峰度校正累积噪声暴露在评估复杂噪声相关职业性听力损失中的有效性
该横断面调查纳入1404名中国制造业工人,分析峰度校正累积噪声暴露(CNE-K)评估复杂噪声相关职业性听力损失的有效性。峰度是高频噪声性听力损失(HFNIHL%)的关键影响因素(OR=1.18,p<0.05),复杂噪声CNE-K与高斯噪声CNE的logistic曲线几乎重叠,平均差异从8.1%降至0.4%,提示CNE-K可能比单独CNE更有效。
要点
- 峰度是高频噪声性听力损失的关键影响因素(OR=1.18,p<0.05)。
- 复杂噪声CNE-K与高斯噪声CNE的logistic曲线几乎重叠,平均差异从8.1%降至0.4%。
- 峰度对NIPTS346的贡献仅次于八小时连续等效A声级(LAeq,8h)。
核心结论
- 峰度作为噪声时间结构的间接指标,是职业性噪声性听力损失的重要危险因素。
- 峰度校正CNE指标可能比单独CNE更有效地评估复杂噪声相关的职业性听力损失风险。
研究设计与样本
- 横断面调查纳入1404名来自典型制造业的中国制造业工人。
- 收集一般人口学特征、噪声暴露数据及3、4、6 kHz噪声性永久阈移(NIPTS346)并分析。
- 采用基于年龄、性别、行业或岗位的分层分析,以复杂噪声CNE-K与HFNIHL%及高斯噪声CNE与HFNIHL%两条logistic曲线的重叠程度评估CNE-K有效性。
主要发现
- 二元logistic回归显示,除年龄、性别、暴露时长和八小时连续等效A声级(LAeq,8h)外,峰度是影响工人HFNIHL%的关键因素(OR=1.18,p<0.05),其OR随峰度值增加而升高。
- 多元线性回归显示,峰度对NIPTS346的贡献仅次于LAeq,8h。
- 调整年龄、性别和CNE后,复杂噪声在3、4、6、8 kHz频率导致的NIHL风险高于高斯噪声(p<0.05)。
- 随峰度增加,听力图切迹加深,切迹开始加深的频率从3 kHz移至1 kHz。
- 复杂噪声CNE-K与HFNIHL%的logistic曲线几乎与高斯噪声CNE和HFNIHL%的曲线重叠,两曲线间HFNIHL%平均差异从8.1%降至0.4%。
关键数值与推荐
- 峰度影响HFNIHL%的OR=1.18(p<0.05)。
- 复杂噪声与高斯噪声NIHL风险比较,调整年龄、性别和CNE后p<0.05(3、4、6、8 kHz)。
- 两条logistic曲线间HFNIHL%平均差异从8.1%降至0.4%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Occupational noise-induced hearing loss (NIHL) is one of the most prevalent occupational diseases worldwide. Few studies have been reported on applying kurtosis-adjusted noise energy (e.g., kurtosis-adjusted cumulative noise exposure, CNE-K) as a joint indicator for assessing NIHL. This study aimed to analyze the effectiveness of CNE-K in assessing occupational hearing loss associated with complex noise in typical manufacturing industries. DESIGN: A cross-sectional survey of 1404 Chinese manufacturing workers from typical manufacturing industries was conducted. General demographic characteristics, noise exposure data, and noise-induced permanent threshold shifts (NIPTS) at 3, 4, and 6 kHz (NIPTS 346 ) were collected and analyzed. The role of kurtosis in high-frequency noise-induced hearing loss (HFNIHL) was also analyzed. The degree of overlap of the two logistic curves (i.e., between complex noise CNE-K and HFNIHL%, and between Gaussian noise CNE and HFNIHL%) was used to evaluate the effectiveness of CNE-K, using a stratified analysis based on age, sex, industry, or job type. RESULTS: The binary logistic regression analysis showed that in addition to age, sex, exposure duration, and Eight-hour Continuous Equivalent A-weighted Sound Pressure Level (L Aeq,8h ), kurtosis was a key factor influencing HFNIHL% in workers (odds ratio = 1.18, p < 0.05), and its odds ratio increased with an increase in kurtosis value. Multiple linear regression analysis demonstrated that the contribution of kurtosis to NIPTS 346 was second to L Aeq,8h . Complex noise led to a higher risk of NIHL than Gaussian noise at frequencies of 3, 4, 6, and 8 kHz after adjusting for age, sex, and CNE ( p < 0.05). As kurtosis increased, the notch in the audiogram became deeper, and the frequency at which the notch began to deepen shifted from 3 to 1 kHz. The logistic curve between complex noise CNE-K and HFNIHL% nearly overlapped with that between Gaussian noise CNE and HFNIHL%, and the average difference in HFNIHL% between the two curves decreased from 8.1 to 0.4%. Moreover, the decrease of average difference in HFNIHL% between the two logistic curves was evident in several subgroups, such as male workers, aged <30 and 30 to 50 years, furniture and woodworking industries and gunning and nailing job types with relatively high kurtosis values. CONCLUSIONS: Kurtosis, as an indirect metric of noise temporal structure, was an important risk factor for occupational NIHL. Kurtosis-adjusted CNE metric could be more effective than CNE alone in assessing occupational hearing loss risk associated with complex noise.
引用
- Xin J, Shi Z, Qian P, et al. Effectiveness of Kurtosis-Adjusted Cumulative Noise Exposure in Assessing Occupational Hearing Loss Associated With Complex Noise. Ear Hear. 2023. PMID: 36629325. doi:10.1097/AUD.0000000000001327
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。