便携式睡眠监测设备与多导睡眠图对比的Meta分析
该系统综述与Meta分析纳入24项研究共1644例患者,比较便携式睡眠监测设备与多导睡眠图同步监测的呼吸指标。结果显示,呼吸暂停低通气指数、氧减饱和度指数、呼吸紊乱指数、血氧饱和度和最低血氧饱和度在两种方法间均呈强相关(r=0.888至0.942,均P<0.001);Meta回归显示除血氧饱和度外,其余指标预测相关性显著。作者认为便携式睡眠监测设备可能是有价值的阻塞性睡眠呼吸暂停筛查工具。
要点
- 便携式睡眠监测设备与多导睡眠图的呼吸暂停低通气指数、氧减饱和度指数、呼吸紊乱指数、血氧饱和度和最低血氧饱和度均呈强相关。
- Meta回归显示呼吸暂停低通气指数、氧减饱和度指数、呼吸紊乱指数和最低血氧饱和度预测相关性显著,血氧饱和度不显著。
- 作者认为便携式睡眠监测设备可能是有价值的省时省费的阻塞性睡眠呼吸暂停筛查工具。
核心结论
- 便携式睡眠监测设备与多导睡眠图之间呼吸指标呈强相关,Meta回归结果进一步支持这一结论;作者认为便携式睡眠监测设备可能是有价值的省时省费的阻塞性睡眠呼吸暂停筛查工具。
研究设计与样本
- 系统综述与Meta分析,检索PubMed、Scopus、CINAHL和Cochrane数据库,检索时间从建库至2021年8月,仅纳入对便携式睡眠监测设备与多导睡眠图进行同步监测的研究,共纳入24项研究(N=1644例患者)。
主要发现
- 患者平均年龄49.5±12.0岁(范围13-92),平均体重指数30.4±5.7(范围17-87),男性占69.4%。
- Meta相关分析显示便携式睡眠监测设备与多导睡眠图在呼吸暂停低通气指数(n=655,r=0.888;P<0.001)、氧减饱和度指数(n=241,r=0.942;P<0.001)、呼吸紊乱指数(n=313,r=0.832;P<0.001)、血氧饱和度(n=171,r=0.858;P<0.001)和最低血氧饱和度(n=197,r=0.930;P<0.001)上均呈显著关联。
- Meta回归显示呼吸暂停低通气指数(n=655;r=0.96;P<0.001)、氧减饱和度指数(n=740;r=0.75;P=0.031)、呼吸紊乱指数(n=197;r=0.99;P=0.005)和最低血氧饱和度(n=197;r=0.85;P=0.030)的预测相关性显著,而血氧饱和度(n=171;r=0.31;P=0.692)不显著。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To provide an updated comparison of apnea-hypopnea index (AHI), oxygen desaturation index (ODI), respiratory disturbance index (RDI), oxygen saturation (O2 sat), and lowest oxyhemoglobin saturation (LSAT) measured by portable sleep study devices (PSSDs) compared to polysomnography (PSG). DATA SOURCES: Primary studies were identified through PubMed, Scopus, CINAHL, and Cochrane. REVIEW METHODS: A systematic review was performed by searching databases from inception through August 2021. Only studies examining simultaneous monitoring of a PSSD and PSG were included. Respiratory indices AHI, ODI, RDI, O2 sat, and LSAT was collected Meta-correlations and meta-regressions were conducted to compare sleep variable measurements between PSSD and PSG. RESULTS: A total of 24 studies (N = 1644 patients) were included. The mean age was 49.5 ± 12.0 (range = 13-92), mean body mass index (BMI) was 30.4 ± 5.7 (range = 17-87), and 69.4% were male. Meta-correlation showed significant associations between PSSD and PSG for AHI (n = 655, r = .888; p < .001), ODI (n = 241, r = .942; p < .001), RDI (n = 313, r = .832; p < .001), O2 sat (n = 171, r = .858; p < .001), and LSAT (n = 197, r = .930; p < .001). Meta-regressions indicated significant predictive correlations for AHI (n = 655; r = .96; p < .001), ODI (n = 740; r = .75; p = .031), RDI (n = 197; r = .99; p = .005), and LSAT (n = 197; r = .85; p = .030), but not for O2 sat (n = 171; r = .31; p = .692). CONCLUSIONS: Respiratory indices correlate strongly between PSSD and PSG, which is further supported by meta-regressions results. PSSD might be a valuable cost and time-saving OSA screening tool.
引用
- Cagle JL, Young BD, Shih MC, et al. Portable Sleep Study Device Versus Polysomnography: A Meta-analysis. Otolaryngol Head Neck Surg. 2023. PMID: 36939562. doi:10.1002/ohn.179
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。