文献速递皮肤肿瘤

三维宽场多光谱光声成像用于人黑色素瘤在体测量:一项初步研究

3D wide-field multispectral photoacoustic imaging of human melanomas in vivo: a pilot study.
PubMed 文献 · J Eur Acad Dermatol Venereol · 2020-12-05

该初步研究纳入6例黑色素瘤患者,使用三维多光谱光声成像系统在体检测,对其中5例计算光谱解混后的光声深度并与组织病理深度比较。结果显示平均绝对误差为0.36 mm,并可显示转移性黑色素瘤的滋养血管,提示该技术有助于术前评估深度与边界。

要点

  • 光声深度与病理深度平均绝对误差0.36 mm
  • 原位与结节型黑色素瘤测得最小和最大深度分别为0.6和9.1 mm
  • 可显示转移性黑色素瘤的滋养血管

核心结论

  • 三维多光谱光声成像可测量不同类型黑色素瘤的深度和大小,并可显示转移性黑色素瘤的血管。

研究设计与样本

  • 初步研究,在体检查6例黑色素瘤患者,使用三维多光谱光声成像系统。
  • 对5例黑色素瘤(1例原位、3例结节型、1例肢端雀斑样型)计算光谱解混后的光声深度并与组织病理深度比较。

主要发现

  • 光谱解混后的光声深度与组织病理深度匹配良好,平均绝对误差为0.36 mm。
  • 原位和结节型黑色素瘤测得的最小和最大深度分别为0.6 mm和9.1 mm。
  • 1例转移性黑色素瘤的三维光声图像中可见滋养血管,提示肿瘤周围新生血管形成。

临床怎么用

  • 术前获取黑色素瘤的准确深度和边界信息可能有助于手术完整切除。

局限性

  • 本研究为初步研究,样本量小(6例患者,5例进行深度比较)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The Breslow depth is an important parameter to determine the excision margin and prognosis of melanoma. However, it is difficult to accurately determine the actual Breslow depth before surgery using the existing ocular micrometer and biopsy technique. OBJECTIVES: To evaluate the use of 3D wide-field multispectral photoacoustic imaging to non-invasively measure depth and outline the boundary of melanomas for optimal surgical margin selection. METHODS: Six melanoma patients were examined in vivo using the 3D multispectral photoacoustic imaging system. For five cases of melanomas (one in situ, three nodular, and one acral lentiginous type melanoma), the spectrally unmixed photoacoustic depths were calculated and compared against histopathological depths. RESULTS: Spectrally unmixed photoacoustic depths and histopathological depths match well within a mean absolute error of 0.36 mm. In particular, the measured minimum and maximum depths in the in situ and nodular type of melanoma were 0.6 and 9.1 mm, respectively. In the 3D photoacoustic image of one metastatic melanoma, feeding vessels were visualized in the melanoma, suggesting the neovascularization around the tumour. CONCLUSIONS: The 3D multispectral photoacoustic imaging not only provides well-measured depth and sizes of various types of melanomas, it also visualizes the metastatic type of melanoma. Obtaining accurate depth and boundary information of melanoma before surgery would play a useful role in the complete excision of melanoma during surgery.

来源:J Eur Acad Dermatol Venereol,查看原文。版权归原作者所有。

引用

  1. Park B, Bang CH, Lee C, et al. 3D wide-field multispectral photoacoustic imaging of human melanomas in vivo: a pilot study. J Eur Acad Dermatol Venereol. 2020. PMID: 33037671. doi:10.1111/jdv.16985

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。