基于解剖的人工耳蜗频率分配:耳蜗覆盖的重要性

Anatomy-Based Frequency Allocation in Cochlear Implantation: The Importance of Cochlear Coverage.
PubMed 文献 · Laryngoscope · 2021-12-30

本研究回顾性分析102例患者169只植入耳的CT图像,利用手术规划软件按电极类型和柯替器长度计算基于解剖的频率分配,并与默认标准频率比较。结果显示各电极基于解剖的频率分配均显著高于默认频率,频率-位置失配与耳蜗覆盖负相关、与耳蜗管长度正相关,主要受耳蜗覆盖影响。

要点

  • 基于解剖的频率分配在各电极均显著高于默认频率(单样本t检验,P < .001)。
  • 频率-位置失配与耳蜗覆盖呈负相关,与耳蜗管长度呈正相关(Pearson相关系数 > 0.65,P < .003)。
  • 两名评估者读数同质性好,Cronbach's alpha为0.98。

核心结论

  • 各电极基于解剖的频率分配与默认频率设置显著不同,频率-位置失配主要受耳蜗覆盖影响。

研究设计与样本

  • 回顾性研究,纳入在三级转诊中心接受人工耳蜗植入的患者,排除先天性或获得性耳蜗解剖异常者,共分析102例患者169只植入耳。

主要发现

  • 电极1的基于解剖频率分配均值为487.3 ± 202.9 Hz,电极12为9,298.6 ± 490.6 Hz。
  • 各对应电极的基于解剖频率分配均显著高于默认频率(单样本t检验,P < .001)。
  • 频率-位置失配(单位:半音)与耳蜗覆盖呈负相关,与耳蜗管长度呈正相关(Pearson相关系数 > 0.65,P < .003)。
  • 两名评估者读数同质,Cronbach's alpha为0.98。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES/HYPOTHESIS: This study aimed to compare the predicted anatomy-based frequency allocation of cochlear implant electrodes with the default standard frequencies. STUDY DESIGN: Retrospective study. METHODS: A retrospective analysis was performed using computed tomography (CT) images of patients who received cochlear implants at a tertiary referral center. Patients were excluded if they had any congenital or acquired cochlear anatomical anomalies. The CT images of the patients were uploaded to the surgical planning software. Two independent reviewers allocated the anatomical parameters of the cochlea. The software then used these parameters to calculate the frequency allocation for each electrode according to the type of electrode and the length of the organ of Corti (OC) in each patient. These anatomy-based frequency allocations were compared with the default frequency settings. MAIN OUTCOME MEASURE: Frequency-to-place mismatch in semitones. RESULTS: A total of 169 implanted ears in 102 patients were included in this study. The readings of the two reviewers were homogenous, with a Cronbach's alpha of 0.98. The mean anatomy-based frequency allocation was 487.3 ± 202.9 Hz in electrode 1; 9,298.6 ± 490.6 Hz in electrode 12. The anatomy-based frequency allocations were found to be significantly higher than the frequencies of the default frequencies for each corresponding electrode (one-sample t-test, P < .001). The frequency-to-place mismatch was negatively correlated with cochlear coverage and positively correlated with the cochlear duct length (Pearson correlation > 0.65, P < .003). CONCLUSIONS: The anatomy-based frequency allocation of each electrode is significantly different from the default frequency setting. This frequency-to-place mismatch was affected mainly by the cochlear coverage. LEVEL OF EVIDENCE: 3 Laryngoscope, 132:2224-2231, 2022.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. Aljazeeri I, Hamed N, Abdelsamad Y, et al. Anatomy-Based Frequency Allocation in Cochlear Implantation: The Importance of Cochlear Coverage. Laryngoscope. 2021. PMID: 34967457. doi:10.1002/lary.30004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。