临床听力正常儿童仍存在扩展高频听力损害
研究纳入542名4至19岁临床听力图正常儿童,将扩展高频(EHF > 8 kHz)任一频率阈值大于20 dB定义为EHF损害,共38例。病例对照分析显示,EHF损害儿童多说话者噪声下言语识别阈值更高(估计值2.14 dB,95%CI 1.36至3.92,效应量小),畸变产物耳声发射总体幅度更低(估计值-2.47 dB,95%CI -4.60至-0.73,效应量中等),标准频率纯音平均阈值相对更高(估计值3.68 dB,95%CI 2.56至4.80,效应量小)。
要点
- 临床听力图正常的儿童中,扩展高频听力损害常见,且可无中耳炎病史。
- EHF损害与噪声下言语识别变差及标准频率耳蜗功能亚临床缺陷相关。
- 研究强调临床有必要识别儿童的扩展高频听力损害。
核心结论
- 扩展高频听力损害在临床听力正常的儿童中常见,且可无中耳炎病史。
- EHF损害与噪声下言语识别变差及听力阈值正常低频区的亚临床耳蜗缺陷相关。
- 本研究强调临床有必要识别儿童的EHF损害。
研究设计与样本
- 志愿者样本542名4至19岁临床听力图正常者接受测试。
- 被判定为EHF损害者进入后续病例对照研究。
- EHF损害定义为10、12.5或16 kHz中至少一个频率听力阈值大于20 dB。
- 采用数字三联测验测量多说话者 babble 噪声下的言语识别阈值。
- 测量f2=2、3、4、5 kHz的畸变产物耳声发射以评估耳蜗功能。
主要发现
- EHF阈值与标准频率范围阈值同样可靠。
- 38名儿童存在EHF听力损害,其临床听力图正常。
- EHF损害儿童的平均言语识别阈值高于EHF敏感正常儿童(估计值2.14 dB,95%CI 1.36至3.92,效应量小)。
- EHF损害儿童的畸变产物耳声发射总体幅度低于EHF正常儿童(估计值-2.47 dB,95%CI -4.60至-0.73,效应量中等)。
- EHF损害儿童的标准听力频率纯音平均阈值相对高于EHF正常儿童(估计值3.68 dB,95%CI 2.56至4.80,效应量小)。
关键数值与推荐
- EHF损害定义为10、12.5或16 kHz中至少一个频率听力阈值大于20 dB。
- EHF损害儿童言语识别阈值估计值2.14 dB(95%CI 1.36至3.92),效应量小。
- EHF损害儿童畸变产物耳声发射幅度估计值-2.47 dB(95%CI -4.60至-0.73),效应量中等。
- EHF损害儿童标准频率纯音平均阈值估计值3.68 dB(95%CI 2.56至4.80),效应量小。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Pediatric hearing impairment, regardless of degree and type, has a detrimental effect on speech perception, cognition, oral language development, academic outcomes, and literacy. Hearing assessment in the clinic is limited to 8 kHz although humans can hear up to 20 kHz. Hearing impairment in the extended high frequencies (EHFs > 8 kHz) can occur despite clinically normal hearing. However, to date, the nature and effects of EHF hearing impairment in children remain unknown. The goals of the present study were to determine the effects of EHF hearing impairment on speech-in-noise recognition in children and to examine whether hearing impairment in the EHFs is associated with altered cochlear functioning in the standard frequencies. DESIGN: A volunteer sample of 542 participants (4 to 19 years) with clinically normal audiograms were tested. Participants identified with EHF impairment were assigned as cases in a subsequent case-control study. EHF loss was defined as hearing thresholds greater than 20 dB in at least one EHFs (10, 12.5, or 16 kHz). Speech recognition thresholds in multi-talker babble were measured using the digit triplet test. Distortion product otoacoustic emissions ( f2 = 2, 3, 4, and 5 kHz) were measured to assess cochlear functioning. RESULTS: Thresholds in the EHFs were as reliable as those in the standard frequency range. Thirty-eight children had EHF hearing impairment regardless of a clinically normal audiogram. A linear mixed-effects model revealed that children with EHF hearing impairment had higher (poorer) mean speech recognition threshold than children with normal EHF sensitivity ( estimate = 2.14 dB, 95% CI: 1.36 to 3.92; effect size = small). The overall magnitude of distortion product otoacoustic emissions was lower for children with EHF impairment ( estimate = -2.47 dB, 95% CI: -4.60 to -0.73; effect size = medium). In addition, the pure-tone average for standard audiometric frequencies was relatively higher for EHF-impaired children ( estimate = 3.68 dB, 95% CI: 2.56 to 4.80; effect size = small). CONCLUSIONS: Hearing impairment in the EHFs is common in children despite clinically normal hearing and can occur without a history of otitis media. EHF impairment is associated with poorer speech-in-noise recognition and preclinical cochlear deficits in the lower frequencies where hearing thresholds are normal. This study highlights the clinical need to identify EHF impairments in children.