文献速递耳科与耳神经

成年语后聋人工耳蜗使用者听神经对幅度调制的敏感性与知觉幅度调制速率辨别敏感性及言语感知表现之间的关系

Relationships Between the Auditory Nerve Sensitivity to Amplitude Modulation, Perceptual Amplitude Modulation Rate Discrimination Sensitivity, and Speech Perception Performance in Postlingually Deafened Adult Cochlear Implant Users.
PubMed 文献 · Ear Hear · 2022-11-07

本研究纳入18名语后聋成年人工耳蜗使用者(23耳),评估听神经对20 Hz幅度调制(AM)的编码显著性与AM速率辨别阈值(AMRDT)及辅音-核心-辅音(CNC)词得分的关系。结果显示MRAR与AMRDT无关联,CNC词得分(安静或+10 dB SNR)与MRAR或AMRDT均无显著相关,仅用单个电极位置的结果可能得出错误结论。

要点

  • 听神经对AM线索的敏感性差异不是同一使用者不同刺激位点AMRDT变异的主要因素。
  • 听神经对AM的敏感性本身可能不是语后聋成年人工耳蜗使用者安静或+10 dB SNR下CNC词感知的关键因素。
  • 仅用单个电极位置的电生理或心理物理结果与言语感知得分相关可能导致不准确甚至错误的结论。

核心结论

  • 听神经对AM线索的敏感性差异不是同一人工耳蜗使用者不同刺激位点AMRDT变异的主要因素。
  • 听神经对AM的敏感性本身可能不是语后聋成年人工耳蜗使用者安静或+10 dB SNR下CNC词感知的关键因素。
  • 仅用单个电极位置的电生理或心理物理结果与言语感知得分相关可能导致不准确甚至错误的结论。

研究设计与样本

  • 研究纳入18名语后聋成年人工耳蜗使用者(Cochlear Nucleus装置),包括5名双侧植入患者,共23耳。
  • 在23耳中,每耳在7个电极位置用电诱发复合动作电位(eCAP)评估听神经对20 Hz AM的神经编码,以调制响应幅度比(MRAR)量化。
  • 在16耳中用三选一强制选择程序评估20 Hz调制AMRDT,目标心理测量函数正确率79.4%,每耳最多5个电极位置。
  • 所有23耳测量安静和+10 dB SNR下语音形状噪声中的CNC词得分。
  • 用线性混合模型(LMM)评估单个电极位置MRAR/AMRDT与CNC词得分的关系,用Spearman秩相关评估MRAR和AMRDT的方差及多电极平均值与CNC词得分的关联。

主要发现

  • MRAR与AMRDT之间无关联。
  • 仅用随机选择的单个电极位置测量的MRAR和AMRDT评估其与CNC词得分的关联可能导致相反结论。
  • LMM和Spearman秩相关均显示安静或10 dB SNR下CNC词得分与MRAR或AMRDT无显著相关。
  • Spearman秩相关显示MRAR和AMRDT的方差与安静或噪声下CNC词得分无显著相关。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: This study assessed the relationships between the salience of amplitude modulation (AM) cues encoded at the auditory nerve (AN), perceptual sensitivity to changes in AM rate (i.e., AM rate discrimination threshold, AMRDT), and speech perception scores in postlingually deafened adult cochlear implant (CI) users. DESIGN: Study participants were 18 postlingually deafened adults with Cochlear Nucleus devices, including five bilaterally implanted patients. For each of 23 implanted ears, neural encoding of AM cues at 20 Hz at the AN was evaluated at seven electrode locations across the electrode array using electrophysiological measures of the electrically evoked compound action potential (eCAP). The salience of AM neural encoding was quantified by the Modulated Response Amplitude Ratio (MRAR). Psychophysical measures of AMRDT for 20 Hz modulation were evaluated in 16 ears using a three-alternative, forced-choice procedure, targeting 79.4% correct on the psychometric function. AMRDT was measured at up to five electrode locations for each test ear, including the electrode pair that showed the largest difference in the MRAR. Consonant-Nucleus-Consonant (CNC) word scores presented in quiet and in speech-shaped noise at a signal to noise ratio (SNR) of +10 dB were measured in all 23 implanted ears. Simulation tests were used to assess the variations in correlation results when using the MRAR and AMRDT measured at only one electrode location in each participant to correlate with CNC word scores. Linear Mixed Models (LMMs) were used to evaluate the relationship between MRARs/AMRDTs measured at individual electrode locations and CNC word scores. Spearman Rank correlation tests were used to evaluate the strength of association between CNC word scores measured in quiet and in noise with (1) the variances in MRARs and AMRDTs, and (2) the averaged MRAR or AMRDT across multiple electrodes tested for each participant. RESULTS: There was no association between the MRAR and AMRDT. Using the MRAR and AMRDT measured at only one, randomly selected electrode location to assess their associations with CNC word scores could lead to opposite conclusions. Both the results of LMMs and Spearman Rank correlation tests showed that CNC word scores measured in quiet or at 10 dB SNR were not significantly correlated with the MRAR or AMRDT. In addition, the results of Spearman Rank correlation tests showed that the variances in MRARs and AMRDTs were not significantly correlated with CNC word scores measured in quiet or in noise. CONCLUSIONS: The difference in AN sensitivity to AM cues is not the primary factor accounting for the variation in AMRDTs measured at different stimulation sites within individual CI users. The AN sensitivity to AM per se may not be a crucial factor for CNC word perception in quiet or at 10 dB SNR in postlingually deafened adult CI users. Using electrophysiological or psychophysical results measured at only one electrode location to correlate with speech perception scores in CI users can lead to inaccurate, if not wrong, conclusions.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. He S, Skidmore J, Koch B, et al. Relationships Between the Auditory Nerve Sensitivity to Amplitude Modulation, Perceptual Amplitude Modulation Rate Discrimination Sensitivity, and Speech Perception Performance in Postlingually Deafened Adult Cochlear Implant Users. Ear Hear. 2022. PMID: 36342278. doi:10.1097/AUD.0000000000001289

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。