德语儿童人工耳蜗植入后言语与非言语智力的纵向发展:基于韦氏测验的初步研究

Longitudinal Development of Verbal and Nonverbal Intelligence After Cochlear Implantation According to Wechsler Tests in German-speaking Children: A Preliminary Study.
PubMed 文献 · Ear Hear · 2022-09-27

本研究纳入16例先天性听力损失并接受单侧或双侧人工耳蜗植入的儿童,在植入后约3年及约2年后各进行一次智力评估。结果显示言语智商与非言语智商均随时间增长,言语智商增幅更大,第二次评估时两者水平相当;两次评估间隔与第二次言语智商显著相关,教育模式与第二次非言语智商显著相关。作者认为小样本结果提示人工耳蜗植入儿童在植入后约3年智力能力可与正常听力同龄人相当,并建议进一步研究。

要点

  • 16例先天性听力损失儿童在人工耳蜗植入后约3年及约2年后接受韦氏智力测验纵向评估。
  • 言语智商与非言语智商均随时间增长,言语智商增幅更大,第二次评估时两者水平相当。
  • 两次评估间隔与第二次言语智商显著相关,教育模式与第二次非言语智商显著相关。

核心结论

  • 尽管样本量小,结果明确提示人工耳蜗植入儿童在初次植入后约3年时可达到与正常听力同龄人相当的智力能力,并在随后2年继续改善。
  • 作者建议进一步研究聚焦于入学年龄前后的言语智商,将其作为进一步发展和制定个体化教育方案的预测指标。

研究设计与样本

  • 纳入16例先天性听力损失并接受单侧或双侧人工耳蜗植入、在入学年龄前后完成至少两次智力评估的儿童。
  • 第一次评估在人工耳蜗植入后约3年进行(实足年龄范围3.93至7.03岁),第二次评估在第一次评估后约2年进行。
  • 使用同一测验家族中相应的标准化和常模化测验(韦氏学前和小学智力量表和/或韦氏儿童智力量表)联合分析不同年龄儿童的言语智商和非言语智商。

主要发现

  • 纵向发展方面,言语智商和非言语智商均随时间增长,但言语智商随时间增幅更大。
  • 第二次测量时,言语智商和非言语智商处于相当水平。
  • 观察到较强的个体间差异。
  • 两次评估之间的间隔与第二次测量时的言语智商显著相关,因而与言语智商随时间增益显著相关。
  • 教育模式(普通幼儿园/学校 vs. 特殊幼儿园/学校)与第二次评估时的非言语智商显著相关。

临床怎么用

  • 作者建议进一步研究聚焦于入学年龄前后的言语智商,将其作为进一步发展和制定个体化教育方案的预测指标。

局限性

  • 样本量小。
  • 作者建议进一步研究聚焦于入学年龄前后的言语智商,将其作为进一步发展和制定个体化教育方案的预测指标。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Intelligence as a construct of cognitive abilities is the basis of knowledge and skill acquisition and the main predictor of academic achievement. As a broad construct, it is usually divided into subdomains, such as nonverbal and verbal intelligence. Verbal intelligence is one domain of intelligence but is not synonymous with specific linguistic abilities like grammar proficiency. We aim to address the general expectation that early cochlear implantation enables children who are hard of hearing to develop comprehensively, including with respect to verbal intelligence. The primary purpose of this study is to trace the longitudinal development of verbal and nonverbal intelligence in children with cochlear implants (CIs). DESIGN: Sixteen children with congenital hearing loss who received unilateral or bilateral implants and completed at least two intelligence assessments around the age of school entrance were included in the study. The first assessment was performed around 3 years after CI fitting (chronological age range: 3.93 to 7.03 years). The second assessment was performed approximately 2 years after the first assessment. To analyze verbal and nonverbal IQ in conjunction and across children at different ages, we used corresponding standardized and normalized tests from the same test family (Wechsler Preschool and Primary Scale of Intelligence and/or Wechsler Intelligence Scale for Children). RESULTS: Regarding longitudinal development, both verbal and nonverbal IQ increased, but verbal IQ increased more substantially over time. At the time of the second measurement, verbal and nonverbal IQ were on a comparable level. Nevertheless, we also observed strong inter-individual differences. The duration between both assessments was significantly associated with verbal IQ at the second measurement time point and thus with verbal IQ gain over time. Education mode (regular vs. special kindergarten/school) was significantly correlated with nonverbal IQ at the second assessment time point. CONCLUSIONS: The results, despite the small sample size, clearly suggest that children with CIs can achieve intellectual abilities comparable to those of their normal-hearing peers by around the third year after initial CI fitting, and they continue to improve over the following 2 years. We recommend further research focusing on verbal IQ assessed around the age of school entrance to be used as a predictor for further development and for the establishment of an individual educational program.