感知舒适度更高、疲劳和疼痛更少(3.3,SD 1.75 vs. 5.9,SD 1.49;p=0.02)。
- 参与者认为该设备直观、舒适,并改善内镜使用的准确性和稳定性。
- 该工效学辅助系统在模拟手术中测试,可用性可接受,疼痛和疲劳减轻及效率的初步结果极好,值得进一步研究。
核心结论
- 一种为术者提供工效学辅助的新系统在模拟手术中测试,可用性可接受,疼痛和疲劳减轻及效率的初步结果极好,值得进一步研究该技术。
研究设计与样本
- 在硅胶鼻腔模型、新鲜冷冻尸体和真实手术等不同且日益逼真的场景中开展五项实验,记录并计时每名志愿者的任务,使用美国国家航空航天局任务负荷指数(NASA-TLX)量表评估术者执行任务时的工作负荷。
- 25名志愿者参与实验。
主要发现
- 使用扶手时志愿者感知舒适度更高、疲劳和疼痛更少(3.3,SD 1.75 vs. 5.9,SD 1.49;p=0.02)。
- 参与者认为该设备直观、舒适,并改善内镜使用的准确性和稳定性。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文结论指出值得进一步研究该技术。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The main objective of this study was to develop and evaluate the feasibility and effectiveness of a novel exoskeleton system designed to provide ergonomic assistance to surgeons while preserving or improving the quality of endoscopic sinus and skull base surgical procedures. METHODS: To evaluate the functionality and ergonomic characteristics of the device, five experiments were conducted in different and increasingly realistic scenarios: silicone model of the nasal cavity, freshly frozen cadavers and finally in a real surgery. Each volunteer's task was recorded and timed. The National Aeronautics and Space Administration Task Load Index (NASA-TLX) rating scale was used to estimate the surgeons' workload while performing the tasks. RESULTS: Twenty-five volunteers took part in the experiments. Volunteers perceived more comfort and less fatigue and pain when using the armrest than when not using the device (3.3, SD 1.75 vs. 5.9 SD 1.49; p = 0.02). Participants found the device intuitive, comfortable, and improving accuracy and stability with endoscope use. CONCLUSION: A new system that provides ergonomic assistance to surgeons was tested in simulation surgery with acceptable usability. Initial results in terms of pain and fatigue reduction and efficiency were excellent, justifying further research into this technology. LEVEL OF EVIDENCE: NA Laryngoscope, 134:79-86, 2024.
引用
- Lobo D, Sancibrian R, Mesones A, et al. Feasibility of an Exoskeleton Armrest to Improve Ergonomics during Endoscopic Sinus and Skull Base Surgery. Laryngoscope. 2023. PMID: 37255028. doi:10.1002/lary.30790