单孔与多孔da Vinci系统经口机器人手术治疗下咽癌与喉癌的比较
回顾性数据库分析比较da Vinci单孔(SP)与多孔(MP)系统经口机器人手术治疗喉癌与下咽癌的围手术期结果。倾向性评分匹配后112例分析显示,SP组对接时间与操作台时间均缩短,MP组切缘阳性更常见但差异无统计学意义,SP组平均拔管时间延长1.86天。
要点
- SP组对接时间较MP组缩短(8.84±4.67 vs 6.45±3.11分钟;p=.003)。
- SP组操作台时间较MP组缩短(53.91±29.38 vs 42.70±13.72分钟;p=.035)。
- SP组平均拔管时间较MP组延长1.86天(p=.046),其余术后结局无显著差异。
核心结论
- SP系统的安全性特征与既往机型相当,在缩短对接时间方面显示出优势。
- 由于可操作性及术野可视化改善,操作台时间也缩短。
研究设计与样本
- 回顾性数据库分析,纳入2008年至2022年间接受经口机器人手术的成年喉癌与下咽癌患者。
- 共纳入185例患者(SP组56例 vs MP组129例),经倾向性评分匹配后分析112例患者。
主要发现
- 对接时间SP组8.84±4.67分钟 vs MP组6.45±3.11分钟(p=.003)。
- 操作台时间SP组53.91±29.38分钟 vs MP组42.70±13.72分钟(p=.035)。
- 切缘阳性MP组更常见(52% vs 43%;p=.34)。
- 平均拔管时间SP组较MP组延长1.86天(p=.046)。
- 住院时间、肠内喂养时长及经口机器人手术相关并发症分析未见显著差异。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Da Vinci single port (SP) has been recently approved for transoral robotic surgery (TORS). Its characteristics make it particularly feasible for laryngeal and hypopharyngeal surgery. We report our experience comparing intra- and postoperative outcomes, technical advantages, and shortcomings of transoral laryngeal and hypopharyngeal resections performed with the da Vinci SP and the da Vinci Si/Xi systems. STUDY DESIGN: Retrospective database review. SETTING: Single academic tertiary care hospital. METHODS: Subjects included adult patients with laryngeal and hypopharyngeal carcinoma who underwent TORS between 2008 and 2022. The SP and multiport (MP) systems were compared in terms of intraoperative times, short-term postoperative outcomes, and TORS-related complications after a propensity score matching. RESULTS: A total of 185 patients were enrolled (56 SP vs 129 MP patients), and a cohort of 112 patients was analyzed after matching. The docking time was reduced in the SP group (8.84 ± 4.67 vs 6.45 ± 3.11 minutes; p = .003), as well as console time (53.91 ± 29.38 vs 42.70 ± 13.72 minutes; p = .035). Positive margins were more frequent in the MP group (52% vs 43%; p = .34). The mean decannulation time was 1.86 days longer in the SP group (p = .046). No significant differences emerged from the analysis of the duration of hospitalization, enteral feeding, and TORS-related complications. CONCLUSION: SP safety profile is comparable to that of previous models, while it showed advantages in terms of reduced docking times. Console times were also shortened due to improved maneuverability and field visualization.
引用
- Sampieri C, Pirola F, Costantino A, et al. Single-Port Versus Multiport da Vinci System for Transoral Robotic Surgery of Hypopharyngeal and Laryngeal Carcinoma. Otolaryngol Head Neck Surg. 2023. PMID: 36939577. doi:10.1002/ohn.287
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。