阈值均衡噪声测试揭示听功能超阈值损失,甚至见于「正常」听力图范围
研究纳入112名经听力学筛查为正常或轻度感音神经性听力损失的参与者(年龄32至74岁),在0.75、1、3、4 kHz四个频率及高于纯音绝对阈值12和24 dB两个感觉级进行阈值均衡噪声(TEN(HL))测试。结果显示各频率和测试级下TEN阈值升高与绝对阈值呈强正相关,且在绝对阈值≤15 dB HL的「正常」听力范围内仍可观察到该相关;TEN测试中处于「通过」与「失败」之间的结果主要由非内毛细胞相关过程主导。
要点
- TEN测试中掩蔽阈值升高与绝对阈值在所有频率和测试级呈强正相关。
- 在绝对阈值≤15 dB HL的「正常」听力范围内仍可观察到该相关性。
- TEN测试「通过」与「失败」之间的灰区信息主要不反映内毛细胞功能。
核心结论
- 使用临床TEN测试可在临床「正常」听力范围内观察到感音神经性听力缺陷。
- TEN测试中处于「通过」与「失败」之间的结果主要由非内毛细胞相关过程主导。
- 针对内毛细胞相关功能的TEN测试应仅考虑其原始设计功能,即给出通过或失败的二元判断。
研究设计与样本
- 研究纳入112名(71名女性)经听力学筛查为感音神经性听力损失、分类为正常或轻度的参与者,年龄范围32至74岁。
- 在0.75、1、3、4 kHz四个频率及高于各频率纯音绝对阈值12和24 dB两个感觉级进行TEN测试。
- 测试频率选择位于2至6 kHz噪声性听力损失听力学切迹区域之外或之内。
- 累积噪声暴露采用噪声暴露结构化访谈(NESI)评估,NESI要素亦允许按音乐经验对参与者分层。
主要发现
- 在所有频率和测试级下,TEN阈值升高与绝对阈值之间呈强正相关。
- 在排除噪声暴露和音乐经验因素后,这些相关性变化很小。
- 这些相关性在「正常」听力范围(绝对阈值≤15 dB HL)内仍可观察到。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The threshold equalizing noise (TEN(HL)) is a clinically administered test to detect cochlear "dead regions" (i.e., regions of loss of inner hair cell [IHC] connectivity), using a "pass/fail" criterion based on the degree of elevation of a masked threshold in a tone-detection task. With sensorineural hearing loss, some elevation of the masked threshold is commonly observed but usually insufficient to create a "fail" diagnosis. The experiment reported here investigated whether the gray area between pass and fail contained information that correlated with factors such as age or cumulative high-level noise exposure (>100 dBA sound pressure levels), possibly indicative of damage to cochlear structures other than the more commonly implicated outer hair cells. DESIGN: One hundred and twelve participants (71 female) who underwent audiometric screening for a sensorineural hearing loss, classified as either normal or mild, were recruited. Their age range was 32 to 74 years. They were administered the TEN test at four frequencies, 0.75, 1, 3, and 4 kHz, and at two sensation levels, 12 and 24 dB above their pure-tone absolute threshold at each frequency. The test frequencies were chosen to lie either distinctly away from, or within, the 2 to 6 kHz region where noise-induced hearing loss is first clinically observed as a notch in the audiogram. Cumulative noise exposure was assessed by the Noise Exposure Structured Interview (NESI). Elements of the NESI also permitted participant stratification by music experience. RESULTS: Across all frequencies and testing levels, a strong positive correlation was observed between elevation of TEN threshold and absolute threshold. These correlations were little-changed even after noise exposure and music experience were factored out. The correlations were observed even within the range of "normal" hearing (absolute thresholds ≤15 dB HL). CONCLUSIONS: Using a clinical test, sensorineural hearing deficits were observable even within the range of clinically "normal" hearing. Results from the TEN test residing between "pass" and "fail" are dominated by processes not related to IHCs. The TEN test for IHC-related function should therefore only be considered for its originally designed function, to generate a binary decision, either pass or fail.
引用
- Stone MA, Perugia E, Bakay W, et al. Threshold Equalizing Noise Test Reveals Suprathreshold Loss of Hearing Function, Even in the "Normal" Audiogram Range. Ear Hear. 2022. PMID: 35276701. doi:10.1097/AUD.0000000000001175
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。