单侧聋人工耳蜗使用者的声源定位长期改善
这项前瞻性重复测量研究纳入20例单侧聋成人人工耳蜗使用者,每年评估声源定位。线性混合模型显示术后长期定位能力优于术前(P < .001),且术后1至5年间仍有显著改善(P = .009)。完成1年和5年随访的11例亚组在均方根误差(P = .020)和变异误差(P = .031)上显著改善。
要点
- 单侧聋成人人工耳蜗使用者在开机后数周内声源定位即显著改善。
- 长期使用人工耳蜗后声源定位能力持续改善,1至5年间仍见显著提高(P = .009)。
- 完成1年和5年随访的11例亚组均方根误差(P = .020)和变异误差(P = .031)显著改善。
核心结论
- 成人单侧聋伴对侧正常听力的CI+NH使用者在最初数周聆听体验内声源定位显著改善,长期使用后还观察到额外改善。
- 本样本在1年与5年随访之间显示显著改善,反应模式准确性和一致性均提高。
研究设计与样本
- 前瞻性重复测量研究,参与者来自一项探讨成人单侧聋CI使用结局的前瞻性临床试验的CI+NH听者样本(n = 20)。
- 在临床试验终点(开机后1年)之后每年评估声源定位,测试为180°弧上11个扬声器随机呈现不同强度宽带噪声脉冲,以均方根(RMS)误差量化表现。
主要发现
- 线性混合模型显示,与术前能力相比,开机后长期CI使用的定位表现更优(P < .001)。
- 长期开机后时期(1-5年)声源定位出现显著改善(P = .009)。
- 完成1年和5年访视的11例参与者亚组均方根误差显著改善(P = .020),变异误差显著改善(P = .031),表明5年访视时反应更一致。
局限性
- 证据等级为3级。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES/HYPOTHESIS: To assess whether early, significant improvements in sound source localization observed in cochlear implant (CI) recipients with normal hearing (NH) in the contralateral ear are maintained after 5 years of CI use. STUDY DESIGN: Prospective, repeated measures study. METHODS: Participants were recruited from a sample of CI + NH listeners (n = 20) who received their device as part of a prospective clinical trial investigating outcomes of CI use for adult cases of single-sided deafness. Sound source localization was assessed annually after the clinical trial endpoint (1-year post-activation). Listeners were asked to indicate the perceived sound source for a broadband noise burst presented randomly at varied intensity levels from one of 11 speakers along a 180° arc. Performance was quantified as root-mean-squared (RMS) error. RESULTS: Linear mixed models showed superior post-activation performance was maintained with long-term CI use as compared to preoperative abilities (P < .001). Unexpectedly, a significant improvement (P = .009) in sound source localization was observed over the long-term post-activation period (1-5 years). To better understand these long-term findings, the response patterns for the 11 participants who were evaluated at the 1- and 5-year visits were reviewed. This subgroup demonstrated a significant improvement in RMS error (P = .020) and variable error (P = .031), indicating more consistent responses at the 5-year visit. CONCLUSION: Adult CI + NH listeners experience significant improvements in sound source localization within the initial weeks of listening experience, with additional improvements observed after long-term device use. The present sample demonstrated significant improvements between the 1-year and 5-year visits, with greater accuracy and consistency noted in their response patterns. LEVEL OF EVIDENCE: 3 Laryngoscope, 132:2453-2458, 2022.
引用
- Thompson NJ, Dillon MT, Buss E, et al. Long-Term Improvement in Localization for Cochlear Implant Users with Single-Sided Deafness. Laryngoscope. 2022. PMID: 35174886. doi:10.1002/lary.30065