文献速递耳科与耳神经

单侧耳聋人工耳蜗使用者在单耳与双耳聆听时的事件相关电位研究

A Study of Event-Related Potentials During Monaural and Bilateral Hearing in Single-Sided Deaf Cochlear Implant Users.
PubMed 文献 · Ear Hear · 2023-01-06

本研究记录10名单侧耳聋人工耳蜗使用者在语义声学奇异任务中的脑电图,比较直接经人工耳蜗、直接经正常听力耳及自由场人工耳蜗开/关四种聆听条件下的任务表现与事件相关电位。直接呈现时正常听力耳任务表现优于人工耳蜗,但N2N4和P3b目标-标准效应无显著差异;自由场中人工耳蜗开启时早期和晚期神经反应增强,但任务表现未改善。

要点

  • 直接呈现时正常听力耳反应时约720毫秒、准确率约93%,优于人工耳蜗约842毫秒、约70%。
  • N2N4和P3b目标-标准效应在正常听力耳与人工耳蜗间无显著差异。
  • 自由场中人工耳蜗开启时目标准确率约95%,与关闭时相近,但反应时略延迟且变异更大。

核心结论

  • 语义奇异任务的行为和神经反应在直接和自由场呈现中均对人工耳蜗敏感。
  • 直接条件下参与者可仅用人工耳蜗完成任务,但表现欠佳且早期神经反应较正常听力耳减弱。
  • 自由场中人工耳蜗的加入与早期和晚期神经反应增强相关,但未带来任务表现改善。

研究设计与样本

  • 记录10名单侧耳聋人工耳蜗使用者(其中4名参与过既往纯音研究)在语义声学奇异任务中的脑电图。
  • 刺激在四种聆听条件下呈现:直接经人工耳蜗、直接经正常听力耳、自由场人工耳蜗开启、自由场人工耳蜗关闭。
  • 检查任务表现(反应时和准确率)以及N1、P2、N2N4和P3b事件相关脑电位,并评估声源定位和噪声下言语理解。

主要发现

  • 直接呈现时,正常听力耳较人工耳蜗反应时更短且变异更小(约720 vs 约842毫秒),目标准确率更高(约93 vs 约70%),N1和P2早期神经反应增强。
  • 直接呈现时,N2N4和P3b目标-标准效应的大小在正常听力耳与人工耳蜗间无显著差异。
  • 自由场中,人工耳蜗开启(FF-On)与关闭(FF-Off)时目标准确率均约95%,FF-On时反应时略但显著延迟且变异更大(约737 vs 约709毫秒)。
  • 自由场中FF-On时早期神经反应和晚期效应也更大。
  • 声源定位和噪声下言语理解(仅S CI N NHE配置)在FF-On时显著更优。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 未来关注双耳听觉的研究应检查噪声条件下的表现和/或使用空间线索,以留出测量双耳获益的余地。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Single-sided deafness (SSD) is characterized by a profoundly deaf ear and normal hearing in the contralateral ear. A cochlear implant (CI) is the only method to restore functional hearing in a profoundly deaf ear. In a previous study, we identified that the cortical processing of a CI signal differs from the normal-hearing ear (NHE) when directly compared using an auditory oddball paradigm consisting of pure tones. However, exactly how the brain integrates the electrical and acoustic signal is not well investigated. This study aims to understand how the provision of the CI in combination with the NHE may improve SSD CI users' ability to discriminate and evaluate auditory stimuli. DESIGN: Electroencephalography from 10 SSD-CI participants (4 participated in the previous pure-tone study) were recorded during a semantic acoustic oddball task, where they were required to discriminate between odd and even numbers. Stimuli were presented in four hearing conditions: directly through the CI, directly to the NHE, or in free field with the CI switched on and off. We examined task-performance (response time and accuracy) and measured N1, P2, N2N4, and P3b event-related brain potentials (ERPs) linked to the detection, discrimination, and evaluation of task relevant stimuli. Sound localization and speech in noise comprehension was also examined. RESULTS: In direct presentation, task performance was superior during NHE compared with CI (shorter and less varied reaction times [~720 versus ~842 msec], higher target accuracy [~93 versus ~70%]) and early neural responses (N1 and P2) were enhanced for NHE suggesting greater signal saliency. However, the size of N2N4 and P3b target-standard effects did not differ significantly between NHE and CI. In free field, target accuracy was similarly high with the CI (FF-On) and without the CI (FF-Off) (~95%), with some evidence of CI interference during FF-On (more variable and slightly but significantly delayed reaction times [~737 versus ~709 msec]). Early neural responses and late effects were also greater during FF-On. Performance on sound localization and speech in noise comprehension (S CI N NHE configuration only) was significantly greater during FF-On. CONCLUSIONS: Both behavioral and neural responses in the semantic oddball task were sensitive to CI in both direct and free-field presentations. Direct conditions revealed that participants could perform the task with the CI alone, although performance was suboptimal and early neural responses were reduced when compared with the NHE. For free-field, the addition of the CI was associated with enhanced early and late neural responses, but this did not result in improved task performance. Enhanced neural responses show that the additional input from the CI is modulating relevant perceptual and cognitive processes, but the benefit of binaural hearing on behavior may not be realized in simple oddball tasks which can be adequately performed with the NHE. Future studies interested in binaural hearing should examine performance under noisy conditions and/or use spatial cues to allow headroom for the measurement of binaural benefit.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Voola M, Nguyen AT, Wedekind A, et al. A Study of Event-Related Potentials During Monaural and Bilateral Hearing in Single-Sided Deaf Cochlear Implant Users. Ear Hear. 2023. PMID: 36706105. doi:10.1097/AUD.0000000000001326

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。