声带注射成形术后咳嗽气流与声学变化
前瞻性干预研究纳入25例单侧声带麻痹、瘫痪或萎缩所致声门闭合不全患者,注射成形术后咳嗽呼气峰流速上升时间平均变化-0.03秒(P=0.04),咳嗽容积加速度平均变化13.1 L/s²(P=0.03),提示咳嗽有效性改善;咳嗽声学与气流参数相关性弱。
要点
- 注射成形术后咳嗽呼气峰流速上升时间较术前平均缩短0.03秒(P=0.04)。
- 注射成形术后咳嗽容积加速度较术前平均增加13.1 L/s²(P=0.03)。
- 咳嗽声学能量与峰流速上升时间呈弱相关(系数-0.31,P=0.04)。
核心结论
- 声带注射成形术可能通过改善咳嗽有效性帮助声门闭合不全患者避免误吸,咳嗽气流改善可能通过咳嗽声追踪。
研究设计与样本
- 前瞻性干预研究,纳入25例单侧声带麻痹、瘫痪或萎缩所致声门闭合不全并计划行声带注射成形术的患者,其中22例完成咳嗽声音记录。
主要发现
- 注射成形术后咳嗽呼气峰流速上升时间较术前平均变化-0.03秒(标准差0.06,P=0.04)。
- 注射成形术后咳嗽容积加速度较术前平均变化13.1 L/s²(标准差33.9,P=0.03)。
- 咳嗽声学参数与气流参数相关性弱:呼气峰流速上升时间与声学能量相关系数-0.31(P=0.04),与峰值功率密度相关系数-0.35(P=0.02)。
局限性
- 证据等级为3级。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE/HYPOTHESIS: We explored the following hypotheses in a cohort of patients undergoing injection laryngoplasty: (1) glottic insufficiency affects voluntary cough airflow dynamics and restoring glottic competence may improve parameters of cough strength, (2) cough strength can be inferred from cough acoustic signal, and (3) glottic competence changes cough sounds and correlates with spectrogram morphology. STUDY TYPE/DESIGN: Prospective interventional study. METHODS: Subjects with glottic insufficiency secondary to unilateral vocal fold paresis, paralysis, or atrophy, and scheduled for injection laryngoplasty completed an instrumental assessment of voluntary cough airflow using a pneumotachometer and a protocolized voluntary cough sound recording. A Wilcoxon signed-rank test was used to compare the differences between pre- and post-injection laryngoplasty in airflow and acoustic measures. A Spearman rank-order correlation was used to evaluate the association between airflow and acoustic cough measures. RESULTS: Twenty-five patients (13F:12M, mean age 68.8) completed voluntary cough airflow measurements and 22 completed cough sound recordings. Following injection laryngoplasty, patients had a statistically significant decreased peak expiratory flow rise time (PEFRT) (mean change: -0.03 s, SD: 0.06, p = 0.04) and increased cough volume acceleration (mean change: 13.1 L/s2 , SD: 33.9, p = 0.03), suggesting improved cough effectiveness. Correlation of cough acoustic measures with airflow measures showed a weak relationship between PEFRT and acoustic energy (coefficient: -0.31, p = 0.04) and peak power density (coefficient: -0.35, p = 0.02). CONCLUSIONS: Our study thus indicates that injection laryngoplasty may help avert aspiration in patients with glottic insufficiency by improving cough effectiveness and that improved cough airflow measures may be tracked with cough sounds. LEVEL OF EVIDENCE: 3 Laryngoscope, 133:S1-S14, 2023.
引用
- Rameau A, Andreadis K, German A, et al. Changes in Cough Airflow and Acoustics After Injection Laryngoplasty. Laryngoscope. 2022. PMID: 35723533. doi:10.1002/lary.30255
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。