人工耳蜗植入后言语识别能力的纵向变化:系统综述与Meta分析
该系统综述与Meta分析纳入22篇文献共1954例语后聋成人人工耳蜗植入者,评估植入前至术后多个时间点的言语识别得分变化。结果显示,安静下单词、安静下句子和噪声下句子得分从术前至术后3个月均显著提高,3至12个月得分继续上升但未达统计学显著。
要点
- 语后聋成人人工耳蜗植入者言语识别得分在术后3个月内显著提高。
- 术后3至12个月得分虽继续上升,但无进一步统计学显著改善。
- 个体间差异较大,需未来研究解释差异来源。
核心结论
- 平均言语识别得分在术后前3个月内显著改善,3个月后无进一步统计学显著改善。
- 个体间差异较大,未来研究需解释这些个体差异的来源。
研究设计与样本
- 系统综述与Meta分析,纳入报告语后聋成人人工耳蜗植入者植入前及至少两个术后时间点言语识别得分的英文文献。
- 共纳入22篇文献,代表1954例患者。
主要发现
- 术前至术后3个月,安静下单词得分平均差异为37.4%(95%CI [34.7%, 40.7%]),安静下句子为49.4%(95%CI [44.9%, 53.9%]),噪声下句子为30.8%(95%CI [25.2%, 36.4%])。
- 术前至术后3个月,安静下CNC单词为37.1%(95%CI [33.8%, 40.4%]),安静下HINT句子为46.5%(95%CI [37.0%, 56.0%]),安静下AzBio句子为45.9%(95%CI [44.2%, 47.5%]),噪声下AzBio句子为26.4%(95%CI [18.6%, 34.2%])。
- 噪声下HINT句子从术前至术后3个月改善35.1%(95%CI [30.0%, 40.3%]),从3至12个月改善15.5%(95%CI [7.2%, 23.8%])。
- 术后3至12个月得分继续增加但未达统计学显著。
临床怎么用
- 原文未据此给出推荐。
局限性
- 未来研究需解释个体差异的来源。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To examine patterns of change and plateau in speech recognition scores in postlingually hearing impaired adult cochlear implant recipients. The study also examines variations in change patterns for different speech materials and testing conditions. STUDY DESIGN: Used systematic review with meta-analysis. METHODS: Articles in English reporting speech recognition scores of adults with postlingual hearing loss at pre-implantation and at least two post-implantation time points were included. Statistically significant changes were determined by meta-analysis and the 95% confidence interval. RESULTS: A total of 22 articles representing 1954 patients were included. Meta-analysis of mean difference demonstrated significant improvements in speech recognition score for words in quiet (37.4%; 95% confidence interval [34.7%, 40.7%]), sentences in quiet (49.4%; 95% confidence interval [44.9%, 53.9%]), and sentences in noise (30.8%; 95% confidence interval [25.2%, 36.4%]) from pre-op to 3 months. Scores continued to increase from 3 to 12 months but did not reach significance. Similarly, significant improvements from pre-op to 3 months were observed for consonant nucleus consonant (CNC) words in quiet (37.1%; 95% confidence interval [33.8%, 40.4%]), hearing in noise test (HINT) sentences in quiet (46.5%; 95% confidence interval [37.0%, 56.0%]), AzBio sentences in quiet (45.9%; 95% confidence interval [44.2%, 47.5%]), and AzBio sentences in noise (26.4%; 95% confidence interval [18.6%, 34.2%]). HINT sentences in noise demonstrated improvement from pre-op to 3 months (35.1%; 95% confidence interval [30.0%, 40.3%]) and from 3 to 12 months (15.5%; 95% confidence interval [7.2%, 23.8%]). CONCLUSIONS: Mean speech recognition scores demonstrate significant improvement within the first 3 months, with no further statistically significant improvement after 3 months. However, large individual variation should be expected and future research is needed to explain the sources of these individual differences. Laryngoscope, 133:1014-1024, 2023.
引用
- Ma C, Fried J, Nguyen SA, et al. Longitudinal Speech Recognition Changes After Cochlear Implant: Systematic Review and Meta-analysis. Laryngoscope. 2022. PMID: 36004817. doi:10.1002/lary.30354
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。