药物诱导睡眠内镜下视觉评估咽部开放压力的准确性与可靠性
前瞻性观察研究纳入100例阻塞性睡眠呼吸暂停患者,77例完成全部评估,比较药物诱导睡眠内镜下视觉评估与气流监测测得的咽部开放压力(PhOP)。两名盲法独立评估者的视觉DISE-PhOP均与气流法等效(差异在±1 cm H2O以内),评估者间组内相关系数为0.895(95%CI 0.84-0.932)。
要点
- 视觉评估的DISE-PhOP与气流法测值等效,差异均在±1 cm H2O以内。
- 两名评估者间信度良好至优秀,组内相关系数0.895(95%CI 0.84-0.932)。
- 视觉DISE-PhOP可作为临床DISE中标准化的客观参数。
核心结论
- DISE-PhOP作为上气道塌陷性指标,视觉评估与气流法测值等效,且评估者间信度高,支持其作为临床DISE标准化客观参数被采用。
研究设计与样本
- 前瞻性观察研究,纳入100例接受药物诱导睡眠内镜的阻塞性睡眠呼吸暂停患者,77例完成全部评估。
- 患者接受气流监测和鼻持续气道正压滴定,分别确定视觉与气流法的咽部开放压力(PhOP)。
- 视觉DISE-PhOP由2名盲法独立评估者判定,定义为视觉确认气道塌陷(包括打鼾)消失时的压力。
- 气流法DISE-PhOP定义为消除吸气流量限制的最小有效持续气道正压。
主要发现
- 人群以男性为主(74%),平均年龄54.8岁,体重指数30.1 kg/m2,呼吸暂停低通气指数30.7次/小时。
- 等效性检验显示两名评估者的视觉DISE-PhOP与气流法DISE-PhOP差异均在±1 cm H2O以内(-0.43至0.09 cm H2O和-0.32至0.48 cm H2O)。
- 两名评估者间视觉DISE-PhOP的组内相关系数为0.895(95%CI 0.84-0.932)。
关键数值与推荐
- 视觉与气流法DISE-PhOP的等效性界值设为±1 cm H2O,采用双侧单侧T检验(TOST)。
- 评估者间信度采用组内相关系数评价,结果为0.895(95%CI 0.84-0.932)。
临床怎么用
- 原文结论支持将视觉评估的DISE-PhOP作为临床DISE中标准化的客观参数采用。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To examine the accuracy and interrater reliability of a visually assessed vs airflow-based measure of pharyngeal collapsibility obtained in patients with obstructive sleep apnea undergoing drug-induced sleep endoscopy (DISE). STUDY DESIGN: Prospective observational study. SETTING: Academic tertiary care practice. METHODS: Patients underwent DISE with airflow monitoring and nasal positive airway pressure titration to determine visual and airflow-based levels of pharyngeal opening pressure (PhOP). Visual DISE-PhOP was assessed by 2 blinded independent raters and defined as the pressure at which visual confirmation of airway collapse, including snoring, was abolished. Airflow-based DISE-PhOP was defined as the minimally effective positive airway pressure that abolished inspiratory flow limitation. Equivalence testing between visual and airflow DISE-PhOP of each rater was performed with the two one sided T-test (TOST) with an a priori equivalence bound of ±1 cm H2 O. Interrater reliability was evaluated with the intraclass correlation coefficient. RESULTS: One hundred patients were enrolled in the study and 77 completed the full evaluation. The population was predominantly male (74%) with an average age of 54.8 years, body mass index of 30.1 kg/m2 , and apnea-hypopnea index of 30.7 events/h. Equivalence testing showed that both raters were within ±1 cm H2 O of airflow-based DISE-PhOP (-0.43 to 0.09 cm H2 O and -0.32 to 0.48 cm H2 O). Interrater reliability of visual DISE-PhOP between the raters was also good to excellent with an intraclass correlation coefficient of 0.895 (95% CI, 0.84-0.932). CONCLUSION: DISE-PhOP, a measure of upper airway collapsibility, was equivalent between airflow-based and visual assessments with strong interrater reliability, supporting its adoption as a standardized objective parameter in clinical DISE.
引用
- Yu JL, Thuler E, Seay EG, et al. The Accuracy and Reliability of Visually Assessed Pharyngeal Opening Pressures During Drug-Induced Sleep Endoscopy. Otolaryngol Head Neck Surg. 2023. PMID: 36040822. doi:10.1177/01945998221120793
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。