文献速递耳科与耳神经

基于80词修正押韵测试制定循证军事听觉适岗标准

Developing an Evidence-Based Military Auditory Fitness-for-Duty Standard Based on the 80-Word Modified Rhyme Test.
PubMed 文献 · Ear Hear · 2022-11-03

本研究招募约2400名听力损失程度不同的服役人员,在年度听力保护评估时完成80词修正押韵测试(MRT 80),并完成一项或多项基于高仿真军事训练环境录音的操作性相关听觉任务。结果显示,结合MRT 80两表正确百分比(即MRT 160)与较好耳2 kHz阈值信息的截断标准,通常能将听力损失者分为操作性听觉测试表现较好与较差两类。该标准与美国陆军近期采用的新听力剖面标准似可提供有效的循证方法,识别听力关键军事任务表现风险最高的听力损失服役人员。

要点

  • 约2400名不同听力损失程度的服役人员完成MRT 80及操作性相关听觉任务。
  • 结合MRT 160正确百分比与较好耳2 kHz阈值的截断标准可区分操作表现好与差者。
  • 该标准与美国陆军新采用的听力剖面标准似可有效识别听力关键任务表现风险最高者。

核心结论

  • 所提出的选择标准连同美国陆军近期采用的新听力剖面标准,似可提供有效的循证方法,识别听力关键军事任务表现风险最高的听力损失服役人员。

研究设计与样本

  • 研究招募约2400名听力损失程度不同的服役人员,在年度听力保护评估时完成MRT 80,并完成一项或多项基于高仿真军事训练环境录音的操作性相关听觉任务。

主要发现

  • 结合MRT 80两表正确百分比(即MRT 160)与较好耳2 kHz阈值信息的截断标准,通常能将听力损失者分为操作性听觉测试表现较好与较差两类。
  • 该结果与当前军事采购标准一致,后者将MRT认定为评估无线电、耳机及其他通信设备言语清晰度的首选测试。
  • 该结果也与先前在高保真军事模拟中进行的研究一致,这些研究显示MRT表现与操作结果之间存在显著相关性。

关键数值与推荐

  • 截断标准结合MRT 80两表正确百分比(即MRT 160)与较好耳2 kHz阈值信息,通常可区分操作性听觉测试表现较好与较差者。
  • 当前军事采购标准将MRT认定为评估无线电、耳机及其他通信设备言语清晰度的首选测试。

临床怎么用

  • 原文未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: One important function of military audiology is to conduct evaluations of service members (SMs) with hearing loss to ensure they are fit for deployment in dangerous operational environments. The objective of this study was to establish evidence-based auditory fitness-for-duty criteria based on speech-in-noise performance on the 80- and 160-word clinical versions of the Modified Rhyme Test (MRT 80 and MRT 160 ). DESIGN: Approximately 2400 SMs with various levels of hearing loss were recruited to complete the MRT 80 in conjunction with their annual hearing conservation evaluations. These SMs were also asked to perform one or more operationally-relevant listening tasks based on audio recordings made in highly realistic military training environments. The scores on these tests were compared to determine how well a proposed cutoff criterion for the MRT 80 was able to identify individuals who are hard of hearing with an exceptionally high risk of abnormally poor performance on operationally-relevant hearing tasks. RESULTS: The results show that a cutoff criterion that combines the percent correct score on two lists of the MRT 80 (i.e. MRT 160 ) with information about the better-ear threshold at 2 kHz is generally able to separate listeners with hearing loss into those who are likely to perform relatively well on operational listening tests and those who are likely to perform poorly on these tasks. This is consistent with current military acquisition standards, which identify the MRT as the preferred test for evaluating speech intelligibility for radios, headsets, and other communication equipment. It is also consistent with prior studies conducted in high-fidelity military simulations which have shown a significant correlation between MRT performance and operational outcomes. CONCLUSIONS: The proposed selection criteria, along with the new hearing profile standards that were recently adopted by the US Army, appear to provide an effective evidence-based methodology for identifying those SMs with hearing loss who are most at risk for poor performance on hearing-critical military tasks.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Brungart DS, Sheffield BM, Galloza H, et al. Developing an Evidence-Based Military Auditory Fitness-for-Duty Standard Based on the 80-Word Modified Rhyme Test. Ear Hear. 2022. PMID: 36323655. doi:10.1097/AUD.0000000000001270

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。