人工耳蜗植入后声学听力变化的时间规律
这项前瞻性单受试者研究纳入211例接受保听力人工耳蜗植入者,分析低频纯音听阈变化。长期保听力率因设备而异,听力损失与设备类型或性别无关;年龄≥65岁者初始开机后听力结局较年轻者差(P=0.0262),但听力下降速率无显著差异(P=0.0938),早期听力损失不预测长期下降速率。
要点
- 长期低频保听力率因设备类型不同,L24为65%(52/80),Flex为84%(16/19)。
- 听力损失与设备类型(P=0.9105)或性别(P=0.2169)无关。
- 年龄≥65岁者初始开机后听力结局较年龄<65岁者差(P=0.0262)。
核心结论
- 长期低频保听力对人工耳蜗植入者可行,且与性别或设备类型无关。
- 听力随时间下降的速率不取决于患者年龄。
- 人工耳蜗植入后早期听力损失不预测长期听力损失的速率。
研究设计与样本
- 前瞻性单受试者研究,纳入211例接受保听力人工耳蜗植入的受试者,其中127例纳入后续分析。
- 设备分布:80例Nucleus Hybrid L24(Cochlear)、47例422/522(Cochlear)、24例S8(Cochlear)、14例S12(Cochlear)、6例SRW(Cochlear)、21例SLIM J(Advanced Bionics)、19例Flex(Med-EL)。
- 收集并比较术前与术后的低频纯音平均听阈。
主要发现
- 长期保听力率:L24为65%(52/80),S8为83%(20/24),S12为79%(11/14),SRW为83%(5/6),422/522为54%(25/47),SLIM J为91%(21/23),Flex为84%(16/19)。
- 听力损失与设备类型无关(P=0.9105),与性别无关(P=0.2169)。
- 年龄≥65岁受试者初始设备激活后听力结局较年龄<65岁受试者差(P=0.0262)。
- 年龄≥65岁与年龄<65岁患者听力损失速率无显著差异(P=0.0938)。
- 术后初始听力损失与长期听力损失速率无关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES/HYPOTHESIS: To determine the timing of acoustic hearing changes among hearing preservation Cochlear implant (CI) recipients. To determine differences in hearing outcomes based on device type and demographic factors. To determine if there is a relationship between the extent of early hearing loss after CI and the subsequent rate of continued hearing loss. STUDY DESIGN: Prospective, single subject study. METHODS: Two hundred and eleven subjects who received a hearing preservation CI were included in the study-80 Nucleus Hybrid L24 (Cochlear), 47 422/522 (Cochlear), 24 S8 (Cochlear), 14 S12 (Cochlear), 6 SRW (Cochlear), 21 SLIM J (Advanced Bionics), and 19 Flex (Med-EL). Of these, 127 were included in the subsequent analyses. Audiometric thresholds (low frequency pure-tone-averages) were collected and compared pre and postoperatively. RESULTS: Long-term hearing preservation rates were 65% (52/80) for L24, 83% (20/24) for S8, 79% (11/14) for S12, 83% (5/6) for SRW, 54% (25/47) for 422/522, 91% (21/23) for SLIM J, and 84% (16/19) for Flex. Hearing loss was not related to device type (P = .9105) or gender (P = .2169). Older subjects (age ≥65) had worse hearing outcomes than younger subjects after initial device activation (age <65, P = .0262). There was no significant difference in rate of hearing loss over time between older and younger patients (P = .0938). Initial postoperative hearing loss was not associated with the rate of long-term hearing loss. CONCLUSIONS: Long-term low frequency hearing preservation is possible for CI recipients and is not associated with gender or device type. Rate of hearing loss over time is not dependent on patient age. Early hearing loss after CI does not predict the rate of long-term hearing loss. LEVEL OF EVIDENCE: 3 Laryngoscope, 132:2036-2043, 2022.
引用
- Jensen MJ, Isaac H, Hernandez H, et al. Timing of Acoustic Hearing Changes After Cochlear Implantation. Laryngoscope. 2021. PMID: 34882792. doi:10.1002/lary.29984
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。