文献速递皮肤肿瘤

基底细胞癌及皮肤对高剂量电离辐射反应的活体成像特征:一项前瞻性研究

In vivo imaging characterization of basal cell carcinoma and cutaneous response to high-dose ionizing radiation therapy: A prospective study of reflectance confocal microscopy, dermoscopy, and ultrasonography.
PubMed 文献 · J Am Acad Dermatol · 2020-08-20

该前瞻性研究纳入12例活检证实的基底细胞癌患者,接受42 Gy分6次近距离放射治疗,在治疗前及治疗后6周、3个月、12个月进行皮肤镜、高频超声和反射式共聚焦显微镜成像。结果显示反射式共聚焦显微镜在表征基底细胞癌放疗反应方面比皮肤镜和高频超声更可靠,平均随访31.7个月未见复发。

要点

  • 反射式共聚焦显微镜比皮肤镜和高频超声更可靠地表征基底细胞癌放疗反应。
  • 放疗后反射式共聚焦显微镜特征消退率达91.7%,高频超声达100%。
  • 平均随访31.7个月未见复发。

核心结论

  • 反射式共聚焦显微镜在表征基底细胞癌放疗反应方面比皮肤镜和高频超声更可靠。

研究设计与样本

  • 前瞻性研究,纳入12例活检证实的基底细胞癌患者,2014年至2018年进行。
  • 患者接受42 Gy分6次近距离放射治疗。
  • 在治疗前及治疗后6周、3个月、12个月进行皮肤镜、高频超声和反射式共聚焦显微镜成像。

主要发现

  • 共完成137次成像评估(反射式共聚焦显微镜+皮肤镜+高频超声),涉及12例患者。
  • 治疗前,皮肤镜、反射式共聚焦显微镜和高频超声分别有81.8%、91%和17%的患者存在基底细胞癌特异性特征。
  • 治疗后,相应成像模态的特征消退率分别为33.4%、91.7%和100%。
  • 平均随访31.7个月未见复发。

临床怎么用

  • 反射式共聚焦显微镜可作为评估基底细胞癌放疗反应的无创工具。

局限性

  • 样本量小。
  • 无组织病理学对照。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Radiation therapy (RT) is a treatment option for select skin cancers. The histologic effects of RT on normal skin or skin cancers are not well characterized. Dermoscopy, high-frequency ultrasonography (HFUS), and reflectance confocal microscopy (RCM) are noninvasive imaging modalities that may help characterize RT response. OBJECTIVES: To describe changes in the tumor and surrounding skin of patients with basal cell carcinoma (BCC) treated with RT. METHODS: The study was conducted between 2014 and 2018. Patients with biopsy-proven BCCs were treated with 42 Gy in 6 fractions using a commercially available brachytherapy device. Dermoscopy, HFUS, and RCM were performed before treatment and at 6 weeks, 3 months, and 12 months after RT. RESULTS: A total of 137 imaging assessments (RCM + dermoscopy + HFUS) were performed in 12 patients. BCC-specific features were present in 81.8%, 91%, and 17% of patients imaged with dermoscopy, RCM, and HFUS at baseline, respectively, before treatment. After treatment, the resolution of these features was noted in 33.4%, 91.7%, and 100% of patients imaged with the respective modalities. No recurrences were seen after a mean of 31.7 months of follow-up. LIMITATIONS: Small sample size and no histopathologic correlation. CONCLUSION: Dermoscopy and HFUS were not as reliable as RCM at characterizing BCC RT response.

来源:J Am Acad Dermatol,查看原文。版权归原作者所有。

引用

  1. Navarrete-Dechent C, Cordova M, Liopyris K, et al. In vivo imaging characterization of basal cell carcinoma and cutaneous response to high-dose ionizing radiation therapy: A prospective study of reflectance confocal microscopy, dermoscopy, and ultrasonography. J Am Acad Dermatol. 2020. PMID: 32827607. doi:10.1016/j.jaad.2020.07.130

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。