伴周边小球的黑素细胞病变:154例高危黑色素瘤患者数字皮肤镜随访联合反射式共聚焦显微镜的前瞻性观察研究
研究前瞻性纳入154例数字皮肤镜随访患者的伴周边小球黑素细胞病变(MLPG),均行皮肤镜和反射式共聚焦显微镜(RCM)评估并切除活检。结果显示直径≥6 mm、双轴不对称、新发病灶且周边小球周径<25%、周边小球大小形状不规则及RCM致密不规则巢与黑色素瘤相关;皮肤镜联合RCM诊断黑色素瘤的准确率为100%,与组织病理学的一致性kappa系数为0.76。
要点
- MLPG直径≥6 mm且双轴不对称与黑色素瘤相关(P=0.01,P=0.003)。
- 新发病灶周边小球周径<25%提示恶性(P=0.010)。
- 皮肤镜联合RCM诊断黑色素瘤准确率100%,与病理一致性kappa=0.76。
核心结论
- 推荐切除具有双轴不对称、直径≥6 mm、新发病灶周边小球周径<25%、周边小球大小形状不规则或RCM致密不规则巢的MLPG,不论患者年龄。
研究设计与样本
- 前瞻性观察研究,24个月内纳入154例数字皮肤镜随访患者(平均年龄42.45岁,范围18.78-73.19),所有MLPG均行皮肤镜和RCM评估并切除行组织病理学检查。
主要发现
- 共诊断3例黑色素瘤和19例发育不良痣(DNs),患者年龄无显著差异(P=0.662)。
- MLPG直径≥6 mm和双轴不对称与黑色素瘤相关(P=0.01,P=0.003)。
- 拥有超过一个MLPG的患者患黑色素瘤的可能性更低。
- 黑色素瘤中蓝灰色和红色更常见(P=0.013和P=0.000)。
- 周边小球大小和形状不同与DNs和黑色素瘤相关(P=0.000和P=0.001)。
关键数值与推荐
- 推荐切除双轴不对称的MLPG。
- 推荐切除直径≥6 mm的MLPG。
- 推荐切除新发病灶中周边小球周径<25%的MLPG。
- 推荐切除周边小球大小和形状不规则的MLPG。
- 推荐切除RCM显示致密不规则巢的MLPG。
临床怎么用
- 在高危黑色素瘤患者的MLPG管理中,应结合皮肤镜和RCM评估,对具有上述危险特征的病变及时切除,不论患者年龄。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The management of melanocytic lesions with peripheral globules (MLPGs) is usually age-dependent and can be challenging in high-risk melanoma patients. OBJECTIVES: To evaluate clinical, dermoscopic and reflectance confocal microscopy (RCM) features of MLPG in patients under digital dermoscopic surveillance. To know whether dermoscopic or RCM findings correlate with histologic diagnosis and the accuracy of the dermoscopy-RCM compared with histopathology. METHODS: During 24 months, we prospectively enrolled MLPG in patients under digital dermoscopy follow-up. All were evaluated by dermoscopy and RCM and excised for histologic examination. RESULTS: We enrolled 154 patients, mean age 42.45 years (18.78-73.19). Three melanomas and 19 dysplastic naevi (DNs) were diagnosed. There were no significant differences in the age of the patients (P = 0.662). MLPGs with diameter of 6 mm or more and asymmetry in two axes were associated with melanoma (P = 0.01, P = 0.003). Patients with more than one MLPG were less likely to have melanoma. Blue-grey and red colours were more frequent in melanoma (P = 0.013 and P = 0.000). Different sizes and shapes of PG were associated with DN and melanoma (P = 0.000 and P = 0.001). In a new lesion, PG in <25% of the circumference was related to malignancy (P = 0.010). RCM signs of malignancy were related to melanoma: pagetoid cells (P = 0.000), non-edged papillae (P = 0.001), atypical junctional thickenings (P = 0.000) and atypical cells at the dermal-epidermal junction (P = 0.000). Dense irregular nests were associated to melanoma (P = 0.019). Dermoscopy and confocal evaluation were able to diagnose 100% of melanomas and 84.21% of DNs. The kappa coefficient between dermoscopy-RCM vs. histology was 0.76. CONCLUSIONS: We recommend to excise a MLPG when it presents asymmetry in two axes, 6 or more mm, new lesion with PG in less than the 25% of the circumference, irregular size and shape PGs and irregular dense nests on RCM, regardless of the patient's age.
引用
- Pampín-Franco A, Gamo-Villegas R, Floristán-Muruzábal U, et al. Melanocytic lesions with peripheral globules: results of an observational prospective study in 154 high-risk melanoma patients under digital dermoscopy follow-up evaluated with reflectance confocal microscopy. J Eur Acad Dermatol Venereol. 2021. PMID: 33428272. doi:10.1111/jdv.17105
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。