文献速递耳科与耳神经

成人范德堡疲劳量表简版VFS-A-10的编制与验证

Development and Validation of a Brief Version of the Vanderbilt Fatigue Scale for Adults: The VFS-A-10.
PubMed 文献 · Ear Hear · 2023-04-27

研究基于40条目成人范德堡疲劳量表(VFS-A-40),分两阶段(N=580、N=607)编制10条目简版VFS-A-10,并在独立样本中评估其结构、信度与效度。结果显示VFS-A-10为单维结构,重测信度优秀(rs=0.88),对听力相关疲劳敏感,适合临床使用。

要点

  • VFS-A-10由VFS-A-40经项目反应理论分析筛选10个高质量条目编制而成。
  • VFS-A-10为单维结构,重测信度优秀(rs=0.88),测量范围覆盖广泛疲劳严重度。
  • VFS-A-10对自报听力困难相关疲劳的敏感性优于通用疲劳量表。

核心结论

  • VFS-A-10是测量成人听力相关疲劳的可靠、有效且敏感的工具,其简短、高敏感性和良好信度适合临床使用。
  • 该量表有助于识别受听力相关疲劳影响最大者,并评估旨在减少其负面影响的干预措施的获益。

研究设计与样本

  • 研究分两阶段:阶段1(N=580)基于VFS-A-40的项目反应理论分析筛选高质量条目形成10条目简版VFS-A-10。
  • 阶段2(N=607)在独立样本中评估VFS-A-10的特征与质量,受试者为通过在线广告、病历回顾和既往研究参与者库招募的便利样本。
  • 阶段2中145名参与者在初次测量后约一个月(范围5至90天)完成第二次VFS-A-10以评估重测信度。

主要发现

  • 探索性因子分析提示VFS-A-10为单维结构,项目反应理论分析确认所有条目质量高。
  • 项目反应理论信度分析显示在广泛疲劳严重度范围内测量保真度良好;重测信度优秀(rs=0.88,合并所有参与者)。
  • 项目反应理论差异条目功能分析确认VFS-A-10在不同年龄、性别和听力状态受试者中均提供有效的听力相关疲劳测量。
  • VFS-A-10得分与通用疲劳/活力测量的相关性仅为弱至中等(Spearman相关系数rs=-0.36至0.57),与感知听力困难测量的相关性更强(rs=0.79至0.81)。
  • VFS-A-10对自报听力困难相关疲劳的敏感性优于通用测量,对随听力障碍程度变化的疲劳的敏感性也优于通用测量。

关键数值与推荐

  • 重测信度:rs=0.88(合并所有参与者,初次测量后约一个月复测,范围5至90天)。
  • 与通用疲劳/活力测量的相关性:Spearman相关系数rs=-0.36至0.57。
  • 与感知听力困难测量的相关性:rs=0.79至0.81。

临床怎么用

  • 作者认为VFS-A-10的简短、高敏感性和良好信度使其适合临床使用。
  • 作者认为该量表可用于识别受听力相关疲劳影响最大者,并评估旨在减少其负面影响的干预措施的获益。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Listening-related fatigue can be a significant problem for adults who struggle to hear and understand, particularly adults with hearing loss. However, valid, sensitive, and clinically useful measures for listening-related fatigue do not currently exist. The purpose of this study was to develop and validate a brief clinical tool for measuring listening-related fatigue in adults. DESIGN: The clinical scale was derived from the 40-item version of the Vanderbilt Fatigue Scale for Adults (VFS-A-40), an existing, reliable, and valid research tool for measuring listening-related fatigue. The study consisted of two phases. Phase 1 ( N = 580) and Phase 2 ( N = 607) participants consisted of convenience samples of adults recruited via online advertisements, clinical records review, and a pool of prior research participants. In Phase 1, results from item response theory (IRT) analyses of VFS-A-40 items were used to identify high-quality items for the brief (10-item) clinical scale: the VFS-A-10. In Phase 2, the characteristics and quality of the VFS-A-10 were evaluated in a separate sample of respondents. Dimensionality was evaluated using exploratory factor analyses (EFAs) and item quality and characteristics were evaluated using IRT. VFS-A-10 reliability and validity were assessed in multiple ways. IRT reliability analysis was used to examine VFS-A-10 measurement fidelity. In addition, test-retest reliability was assessed in a subset of Phase 2 participants ( n = 145) who completed the VFS-A-10 a second time approximately one month after their initial measure (range 5 to 90 days). IRT differential item functioning (DIF) was used to assess item bias across different age, gender, and hearing loss subgroups. Convergent construct validity was evaluated by comparing VFS-A-10 responses to two other generic fatigue scales and a measure of hearing disability. Known-groups validity was assessed by comparing VFS-A-10 scores between adults with and without self-reported hearing loss. RESULTS: EFA suggested a unidimensional structure for the VFS-A-10. IRT analyses confirmed all test items were high quality. IRT reliability analysis revealed good measurement fidelity over a wide range of fatigue severities. Test-retest reliability was excellent ( rs = 0.88, collapsed across participants). IRT DIF analyses confirmed the VFS-A-10 provided a valid measure of listening-related fatigue regardless of respondent age, gender, or hearing status. An examination of associations between VFS-A-10 scores and generic fatigue/vigor measures revealed only weak-to-moderate correlations (Spearman's correlation coefficient, rs = -0.36 to 0.57). Stronger associations were seen between VFS-A-10 scores and a measure of perceived hearing difficulties ( rs = 0.79 to 0.81) providing evidence of convergent construct validity. In addition, the VFS-A-10 was more sensitive to fatigue associated with self-reported hearing difficulties than generic measures. It was also more sensitive than generic measures to variations in fatigue as a function of degree of hearing impairment. CONCLUSIONS: These findings suggest that the VFS-A-10 is a reliable, valid, and sensitive tool for measuring listening-related fatigue in adults. Its brevity, high sensitivity, and good reliability make it appropriate for clinical use. The scale will be useful for identifying those most affected by listening-related fatigue and for assessing benefits of interventions designed to reduce its negative effects.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Hornsby BWY, Camarata S, Cho SJ, et al. Development and Validation of a Brief Version of the Vanderbilt Fatigue Scale for Adults: The VFS-A-10. Ear Hear. 2023. PMID: 37185656. doi:10.1097/AUD.0000000000001369

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。